Carrier gas furnace code 41: Blower motor fault, speed or communication lost

Gas furnace, Canada and United States

The blower did not reach 250 rpm, or did not communicate with the control in time, either within 30 seconds of being turned on or within 10 seconds while running. If this happens at start-up in two heating cycles in a row, the control locks out with code 15.

On the status light, this code is 4 short flashes, then 1 long flash.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

Only some models show this code. Check the list below.

What causes it

Standard amber-LED furnaces

  1. The blower wheel is loose or rubbing.

    Book a licensed gas technician

  2. A wiring fault between the furnace control and the blower motor.

    Book a licensed gas technician

  3. A failed blower control module or blower motor, or a failed furnace control.

    Book a licensed gas technician

Ultra-low NOx furnaces

  1. A fault in the blower motor or its wiring, or in the furnace control. The component test on the label points a technician at the blower, its wiring and the control.

    Book a licensed gas technician

How to read this code on your unit

The amber status light (red on some older boards) on the furnace control shows through a small window in the blower access door. A steady light means the control has power and no fault to show. A code is two digits. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is code 33, and 1 short then 1 long is code 11. Write the code down before you open the door or switch the furnace off.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

50 models in 7 ranges
RangeModels
58CVA/CVX58CVA070-12, 58CVA090-16, 58CVA110-20, 58CVA135-22, 58CVA155-22, 58CVX070-12, 58CVX090-16, 58CVX110-20, 58CVX135-22, 58CVX155-22
58TN0A/58TN1A58TN0A045C17-12, 58TN0A070C14-12, 58TN0A070C17-16, 58TN0A070C21-20, 58TN0A090C17-16, 58TN0A090C21-20, 58TN0A110C21-20, 58TN0A135C24-22, 58TN1A045C17-12, 58TN1A070C14-12, 58TN1A070C17-16, 58TN1A070C21-20, 58TN1A090C17-16, 58TN1A090C21-20, 58TN1A110C21-20, 58TN1A135C24-22
59MN7A59MN7A060V17-14, 59MN7A080V17-14, 59MN7A060V21-20, 59MN7A080V21-20, 59MN7A100V21-22, 59MN7A120V24-22
59MN7B59MN7B060C17-14, 59MN7B060C21-20, 59MN7B080C17-14, 59MN7B080C21-20, 59MN7B100C21-22, 59MN7B120C24-22
59TN6B59TN6B060C17-14, 59TN6B080C17-14, 59TN6B080C21-20, 59TN6B100C21-22, 59TN6B120C24-22
58CU0A58CU0A040C17-12, 58CU0A060C17-16, 58CU0A080C21-20, 58CU0A100C21-20
59CU5A59CU5A060C17-16, 59CU5A080C21-20, 59CU5A100C21-22

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Carrier gas furnace codes

Code Meaning What you can do
15 Blower motor lockout Call a pro
33 Limit circuit fault, a limit or rollout switch is open Safe checks first, then a pro
34 Flame not proved during ignition Safe checks first, then a pro
35 Modulating gas valve not communicating Call a pro
42 Inducer motor fault Safe checks first, then a pro
43 Lower pressure switch open while a higher one is closed Call a pro
45 Control circuitry lockout Call a pro
15.1 Blower lockout, no blower speed signal Call a pro
15.2 Blower lockout, blower never reached 500 rpm Call a pro
41.1 No blower speed at start-up Call a pro
41.2 Blower speed lost while running Call a pro
41.3 Blower not reaching 500 rpm Call a pro