Navien tankless water heater code E438: Circulation pump fault

Tankless water heater, Canada and United States

The circulation pump used for recirculation is not operating normally. Only NPE-A models have a built-in pump.

This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.

What causes it

NPE-A/S first-generation condensing models

  1. A shutoff valve on the water supply or recirculation return line is closed.

    Check the recirculation lines and pump on a Navien water heaterYou can do this

    1. If the heater runs an external recirculation loop, find the supply and return pipes for the loop and check that any shutoff valves on them are fully open.
    2. On NPE-A2 and NPE-S2 models installed with an air handler or a separate circulation pump, check that the pump has power and is running.
    3. On NPE-A models with internal recirculation, the direction of the 2-way valve is a check for your installer.
    4. Reset the heater. If the code comes back with the valves open and the pump powered, book a technician.

    Clear a Navien error codeYou can do this

    1. Deal with the cause first, using the checks listed for the code.
    2. On NPE-A2 and NPE-S2 models, press the Back button on the front panel. On first-generation NPE-A and NPE-S models and on indoor NPN models, press the Reset button on the front panel.
    3. If an NR-21DU remote controller is fitted, you can press its OK button once instead. On outdoor NPN models, which have no front panel, the remote is the way to reset. The remote shows RST when the error is reset.
    4. If the code comes back, stop resetting. Note the code and the model number and contact Navien technical support or a licensed technician.
      Resetting over and over can hide a fault that needs a technician.
  2. With internal recirculation, the 2-way valve may be set to the wrong position. Navien's manual lists checking its direction; leave this check to your installer.

    Book a licensed plumber

  3. If the code returns after the checks above, contact Navien technical support or a qualified technician to investigate the circulation pump.

    Book a licensed gas technician

NPE-A2/S2 condensing models

  1. The circulation pump that serves the air handler is not running properly.

    Same check as above: Check the recirculation lines and pump on a Navien water heater

    Same check as above: Clear a Navien error code

  2. The pump or its wiring has failed. Suspect this when the pump has power and the code comes back.

    Book a licensed gas technician

NPN non-condensing models

  1. With external recirculation, a shutoff valve on the recirculation supply or return line is closed.

    Same check as above: Check the recirculation lines and pump on a Navien water heater

    Same check as above: Clear a Navien error code

  2. The pump or its wiring has failed. Suspect this when the lines are open and the code comes back.

    Book a licensed gas technician

How to read this code on your unit

Booking a licensed gas technician

Contact Navien before booking a repairYou can do this

  1. Have the model number, serial number, purchase date, where the heater is installed and the error code ready.
  2. Call Navien Technical Support on 1-800-519-8794, or contact the company that installed the heater.
  3. For a repair under warranty, the installer or service provider must contact Navien before starting the work.

Book a licensed plumberplumber

  1. Note the code, the model and serial numbers, and what the system was doing when the code appeared.
  2. Book a licensed plumber and give them those details.

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

21 models in 6 ranges
RangeModels
NPE-A (first generation)NPE-180A, NPE-210A, NPE-240A
NPE-S (first generation)NPE-150S, NPE-180S, NPE-210S, NPE-240S
NPE-A2NPE-180A2, NPE-210A2, NPE-240A2
NPE-S2NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2
NPN-ENPN-120E, NPN-160E, NPN-180E, NPN-199E
NPN-UNPN-160U, NPN-180U, NPN-199U

Where this comes from

Checked against the manufacturer's manual on 9 October 2026.

Report a mistake on this page

Other Navien tankless water heater codes

Code Meaning What you can do
E157 Air volume control fault Call a pro
E170 Freeze protection heater fault Call a pro
E407 Hot water outlet temperature sensor fault Call a pro
E421 Cold water inlet temperature sensor 1 fault Call a pro
E432 Cold water inlet temperature sensor 2 fault Call a pro
E434 Water adjustment valve fault Call a pro
E439 Flow sensor fault Call a pro
E441 Hot water inlet temperature sensor 2 fault Call a pro
E445 Bypass mixing valve fault Call a pro
E515 Circuit board fault Safe checks first, then a pro
E517 DIP switch setting error Call a pro
E593 Front panel button fault Call a pro