- Home
- Rinnai
- gas heaters
- Code 14
Rinnai gas heater code 14: Filter blocked or overheat
Gas heater, Australia
The fan filter is blocked or the heater has overheated, so it stopped.
You can often clear this yourself. Work through the causes below in order, most likely first.
What causes it
-
The fan filter at the back of the heater is clogged with dust or lint.
Clean the Energysaver fan filterYou can do this
- Turn the heater off and wait until the fan has stopped and the heater is cool, then unplug it. Do not unplug the heater while the fan is still running.
- Pull the fan filter straight up and out of the back of the heater. The 1005FT has two filters.
- Vacuum or dust a dry filter. If it is oily, wash it in mild detergent, drain it and let it dry fully.
- Refit the filter, plug the heater in and turn it on. Never run the heater without the filter in place, and do not keep using it with the filter indicator flashing.
- Clean the filter weekly during the heating season to stop this code returning.
- Turn the heater off and wait until the fan has stopped and the heater is cool, then unplug it.
-
If the code returns with a clean filter, the heater needs a service call.
How to read this code on your unit
Booking a licensed gasfitter
Book a licensed gasfitterlicensed gasfitter
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gasfitter and give them those details.
Models that show this code
6 models in 2 ranges
| Range | Models |
|---|---|
| Energysaver FDT commercial flued gas heater | RHFE-559FTSN (Energysaver 559FDT), RHFE-1005FTSN (Energysaver 1005FDT) |
| Energysaver FT flued gas heater | RHFE-309FT3 (Energysaver 309FT), RHFE-559FT3 (Energysaver 559FT), RHFE-561FT3 (Energysaver 561FT), RHFE-1005FT3 (Energysaver 1005FT) |
Where this comes from
- Error codes for Energysaver flued gas heaters (HE Gas Energysaver FT FDT ERR) , page 1
- Energysaver FT gas heater operation and installation manual , page 18, 21
Checked against the manufacturer's manual on 9 October 2026.
Other Rinnai gas heater codes
| Code | Meaning | What you can do |
|---|---|---|
| 11 | Ignition failure | Safe checks first, then a pro |
| 12 | Flame failure | Safe checks first, then a pro |
| 16 | Room overheat | You can often fix it |
| 30 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 31 | Room temperature sensor fault | Safe checks first, then a pro |
| 32 | Room temperature sensor fault | Safe checks first, then a pro |
| 33 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 34 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 35 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 40 | Sensor tube failure | Call a pro |
| 49 | Sensor breakdown | Safe checks first, then a pro |
| 53 | Spark sensor fault | Call a pro |