Navien tankless water heater code E110: Abnormal air pressure (blocked vent or intake filter)
Tankless water heater, Canada and United States
The heater detected abnormal air pressure in its combustion air or exhaust path and stopped.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the flue or exhaust. A blocked or leaking flue can let carbon monoxide into the home.
What causes it
Canadian and US models
-
The intake air filter is clogged with dust or lint.
-
Something is blocking the exhaust vent pipe or its outside termination.
Check the outside flue or vent terminal is clearYou can do this
- Find where the flue or vent pipe ends outside the building. High-efficiency furnaces and some water heaters also have a combustion air intake pipe beside it: check that one too. On some outdoor water heaters the flue outlet is part of the front cover.
- Look for anything blocking it, such as leaves, a bird or insect nest, snow, plants, or items stored against the wall.
- Cut back plants and move stored items away from it. Do not touch, poke into or hose the flue outlet. If something is inside it, book a service. The terminal can be hot. Do not climb onto the roof or use a ladder to reach it; if it is out of reach, book a technician.
-
A venting or air pressure problem that a technician needs to find. Suspect this when the code comes back with the filter clean and the vent clear.
US models
-
Something is blocking the vent pipe or its outside termination.
Same check as above: Check the outside flue or vent terminal is clear
-
A venting or air pressure problem that a technician needs to find. Suspect this when the code comes back with the vent clear.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
21 models in 6 ranges
| Range | Models |
|---|---|
| NPE-A (first generation) | NPE-180A, NPE-210A, NPE-240A |
| NPE-S (first generation) | NPE-150S, NPE-180S, NPE-210S, NPE-240S |
| NPE-A2 | NPE-180A2, NPE-210A2, NPE-240A2 |
| NPE-S2 | NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2 |
| NPN-E | NPN-120E, NPN-160E, NPN-180E, NPN-199E |
| NPN-U | NPN-160U, NPN-180U, NPN-199U |
Where this comes from
- User's Information Manual, NPE-A/S condensing tankless water heaters (20026535G) , page 13, 16
- User's Information Manual, NPE-A2/S2 condensing tankless water heaters (20049624A) , page 14, 17
- User's Information Manual, NPN non-condensing tankless water heaters (20045995B) , page 22
Checked against the manufacturer's manual on 9 October 2026.
Other Navien tankless water heater codes
| Code | Meaning | What you can do |
|---|---|---|
| E031 | Burner overheated | Call a pro |
| E046 | Limit control fault | Call a pro |
| E047 | Exhaust temperature sensor fault | Call a pro |
| E056 | Modulating gas valve fault | Call a pro |
| E060 | Dual venturi fault | Call a pro |
| E109 | Fan motor fault | Safe checks first, then a pro |
| E127 | Air volume sensor fault | Call a pro |
| E157 | Air volume control fault | Call a pro |
| E170 | Freeze protection heater fault | Call a pro |
| E407 | Hot water outlet temperature sensor fault | Call a pro |
| E421 | Cold water inlet temperature sensor 1 fault | Call a pro |
| E762 | Vent pipe not fully inserted | Call a pro |