Rinnai gas heater code 16: Room overheat
Gas heater, Australia
The heater sensed a room temperature above 40°C.
You can often clear this yourself. Work through the causes below in order, most likely first.
What causes it
-
The room is warmer than 40°C.
Let the room cool below 40°CYou can do this
- Ventilate the room, or wait until it is below 40°C, then turn the heater on again.
- If the code shows when the room is not hot, book a service call.
How to read this code on your unit
Models that show this code
6 models in 2 ranges
| Range | Models |
|---|---|
| Energysaver FDT commercial flued gas heater | RHFE-559FTSN (Energysaver 559FDT), RHFE-1005FTSN (Energysaver 1005FDT) |
| Energysaver FT flued gas heater | RHFE-309FT3 (Energysaver 309FT), RHFE-559FT3 (Energysaver 559FT), RHFE-561FT3 (Energysaver 561FT), RHFE-1005FT3 (Energysaver 1005FT) |
Where this comes from
- Error codes for Energysaver flued gas heaters (HE Gas Energysaver FT FDT ERR) , page 1
- Energysaver FT gas heater operation and installation manual , page 21
Checked against the manufacturer's manual on 9 October 2026.
Other Rinnai gas heater codes
| Code | Meaning | What you can do |
|---|---|---|
| 11 | Ignition failure | Safe checks first, then a pro |
| 12 | Flame failure | Safe checks first, then a pro |
| 14 | Filter blocked or overheat | You can often fix it |
| 30 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 31 | Room temperature sensor fault | Safe checks first, then a pro |
| 32 | Room temperature sensor fault | Safe checks first, then a pro |
| 33 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 34 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 35 | Overheat temperature sensor fault | Safe checks first, then a pro |
| 40 | Sensor tube failure | Call a pro |
| 49 | Sensor breakdown | Safe checks first, then a pro |
| 53 | Spark sensor fault | Call a pro |