Carrier gas furnace code 33: Limit circuit fault, a limit or rollout switch is open
Gas furnace, Canada and United States
A limit or flame rollout switch is open. On 80% furnaces the draft safeguard and blocked vent switch (where fitted) are in the same circuit. The blower runs for at least 4 minutes, and if the switch stays open for more than 3 minutes the code changes to 13. On later two-stage boards and the modulating boards, 33 also shows when the furnace is held at high heat after 2 limit trips in a row at a lower rate. The rollout switch and the blocked vent switch must be reset by hand.
On the status light, this code is 3 short flashes, then 3 long flashes.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the flue or exhaust. A blocked or leaking flue can let carbon monoxide into the home.
What causes it
-
Not enough air moving through the furnace because of a dirty filter or a restricted duct system, including closed or blocked registers and grilles.
Check and clean or replace the furnace filterYou can do this
- Turn off the electrical supply to the furnace.
- Open the filter cabinet door on the side or bottom of the furnace and slide the filter out, dirty side up so the dirt does not spill. If your filter is fitted somewhere else, ask your dealer how to reach it.
- If the filter is torn, replace it. A dirty disposable media filter is not cleaned; replace it with one of the same part number and size, with its airflow arrow pointing towards the blower.
- Wash a dirty washable filter in cold water, spraying it from the opposite side to the airflow. A mild liquid detergent is fine. Let it dry.
- Put the clean filter back, close the filter door and turn the power back on. Never run the furnace without a filter in place. Check the filter every four weeks and always use the size and type originally specified for your furnace.
Check the supply registers and return-air grilles are openYou can do this
- Go round the house and check the supply registers, where warm air comes out, are open.
- Check the return-air grilles are open and not covered by furniture, rugs or stored items.
- Check the furnace filter as well. If the airflow is still poor, call your dealer for service.
-
A flame rollout switch has tripped, which the labels link to an inadequate combustion air supply. It stays open until it is reset by hand.
Reset the furnace's rollout switch onceYou can do this
- Write down the status light code before you turn anything off.
- Turn off the electrical supply to the furnace, then remove the main furnace door.
- Find the manual reset rollout switch on the burner box and press its button once to reset it.
- Refit the door and turn the power back on.
- If the switch trips again, shut the furnace down and call for service. Reset it once only. The switch trips when the furnace overheats around the burners, which points to a combustion air, gas pressure, burner or venting problem that a technician must find and correct. Never bypass or jumper the switch.
-
A restricted or wrongly sized vent, or strong wind at the vent. On 80% furnaces this can open the draft safeguard or blocked vent switch.
Check the vent and air intake pipes outside are clearYou can do this
- Find where the furnace vent pipe ends outside the house. A two-pipe (direct-vent) installation also has an air intake pipe ending outside. Check only what you can see from the ground. Do not climb onto the roof or use a ladder. If the vent ends on the roof or goes into a chimney, book a technician to check it.
- Check nothing is blocking or covering the ends of the pipes, in any season, and clear anything stored or growing around them.
- On a condensing furnace with a one-pipe installation, also check the combustion-air pipe next to the furnace is not blocked and nothing is crowding the air openings around the furnace.
- If a pipe is blocked inside, has holes or has come apart, do not run the furnace. Call your dealer. A blocked, holed or disconnected vent pipe can let toxic fumes into your home.
- Find where the furnace vent pipe ends outside the house. A two-pipe (direct-vent) installation also has an air intake pipe ending outside.
-
A loose blower wheel, or a faulty blower motor or capacitor.
-
A faulty limit switch or connection, a wrong limit switch or missing limit gasket, the gas input set wrongly, or on two-stage boards a stuck high-heat solenoid in the gas valve.
How to read this code on your unit
The amber status light (red on some older boards) on the furnace control shows through a small window in the blower access door. A steady light means the control has power and no fault to show. A code is two digits. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is code 33, and 1 short then 1 long is code 11. Write the code down before you open the door or switch the furnace off.
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
312 models in 22 ranges
| Range | Models |
|---|---|
| 58CTA/CTX | 58CTA045-08, 58CTA045-12, 58CTA070-08, 58CTA070-12, 58CTA070-16, 58CTA090-14, 58CTA090-16, 58CTA090-20, 58CTA110-12, 58CTA110-16, 58CTA110-22, 58CTA135-16, 58CTA135-22, 58CTA155-20, 58CTX045-08, 58CTX045-12, 58CTX070-08, 58CTX070-12, 58CTX070-16, 58CTX090-14, 58CTX090-16, 58CTX090-20, 58CTX110-12, 58CTX110-16, 58CTX110-22, 58CTX135-16, 58CTX135-22, 58CTX155-20 |
| 58CVA/CVX | 58CVA070-12, 58CVA090-16, 58CVA110-20, 58CVA135-22, 58CVA155-22, 58CVX070-12, 58CVX090-16, 58CVX110-20, 58CVX135-22, 58CVX155-22 |
| 58DLA/DLX | 58DLA045-08, 58DLA045-12, 58DLA070-08, 58DLA070-12, 58DLA070-16, 58DLA090-14, 58DLA090-16, 58DLA090-20, 58DLA110-12, 58DLA110-16, 58DLA110-22, 58DLA135-16, 58DLA135-22, 58DLA155-20, 58DLX045-08, 58DLX045-12, 58DLX070-08, 58DLX070-12, 58DLX070-16, 58DLX090-14, 58DLX090-16, 58DLX090-20, 58DLX110-12, 58DLX110-16, 58DLX110-22, 58DLX135-16, 58DLX135-22, 58DLX155-20 |
| 58SB0A/58SB1A | 58SB0A045E14-12, 58SB0A045E17-12, 58SB0A070E14-12, 58SB0A070E17-12, 58SB0A070E17-16, 58SB0A070E21-16, 58SB0A090E17-14, 58SB0A090E21-16, 58SB0A090E21-20, 58SB0A090E24-20, 58SB0A110E21-20, 58SB0A110E24-20, 58SB0A135E24-20, 58SB0A155E24-20, 58SB1A045E14-12, 58SB1A045E17-12, 58SB1A070E14-12, 58SB1A070E17-12, 58SB1A070E17-16, 58SB1A070E21-16, 58SB1A090E17-14, 58SB1A090E21-16, 58SB1A090E21-20, 58SB1A090E24-20, 58SB1A110E21-20, 58SB1A110E24-20, 58SB1A135E24-20, 58SB1A155E24-20 |
| 58SC0A/58SC1A | 58SC0A045E14-12, 58SC0A045E17-12, 58SC0A070E14-12, 58SC0A070E17-12, 58SC0A070E17-16, 58SC0A070E21-16, 58SC0A090E17-14, 58SC0A090E21-16, 58SC0A090E21-20, 58SC0A090E24-20, 58SC0A110E21-20, 58SC0A110E24-20, 58SC0A135E24-20, 58SC1A045E14-12, 58SC1A045E17-12, 58SC1A070E14-12, 58SC1A070E17-12, 58SC1A070E17-16, 58SC1A070E21-16, 58SC1A090E17-14, 58SC1A090E21-16, 58SC1A090E21-20, 58SC1A090E24-20, 58SC1A110E21-20, 58SC1A110E24-20, 58SC1A135E24-20 |
| 58SP0A/58SP1A | 58SP0A045V14-12, 58SP0A045V17-16, 58SP0A070V17-16, 58SP0A070V21-20, 58SP0A090V21-20, 58SP0A090V24-20, 58SP0A110V24-22, 58SP1A045V14-12, 58SP1A045V17-16, 58SP1A070V17-16, 58SP1A070V21-20, 58SP1A090V21-20, 58SP1A090V24-20, 58SP1A110V24-22 |
| 58STA/STX | 58STA045-08, 58STA045-12, 58STA070-08, 58STA070-12, 58STA070-16, 58STA090-14, 58STA090-16, 58STA090-20, 58STA110-12, 58STA110-16, 58STA110-22, 58STA135-16, 58STA135-22, 58STA155-20, 58STX045-08, 58STX045-12, 58STX070-08, 58STX070-12, 58STX070-16, 58STX090-14, 58STX090-16, 58STX090-20, 58STX110-12, 58STX110-16, 58STX110-22, 58STX135-16, 58STX135-22, 58STX155-20 |
| 58TN0A/58TN1A | 58TN0A045C17-12, 58TN0A070C14-12, 58TN0A070C17-16, 58TN0A070C21-20, 58TN0A090C17-16, 58TN0A090C21-20, 58TN0A110C21-20, 58TN0A135C24-22, 58TN1A045C17-12, 58TN1A070C14-12, 58TN1A070C17-16, 58TN1A070C21-20, 58TN1A090C17-16, 58TN1A090C21-20, 58TN1A110C21-20, 58TN1A135C24-22 |
| 58TP0A/58TP1A | 58TP0A045V14-12, 58TP0A070V14-12, 58TP0A070V17-16, 58TP0A090V17-16, 58TP0A090V21-20, 58TP0A110V21-22, 58TP0A135V24-22, 58TP1A045V14-12, 58TP1A070V14-12, 58TP1A070V17-16, 58TP1A090V17-16, 58TP1A090V21-20, 58TP1A110V21-22, 58TP1A135V24-22 |
| 59MN7A | 59MN7A060V17-14, 59MN7A080V17-14, 59MN7A060V21-20, 59MN7A080V21-20, 59MN7A100V21-22, 59MN7A120V24-22 |
| 59MN7B | 59MN7B060C17-14, 59MN7B060C21-20, 59MN7B080C17-14, 59MN7B080C21-20, 59MN7B100C21-22, 59MN7B120C24-22 |
| 59SC2A, 59SC2B and 59SC2C | 59SC2A040E14-10, 59SC2A060E14-10, 59SC2A060E17-14, 59SC2A080E17-16, 59SC2A080E21-20, 59SC2A100E21-14, 59SC2A100E21-20, 59SC2A120E24-20, 59SC2B040E14-10, 59SC2B060E14-12, 59SC2B040E17-12, 59SC2B060E17-16, 59SC2B080E17-16, 59SC2B080E21-20, 59SC2B100E21-16, 59SC2B100E21-22, 59SC2B120E24-22, 59SC2C040E14-10, 59SC2C060E14-12, 59SC2C040E17-12, 59SC2C060E17-16, 59SC2C080E17-16, 59SC2C080E21-20, 59SC2C100E21-16, 59SC2C100E21-20, 59SC2C120E24-20 |
| 59SC2D | 59SC2D040E14-10, 59SC2D040E17-12, 59SC2D060E14-12, 59SC2D060E17-14, 59SC2D080E17-16, 59SC2D080E21-20, 59SC2D100E21-20, 59SC2D100E21-22, 59SC2D120E24-20 |
| 59SC5A | 59SC5A026E14-08, 59SC5A040E14-10, 59SC5A060E14-10, 59SC5A040E17-12, 59SC5A060E17-14, 59SC5A080E17-16, 59SC5A080E21-20, 59SC5A100E21-14, 59SC5A100E21-20, 59SC5A120E24-20, 59SC5A140E24-20 |
| 59SC5B | 59SC5B026E14-10, 59SC5B040E14-10, 59SC5B040E17-12, 59SC5B060E14-12, 59SC5B060E17-16, 59SC5B080E17-16, 59SC5B080E21-20, 59SC5B100E21-20, 59SC5B100E21-22, 59SC5B120E24-22, 59SC5B140E24-22 |
| 59SP5A | 59SP5A026E14-10, 59SP5A040E14-10, 59SP5A060E14-12, 59SP5A040E17-12, 59SP5A060E17-14, 59SP5A080E17-16, 59SP5A080E21-20, 59SP5A100E21-20, 59SP5A120E24-22 |
| 59SP6A | 59SP6A040V14-10, 59SP6A040V17-12, 59SP6A060V14-12, 59SP6A060V17-14, 59SP6A080V17-16, 59SP6A080V21-20, 59SP6A100V21-20, 59SP6A120V24-22 |
| 59TN6A | 59TN6A060V17-14, 59TN6A080V17-14, 59TN6A080V21-20, 59TN6A100V21-22, 59TN6A120V24-22 |
| 59TN6B | 59TN6B060C17-14, 59TN6B080C17-14, 59TN6B080C21-20, 59TN6B100C21-22, 59TN6B120C24-22 |
| 59TP5A | 59TP5A040E14-10, 59TP5A060E14-12, 59TP5A040E17-12, 59TP5A060E17-14, 59TP5A080E17-16, 59TP5A080E21-20, 59TP5A100E21-20, 59TP5A120E24-22 |
| 59TP6A | 59TP6A040V14-10, 59TP6A040V14-12, 59TP6A060V17-12, 59TP6A060V17-14, 59TP6A080V17-16, 59TP6A080V21-20, 59TP6A100V21-20, 59TP6A120V24-22 |
| 59TP6B | 59TP6B040V14-10, 59TP6B040V17-12, 59TP6B060V14-12, 59TP6B060V17-14, 59TP6B080V17-16, 59TP6B080V21-20, 59TP6B100V21-20, 59TP6B120V24-22 |
Where this comes from
- 59SC5A single-stage condensing gas furnace, installation, start-up, operating and service instructions (59SC5A-13SI) , page 67, 83
- 58STA/STX single-stage induced-combustion gas furnace, installation, start-up, operating and service instructions (58ST-24SI) , page 43, 50
- 59TP6A two-stage variable-speed condensing gas furnace, installation, start-up, operating and service instructions (59TP6A-10SI) , page 73, 90
- 59MN7A modulating condensing gas furnace, installation, start-up, operating and service instructions (59MN7A-12SI) , page 72
Checked against the manufacturer's manual on 11 October 2026.
Other Carrier gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| 13 | Limit circuit lockout (depends on model) | Safe checks first, then a pro |
| 26 | Burner thermal switch open | Call a pro |
| 31 | Flue or venting fault (depends on model) | Safe checks first, then a pro |
| 32 | Low or low-heat pressure switch did not close, or opened again | Safe checks first, then a pro |
| 34 | Flame not proved during ignition | Safe checks first, then a pro |
| 35 | Modulating gas valve not communicating | Call a pro |
| 41 | Blower motor fault, speed or communication lost | Call a pro |
| 13.1 | Limit circuit lockout, a limit or rollout switch stayed open | Safe checks first, then a pro |
| 26.1 | Burner thermal switch open, permanent lockout | Call a pro |
| 26.2 | Burner thermal switch open, permanent lockout | Call a pro |
| 33.1 | Limit circuit switch open, blower running to cool the furnace | Safe checks first, then a pro |
| 33.2 | High heat only for the current cycle | Safe checks first, then a pro |
See all overheat codes on gas furnaces across brands.