Daikin split system air conditioner code H8: DC current or voltage sensor fault

Split system air conditioner, Australia

The sensor watching the unit's DC current or voltage is not working properly.

This needs a licensed air conditioning technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

What causes it

  1. The DC current or voltage sensor circuit has failed. A licensed technician must diagnose it.

    Book a licensed air conditioning technician

How to read this code on your unit

A fault shows as a blinking lamp on the indoor unit, the OPERATION lamp on most models or the multi-monitor lamp on Zena FTXJ-PVMA. To read the code, point the remote at the indoor unit and hold its Cancel button for about 5 seconds, until 00 blinks in the temperature display section. Then press Cancel again and again until the remote answers with a long beep; the code in the temperature display at that moment is the stored fault. A short beep means the code on show is not a stored fault. To clear the display, hold Cancel for 5 seconds, or leave the remote untouched for a minute. The manuals say a fault must be handled by a licensed installer or the dealer, so write the code down before you call.

Booking a licensed air conditioning technician

Book a licensed air conditioning technicianlicensed air conditioning technician

  1. Do not open any panels. Refrigerant circuits must only be opened by a licensed technician.
  2. Note the code, which unit shows it (indoor or outdoor), and the model numbers of both units.
  3. Book a licensed air conditioning technician and give them those details.

Models that show this code

167 models in 21 ranges
RangeModels
Alira FTXM-UVMAFTXM20UVMA, FTXM25UVMA, FTXM35UVMA, FTXM46UVMA, FTXM50UVMA, FTXM60UVMA, FTXM71UVMA
Alira X FTXM-W1VMAFTXM20W1VMA, FTXM25W1VMA, FTXM35W1VMA, FTXM46W1VMA, FTXM50W1VMA, FTXM60W1VMA, FTXM71W1VMA
Alira X FTXM/FTKM-W2VMAFTXM20W2VMA, FTXM25W2VMA, FTXM35W2VMA, FTXM46W2VMA, FTXM50W2VMA, FTXM60W2VMA, FTXM71W2VMA, FTKM20W2VMA, FTKM25W2VMA, FTKM35W2VMA, FTKM46W2VMA, FTKM50W2VMA, FTKM60W2VMA, FTKM71W2VMA
Alira X FTXM/FTKM-WVMAFTXM20WVMA, FTXM25WVMA, FTXM35WVMA, FTXM46WVMA, FTXM50WVMA, FTXM60WVMA, FTXM71WVMA, FTKM20WVMA, FTKM25WVMA, FTKM35WVMA, FTKM46WVMA, FTKM50WVMA, FTKM60WVMA, FTKM71WVMA
Cora FTKM-Q2VMAFTKM20Q2VMA, FTKM25Q2VMA, FTKM35Q2VMA, FTKM46Q2VMA, FTKM50Q2VMA, FTKM60Q2VMA, FTKM71Q2VMA
Cora FTXM/FTKM-QVMA and FTXM-PVMAFTXM20QVMA, FTXM25QVMA, FTXM35QVMA, FTXM46QVMA, FTXM50QVMA, FTXM60QVMA, FTXM71QVMA, FTKM20QVMA, FTKM25QVMA, FTKM35QVMA, FTKM46QVMA, FTKM50QVMA, FTKM60QVMA, FTKM71QVMA, FTXM85PVMA, FTXM95PVMA
Cora FTXV-UVMAFTXV20UVMA, FTXV25UVMA, FTXV35UVMA, FTXV46UVMA, FTXV50UVMA, FTXV60UVMA, FTXV71UVMA
Cora FTXV-W1VMAFTXV20W1VMA, FTXV25W1VMA, FTXV35W1VMA, FTXV46W1VMA, FTXV50W1VMA, FTXV60W1VMA, FTXV71W1VMA
Cora FTXV-W2VMAFTXV20W2VMA, FTXV25W2VMA, FTXV35W2VMA, FTXV46W2VMA, FTXV50W2VMA, FTXV60W2VMA, FTXV71W2VMA
Cora FTXV-WVMAFTXV20WVMA, FTXV25WVMA, FTXV35WVMA, FTXV46WVMA, FTXV50WVMA, FTXV60WVMA, FTXV71WVMA
Lite FTKF-T2VMAFTKF20T2VMA, FTKF25T2VMA, FTKF35T2VMA, FTKF46T2VMA, FTKF50T2VMA, FTKF60T2VMA, FTKF71T2VMA
Lite FTKF-TVMAFTKF20TVMA, FTKF25TVMA, FTKF35TVMA, FTKF46TVMA, FTKF50TVMA, FTKF60TVMA, FTKF71TVMA
Lite FTXF-TVMAFTXF20TVMA, FTXF25TVMA, FTXF35TVMA, FTXF46TVMA, FTXF50TVMA, FTXF60TVMA, FTXF71TVMA
Lite FTXF-W1VMAFTXF20W1VMA, FTXF25W1VMA, FTXF35W1VMA, FTXF46W1VMA, FTXF50W1VMA, FTXF60W1VMA, FTXF71W1VMA
Lite FTXF-W2VMAFTXF20W2VMA, FTXF25W2VMA, FTXF35W2VMA, FTXF46W2VMA, FTXF50W2VMA, FTXF60W2VMA, FTXF71W2VMA
Lite FTXF-WVMAFTXF20WVMA, FTXF25WVMA, FTXF35WVMA, FTXF46WVMA, FTXF50WVMA, FTXF60WVMA, FTXF71WVMA
XL 85/95 P2VMA/L2VMAFTXM85P2VMA, FTXM95P2VMA, FTXV85L2VMA, FTXV95L2VMA
XL 85/95 PAVMA/LVMAFTXM85PAVMA, FTXM95PAVMA, FTKM85PAVMA, FTKM95PAVMA, FTXV85LVMA, FTXV95LVMA
Zena FTXJ-PVMAFTXJ25PVMAW, FTXJ35PVMAW, FTXJ50PVMAW, FTXJ25PVMAS, FTXJ35PVMAS, FTXJ50PVMAS
Zena FTXJ-T2VMAFTXJ25T2VMAW, FTXJ35T2VMAW, FTXJ50T2VMAW, FTXJ60T2VMAW, FTXJ25T2VMAK, FTXJ35T2VMAK, FTXJ50T2VMAK, FTXJ60T2VMAK
Zena FTXJ-TVMAFTXJ25TVMAW, FTXJ35TVMAW, FTXJ50TVMAW, FTXJ60TVMAW, FTXJ25TVMAK, FTXJ35TVMAK, FTXJ50TVMAK, FTXJ60TVMAK

Where this comes from

Checked against the manufacturer's manual on 17 October 2026.

Report a mistake on this page

Other Daikin split system air conditioner codes

Code Meaning What you can do
CC Humidity sensor fault Call a pro
EA Cooling-heating changeover fault Call a pro
F3 Compressor discharge too hot Call a pro
F6 High-pressure protection in cooling Call a pro
F8 Compressor overheated and stopped Call a pro
H0 Compressor sensor circuit fault Call a pro
H6 Position detection sensor fault Call a pro
H9 Outdoor air temperature sensor fault Call a pro
J3 Discharge pipe sensor fault Call a pro
J6 Outdoor coil temperature sensor fault Call a pro
J8 Liquid pipe sensor fault Call a pro
L3 Electrical parts overheating Call a pro