Carrier gas furnace error codes
Complete list of 93 checked codes for Carrier gas furnaces, with what each code means and whether you can fix it yourself.
Reference sheet from https://faultcodeindex.com/carrier/gas-furnace/ (checked against Carrier manuals).
| Code | Meaning | What you can do |
|---|---|---|
| 11 | No previous fault stored | You can often fix it |
| 13 | Limit circuit lockout (depends on model) | Safe checks first, then a pro |
| 14 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 15 | Blower motor lockout | Call a pro |
| 21 | Gas heating lockout, fault in the gas valve circuit | Safe checks first, then a pro |
| 22 | Flame sensed while the gas valve is off | Safe checks first, then a pro |
| 23 | Flue or venting fault (depends on model) | Call a pro |
| 24 | 24-volt fuse on the control has blown | Call a pro |
| 25 | Model plug missing or wrong, or a setup switch error | Call a pro |
| 26 | Burner thermal switch open | Call a pro |
| 31 | Flue or venting fault (depends on model) | Safe checks first, then a pro |
| 32 | Low or low-heat pressure switch did not close, or opened again | Safe checks first, then a pro |
| 33 | Limit circuit fault, a limit or rollout switch is open | Safe checks first, then a pro |
| 34 | Flame not proved during ignition | Safe checks first, then a pro |
| 35 | Modulating gas valve not communicating | Call a pro |
| 41 | Blower motor fault, speed or communication lost | Call a pro |
| 42 | Inducer motor fault | Safe checks first, then a pro |
| 43 | Lower pressure switch open while a higher one is closed | Call a pro |
| 45 | Control circuitry lockout | Call a pro |
| 10.1 | Line voltage polarity reversed | Call a pro |
| 10.2 | Refrigerant leak detected, dissipation active | Call a pro |
| 13.1 | Limit circuit lockout, a limit or rollout switch stayed open | Safe checks first, then a pro |
| 14.1 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 14.2 | Flame lost 3 times after 70 seconds of heating | Safe checks first, then a pro |
| 14.3 | Lockout after 7 flame losses in one heat request | Safe checks first, then a pro |
| 14.4 | Lockout after repeated pressure switch openings | Safe checks first, then a pro |
| 15.1 | Blower lockout, no blower speed signal | Call a pro |
| 15.2 | Blower lockout, blower never reached 500 rpm | Call a pro |
| 17.1 | Lost communication with the Bluetooth module | Call a pro |
| 19.1 | Lost InteliSense communication with the thermostat | Call a pro |
| 21.1 | 24 volts sensed at the gas valve when there should be none | Safe checks first, then a pro |
| 22.1 | Flame proved while the gas valve is off | Safe checks first, then a pro |
| 23.1 | Flue or venting fault (depends on model) | Call a pro |
| 23.2 | Secondary pressure switch stuck closed | Call a pro |
| 23.3 | Pressure transducer senses over-pressure | Call a pro |
| 23.4 | Low pressure switch stuck closed | Call a pro |
| 23.5 | High pressure switch stuck closed | Call a pro |
| 23.6 | Medium pressure switch stuck closed | Call a pro |
| 24.1 | Fuse fault, short in the 24-volt wiring | Call a pro |
| 25.1 | Control has no program loaded | Call a pro |
| 25.2 | Control program file is corrupted | Call a pro |
| 25.3 | Twinned furnaces are not identical | Call a pro |
| 25.4 | Main program invalid, running on the backup program | Call a pro |
| 25.5 | Installer settings are corrupted | Call a pro |
| 25.6 | Wrong program loaded for this control | Call a pro |
| 25.7 | Non-condensing program in a condensing furnace | Call a pro |
| 26.1 | Burner thermal switch open, permanent lockout | Call a pro |
| 26.2 | Burner thermal switch open, permanent lockout | Call a pro |
| 27.1 | Program in super plug is missing or corrupted | Call a pro |
| 27.2 | Program in super plug is missing or corrupted | Call a pro |
| 27.3 | Program in super plug is missing or corrupted | Call a pro |
| 31.1 | Flue or venting fault (depends on model) | Depends on your model |
| 31.2 | Flue or venting fault (depends on model) | Depends on your model |
| 31.3 | Secondary pressure switch lockout after 3 failed trials | Safe checks first, then a pro |
| 31.4 | Loss of pressure before the blower started | Safe checks first, then a pro |
| 31.5 | Loss of pressure after the blower started | Safe checks first, then a pro |
| 31.6 | High pressure switch open | Safe checks first, then a pro |
| 31.7 | High heat only, high switch failed to close in time | Safe checks first, then a pro |
| 32.1 | Main pressure switch (LPS) open | Safe checks first, then a pro |
| 32.2 | Low pressure switch open | Safe checks first, then a pro |
| 33.1 | Limit circuit switch open, blower running to cool the furnace | Safe checks first, then a pro |
| 33.2 | High heat only for the current cycle | Safe checks first, then a pro |
| 34.1 | Ignition fault, burners did not light in 4 trials | Safe checks first, then a pro |
| 34.2 | Flame lost before the heating blower started | Safe checks first, then a pro |
| 34.3 | Flame lost after the heating blower started | Safe checks first, then a pro |
| 34.4 | Flame lost at reduced inducer pressure or in Self Healing mode | Safe checks first, then a pro |
| 34.5 | Low heat flame lost before the blower started | Safe checks first, then a pro |
| 34.6 | Low heat flame lost after the blower started | Safe checks first, then a pro |
| 34.7 | High heat flame lost before the blower started | Safe checks first, then a pro |
| 34.8 | High heat flame lost after the blower started | Safe checks first, then a pro |
| 35.1 | Modulating gas valve not communicating | Call a pro |
| 41.1 | No blower speed at start-up | Call a pro |
| 41.2 | Blower speed lost while running | Call a pro |
| 41.3 | Blower not reaching 500 rpm | Call a pro |
| 42.1 | No inducer speed at start-up | Call a pro |
| 42.2 | Inducer speed lost while running | Call a pro |
| 42.3 | Inducer over its speed limit | Call a pro |
| 43.1 | High switch closed before the low switch | Call a pro |
| 45.1 | Internal control fault | Call a pro |
| 45.2 | Gas valve relay will not close | Call a pro |
| 45.3 | Control memory (EEPROM) fault | Call a pro |
| 45.4 | Microprocessor communication lost | Call a pro |
| 46.1 | Momentary loss of power | Call a pro |
| 51.1 | Outdoor air sensor open | Call a pro |
| 51.2 | Outdoor air sensor shorted | Call a pro |
| 52.1 | Supply air sensor open | Call a pro |
| 52.2 | Supply air sensor shorted | Call a pro |
| 53.1 | Return air sensor open | Call a pro |
| 53.2 | Return air sensor shorted | Call a pro |
| btL | Firmware failed to load | Call a pro |
| amber light off | No power to the furnace control | You can often fix it |
| amber light flashing rapidly | Line voltage polarity reversed or the furnace is not grounded | Call a pro |
| steady amber light | Normal, the control has power and no fault to show | You can often fix it |
Model ranges
- 58CTA/CTX
- 58CU0A
- 58CU0B
- 58CVA/CVX
- 58DLA/DLX
- 58SB0A/58SB1A
- 58SB0B/58SB1B
- 58SC0A/58SC1A
- 58SC0B/58SC1B
- 58SP0A/58SP1A
- 58SP0B/58SP1B
- 58STA/STX
- 58SU0A
- 58SU0B
- 58TN0A/58TN1A
- 58TN0B/58TN1B
- 58TP0A/58TP1A
- 58TP0B/58TP1B
- 59CU5A
- 59CU5B
- 59MN7A
- 59MN7B
- 59MN7C
- 59SC2A, 59SC2B and 59SC2C
- 59SC2D
- 59SC2E
- 59SC5A
- 59SC5B
- 59SC6A
- 59SP5A
- 59SP6A
- 59SU5A
- 59SU5B
- 59TN6A
- 59TN6B
- 59TN6C
- 59TN7A
- 59TP5A
- 59TP6A
- 59TP6B
- 59TP6C
- 59TP7A