Goodman gas furnace 3 red flashes: Pressure switch not closing
Gas furnace, Canada and United States
The inducer is running but the pressure switch does not close, so the burners do not light. The inducer keeps running with no further furnace operation.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the flue or exhaust. A blocked or leaking flue can let carbon monoxide into the home.
What causes it
GMS8, GMH8, GMSS9, GMH95 and GKS9 boards
-
The pressure switch hose is blocked, pinched or connected wrongly.
-
The flue, chimney or (on high-efficiency models) the combustion air pipe is blocked, or the inducer is weak.
-
On GMSS9, GMH95 and GKS9 condensing furnaces, the condensate drain system is blocked. The drain and trap are serviced by a qualified servicer.
-
The pressure switch has the wrong setpoint or its contacts are faulty.
-
Loose or wrongly connected wiring.
-
On GMS8, GMH8, GDS8 and GDH8 furnaces fitted with a masonry vent kit, the kit's manual reset limit switch has opened, or the masonry chimney or flue is blocked.
GMES80, GMES92 and GMES96 boards
-
The pressure switch hose is blocked, pinched or connected wrongly.
-
The flue is blocked or the inducer is weak.
-
The pressure switch has the wrong setpoint or its contacts are faulty.
-
Loose or wrongly connected wiring.
GMEC96 three-colour light
-
A faulty pressure switch.
-
A problem with the pressure switch tubing, wiring or connections.
-
The inducer relay on the control board has failed.
-
The vent or intake pipe is blocked or restricted, for example at the outside termination, or has too many elbows or too much length.
Check the outside flue or vent terminal is clearYou can do this
- Find where the flue or vent pipe ends outside the building. High-efficiency furnaces and some water heaters also have a combustion air intake pipe beside it: check that one too. On some outdoor water heaters the flue outlet is part of the front cover.
- Look for anything blocking it, such as leaves, a bird or insect nest, snow, plants, or items stored against the wall.
- Cut back plants and move stored items away from it. Do not touch, poke into or hose the flue outlet. If something is inside it, book a service. The terminal can be hot. Do not climb onto the roof or use a ladder to reach it; if it is out of reach, book a technician.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
250 models in 12 ranges
| Range | Models |
|---|---|
| GDH8 | GDH80403AN, GDH80403AX, GDH80603AN, GDH80603AX, GDH80804BN, GDH80804BX, GDH81005CN, GDH81005CX |
| GDS8 | GDS80403AN, GDS80403AX, GDS80603AN, GDS80603AX, GDS80804BN, GDS80804BX, GDS81005CN, GDS81005CX |
| GKS9 | GKS90453BX, GKS90703BX, GKS90704CX, GKS90904CX, GKS90905DX, GKS91155DX |
| GMH8 / AMH8 | GMH80403AN, GMH80403AX, GMH80603AN, GMH80603AX, GMH80604BN, GMH80604BX, GMH80803BN, GMH80803BX, GMH80804BN, GMH80804BX, GMH80805CN, GMH80805CX, GMH81005CN, GMH81005CX, GMH81205DN, GMH81205DX, GMH81405DN, AMH80403AN, AMH80403AX, AMH80603AN, AMH80603AX, AMH80604BN, AMH80604BX, AMH80803BN, AMH80803BX, AMH80804BN, AMH80804BX, AMH80805CN, AMH80805CX, AMH81005CN, AMH81005CX, AMH81205DN, AMH81205DX, AMH81405DX |
| GMH95 / GCH95 / AMH95 | GMH950453BX, GMH950703BX, GMH950704CX, GMH950904CX, GMH950905CX, GMH950905DX, GMH951155DX, AMH950453BX, AMH950703BX, AMH950704CX, AMH950904CX, AMH950905CX, AMH950905DX, AMH951155DX, GCH950453BX, GCH950703BX, GCH950704CX, GCH950905DX |
| GMS8 / AMS8 | GMS80403AN, GMS80403AX, GMS80603AN, GMS80603AX, GMS80604BN, GMS80604BX, GMS80804BN, GMS80804BX, GMS80805CN, GMS80805CX, GMS81005CN, GMS81005CX, GMS81205DN, GMS81205DX, GMS81405DN, AMS80403AX, AMS80603AX, AMS80604BX, AMS80804BX, AMS80805CX, AMS81005CX, AMS81205DX, AMS81405DN |
| GMSS92 / GCSS92 / AMSS92 | GMSS920402BN, GMSS920403AN, GMSS920603BN, GMSS920803BN, GMSS920804CN, GMSS920805CN, GMSS921004CN, GMSS921005CN, GMSS921205DN, AMSS920402BN, AMSS920403AN, AMSS920603BN, AMSS920803BN, AMSS920804CN, AMSS920805CN, AMSS921004CN, AMSS921005CN, AMSS921205DN, GCSS920402BN, GCSS920603BN, GCSS920804CN, GCSS921005CN |
| GMSS96 / GCSS96 / AMSS96 / ACSS96 | GMSS960402BN, GMSS960403AN, GMSS960603BN, GMSS960803BN, GMSS960804CN, GMSS960805CN, GMSS961005CN, GMSS961205DN, AMSS960402BN, AMSS960403AN, AMSS960603BN, AMSS960803BN, AMSS960804CN, AMSS960805CN, AMSS961005CN, AMSS961205DN, GCSS960402BN, GCSS960603BN, GCSS960804CN, GCSS961005CN, GCSS961205DN, ACSS960402BN, ACSS960603BN, ACSS960804CN, ACSS961005CN, ACSS961205DN |
| GMES80 / GCES80 / AMES80 / ACES80 | GMES800403AN, GMES800403AX, GMES800603AN, GMES800603AX, GMES800603BN, GMES800603BX, GMES800604BN, GMES800604BX, GMES800803BN, GMES800803BX, GMES800804BN, GMES800804BX, GMES800804CN, GMES800804CX, GMES800805CN, GMES800805CX, GMES801005CN, GMES801005CX, GMES801205DN, AMES800403AX, AMES800603AX, AMES800603BN, AMES800604BX, AMES800803BX, AMES800804BX, AMES800804CX, AMES800805CX, AMES801005CX, AMES801205DX, GCES800403AN, GCES800403AX, GCES800603AN, GCES800603AX, GCES800804BN, GCES800804BX, GCES801005CN, GCES801005CX, ACES800403AN, ACES800403AX, ACES800603AN, ACES800603AX, ACES800804BX, ACES801005CX |
| GMES92 | GMES920403AN, GMES920603BN, GMES920803BN, GMES920804CN, GMES920805CN, GMES921004CN, GMES921005CN, GMES921205DN |
| GMES96 / GCES96 / AMES96 / ACES96 | GMES960403AN, GMES960603BN, GMES960803BN, GMES960804CN, GMES960805CN, GMES961005CN, GMES961205DN, AMES960403AN, AMES960603BN, AMES960803BN, AMES960804CN, AMES960805CN, AMES961005CN, AMES961205DN, GCES960403BN, GCES960603BN, GCES960804CN, GCES961005CN, GCES961205DN, ACES960403BN, ACES960603BN, ACES960804CN, ACES961005CN, ACES961205DN |
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
- GMS8/GMH8 gas furnace installation instructions (IO-446F) , page 36
- GMSS92/GMSS96 gas furnace installation instructions (IOG-2009Q) , page 41, 42
- GMH95 gas furnace installation instructions (IO-299R) , page 42
- GKS9 gas furnace installation instructions (IO-300O) , page 35
- GMES80 gas furnace installation instructions (IOG-2021H) , page 29
- GMES92/GMES96 gas furnace installation instructions (IOG-2020J) , page 40
- GMEC96 two-stage gas furnace installation instructions (IOG-2011U) , page 54, 56
- Gas furnace user's information manual (HI-130) , page 8
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| E1 | Low-stage pressure switch closed at start of heating | Call a pro |
| E2 | Low-stage pressure switch not closing | Safe checks first, then a pro |
| E8 | High-stage pressure switch closed at start of heating | Call a pro |
| E9 | High-stage pressure switch not closing | Safe checks first, then a pro |
| EE1 | Pressure switch closed at start of heating | Call a pro |
| EE2 | Pressure switch not closing | Call a pro |
| EE8 | High-stage pressure switch closed at start of heating | Call a pro |
| EE9 | High-stage pressure switch not closing | Call a pro |
| 2 red flashes | Pressure switch closed when it should be open | Call a pro |
| 3 double red flashes | High-stage pressure switch stuck open | Call a pro |
| 6 red flashes | Overheat / flue or venting fault (depends on model) | Depends on your model |
| 12 red flashes | Flue or venting fault / ignition failure (depends on model) | Call a pro |
See all flue or venting fault codes on gas furnaces across brands.