Daikin split system air conditioner code AH: Streamer unit fault
Split system air conditioner, Australia
The Streamer unit inside the indoor unit has developed a fault.
This needs a licensed air conditioning technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
Only some models show this code. Check the list below.
What causes it
-
The Streamer unit or its wiring has failed. A licensed technician must diagnose it.
How to read this code on your unit
A fault shows as a blinking lamp on the indoor unit, the OPERATION lamp on most models or the multi-monitor lamp on Zena FTXJ-PVMA. To read the code, point the remote at the indoor unit and hold its Cancel button for about 5 seconds, until 00 blinks in the temperature display section. Then press Cancel again and again until the remote answers with a long beep; the code in the temperature display at that moment is the stored fault. A short beep means the code on show is not a stored fault. To clear the display, hold Cancel for 5 seconds, or leave the remote untouched for a minute. The manuals say a fault must be handled by a licensed installer or the dealer, so write the code down before you call.
Booking a licensed air conditioning technician
Book a licensed air conditioning technicianlicensed air conditioning technician
- Do not open any panels. Refrigerant circuits must only be opened by a licensed technician.
- Note the code, which unit shows it (indoor or outdoor), and the model numbers of both units.
- Book a licensed air conditioning technician and give them those details.
Models that show this code
16 models in 2 ranges
| Range | Models |
|---|---|
| Zena FTXJ-T2VMA | FTXJ25T2VMAW, FTXJ35T2VMAW, FTXJ50T2VMAW, FTXJ60T2VMAW, FTXJ25T2VMAK, FTXJ35T2VMAK, FTXJ50T2VMAK, FTXJ60T2VMAK |
| Zena FTXJ-TVMA | FTXJ25TVMAW, FTXJ35TVMAW, FTXJ50TVMAW, FTXJ60TVMAW, FTXJ25TVMAK, FTXJ35TVMAK, FTXJ50TVMAK, FTXJ60TVMAK |
Where this comes from
- Zena FTXJ25-60TVMA operation manual (3P524249-1) , page 23
- Zena FTXJ25-60T2VMA operation manual (3P705032-1) , page 23
Checked against the manufacturer's manual on 17 October 2026.
Other Daikin split system air conditioner codes
| Code | Meaning | What you can do |
|---|---|---|
| A1 | Indoor unit circuit board fault | Call a pro |
| A5 | Freeze-up or high-pressure protection tripped | Call a pro |
| A6 | Indoor fan motor fault | Call a pro |
| C4 | Indoor coil temperature sensor fault | Call a pro |
| C7 | Front panel will not open or close | You can often fix it |
| C9 | Room temperature sensor fault | Call a pro |
| CC | Humidity sensor fault | Call a pro |
| E1 | Outdoor unit circuit board fault | Call a pro |
| E5 | Compressor overload cutout | Call a pro |
| E8 | Mains input overcurrent | Call a pro |
| EA | Cooling-heating changeover fault | Call a pro |
| L5 | Inverter output overcurrent | Call a pro |