- Home
- Carrier
- gas furnaces
- 59SC2A, 59SC2B and 59SC2C
Carrier 59SC2A, 59SC2B and 59SC2C error codes
Every checked code for the Carrier 59SC2A, 59SC2B and 59SC2C range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| 11 | No previous fault stored | You can often fix it |
| 13 | Limit circuit lockout (depends on model) | Safe checks first, then a pro |
| 14 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 21 | Gas heating lockout, fault in the gas valve circuit | Safe checks first, then a pro |
| 22 | Flame sensed while the gas valve is off | Safe checks first, then a pro |
| 23 | Flue or venting fault (depends on model) | Call a pro |
| 24 | 24-volt fuse on the control has blown | Call a pro |
| 31 | Flue or venting fault (depends on model) | Safe checks first, then a pro |
| 33 | Limit circuit fault, a limit or rollout switch is open | Safe checks first, then a pro |
| 34 | Flame not proved during ignition | Safe checks first, then a pro |
| 45 | Control circuitry lockout | Call a pro |
| amber light off | No power to the furnace control | You can often fix it |
| amber light flashing rapidly | Line voltage polarity reversed or the furnace is not grounded | Call a pro |
| steady amber light | Normal, the control has power and no fault to show | You can often fix it |
Models in this range
- 59SC2A040E14-10
- 59SC2A060E14-10
- 59SC2A060E17-14
- 59SC2A080E17-16
- 59SC2A080E21-20
- 59SC2A100E21-14
- 59SC2A100E21-20
- 59SC2A120E24-20
- 59SC2B040E14-10
- 59SC2B060E14-12
- 59SC2B040E17-12
- 59SC2B060E17-16
- 59SC2B080E17-16
- 59SC2B080E21-20
- 59SC2B100E21-16
- 59SC2B100E21-22
- 59SC2B120E24-22
- 59SC2C040E14-10
- 59SC2C060E14-12
- 59SC2C040E17-12
- 59SC2C060E17-16
- 59SC2C080E17-16
- 59SC2C080E21-20
- 59SC2C100E21-16
- 59SC2C100E21-20
- 59SC2C120E24-20