Carrier gas furnace code 23.2: Secondary pressure switch stuck closed

Gas furnace, Canada and United States

The secondary pressure switch is closed when it should be open, so the control will not start heating.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

This involves the flue or exhaust. A blocked or leaking flue can let carbon monoxide into the home.

Only some models show this code. Check the list below.

What causes it

  1. Blocked pressure tubing holding the switch closed.

    Book a licensed gas technician

  2. A pressure switch stuck closed.

    Book a licensed gas technician

How to read this code on your unit

The three-digit display sits on the furnace control behind the blower door. Through the sight glass in the door you see only the status light, which flashes the first two digits of the code. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is a 33.x code. Write down what you see before you open the door or switch the furnace off. The full code with its third digit shows on the control display only with the door removed and the door switch closed, which is a job for a technician. A technician can also look back at the last 7 faults in the FLt menu. Stored codes are erased by themselves after 72 hours of powered operation after the last fault, and the display shows non when no fault is stored.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

20 models in 2 ranges
RangeModels
59SC2E59SC2E040M14-12, 59SC2E040M17-12, 59SC2E060M14-12, 59SC2E060M17-14, 59SC2E080M17-16, 59SC2E080M21-20, 59SC2E100M21-20, 59SC2E100M21-22, 59SC2E120M24-20
59SC6A59SC6A026M14-10, 59SC6A040M14-10, 59SC6A040M17-12, 59SC6A060M14-12, 59SC6A060M17-16, 59SC6A080M17-16, 59SC6A080M21-20, 59SC6A100M21-20, 59SC6A100M21-22, 59SC6A120M24-22, 59SC6A140M24-22

Where this comes from

Checked against the manufacturer's manual on 27 October 2026.

Report a mistake on this page

Other Carrier gas furnace codes

Code Meaning What you can do
23 Flue or venting fault (depends on model) Call a pro
42 Inducer motor fault Safe checks first, then a pro
43 Lower pressure switch open while a higher one is closed Call a pro
14.4 Lockout after repeated pressure switch openings Safe checks first, then a pro
23.1 Flue or venting fault (depends on model) Call a pro
23.3 Pressure transducer senses over-pressure Call a pro
23.4 Low pressure switch stuck closed Call a pro
23.5 High pressure switch stuck closed Call a pro
23.6 Medium pressure switch stuck closed Call a pro
31.1 Flue or venting fault (depends on model) Depends on your model
31.2 Flue or venting fault (depends on model) Depends on your model
31.3 Secondary pressure switch lockout after 3 failed trials Safe checks first, then a pro