- Home
- Carrier
- gas furnaces
- Code 14
Carrier gas furnace code 14: Ignition lockout after repeated failed lighting attempts
Gas furnace, Canada and United States
The furnace tried 4 times to light the burners and prove the flame, without success, so the control locked out. It retries by itself after 3 hours. The causes are the same as for code 34.
On the status light, this code is 1 short flash, then 4 long flashes.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
Standard amber-LED furnaces
-
The gas is off, with the manual shut-off valve to the furnace closed or the control switch on the gas valve turned off.
Check the gas is turned on to the furnaceYou can do this
- Check the manual shut-off valve in the gas pipe leading to the furnace is open.
- If the control switch on the furnace's gas valve may be off, use the start-up steps in the owner's manual or on the inside of the main furnace door. Set the thermostat to its lowest setting and OFF, close the manual gas valve, turn off the power and remove the main furnace door.
- Turn the control switch on the gas valve to OFF and wait five minutes, then smell for gas, including near the floor. If you smell gas, stop. Do not light any appliance or touch electrical switches. Leave the building and call your gas supplier from a neighbor's phone.
- If there is no gas smell, turn the control switch to ON, refit the main door, turn the power on and wait one minute, open the manual gas valve, then set the thermostat to HEAT above the room temperature.
- If the burners do not light, or the furnace locks out, shut the furnace down and call your dealer.
-
A dirty flame sensor (oxide build-up) or a flame sensing current that is too low.
-
Low inlet gas pressure, poor flame carryover or rough ignition, or a faulty hot surface igniter.
-
A grounding problem, such as the green/yellow wire not connected to the furnace sheet metal, poor control ground continuity, or a grounded flame sensor.
-
A faulty gas valve that does not open when it is powered.
Ultra-low NOx furnaces
-
The gas is off, with the manual shut-off valve to the furnace closed or the control switch on the gas valve turned off.
Same check as above: Check the gas is turned on to the furnace
-
A dirty flame sensor (oxide build-up) or a flame sensing current that is too low.
-
Low inlet gas pressure, poor flame carryover or rough ignition, or a faulty gas valve.
-
A grounding problem, such as the green/yellow wire not connected to the furnace sheet metal, poor control ground continuity, or a flame sensor that is grounded or touching the casing.
How to read this code on your unit
The amber status light (red on some older boards) on the furnace control shows through a small window in the blower access door. A steady light means the control has power and no fault to show. A code is two digits. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is code 33, and 1 short then 1 long is code 11. Write the code down before you open the door or switch the furnace off.
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
328 models in 26 ranges
| Range | Models |
|---|---|
| 58CTA/CTX | 58CTA045-08, 58CTA045-12, 58CTA070-08, 58CTA070-12, 58CTA070-16, 58CTA090-14, 58CTA090-16, 58CTA090-20, 58CTA110-12, 58CTA110-16, 58CTA110-22, 58CTA135-16, 58CTA135-22, 58CTA155-20, 58CTX045-08, 58CTX045-12, 58CTX070-08, 58CTX070-12, 58CTX070-16, 58CTX090-14, 58CTX090-16, 58CTX090-20, 58CTX110-12, 58CTX110-16, 58CTX110-22, 58CTX135-16, 58CTX135-22, 58CTX155-20 |
| 58CVA/CVX | 58CVA070-12, 58CVA090-16, 58CVA110-20, 58CVA135-22, 58CVA155-22, 58CVX070-12, 58CVX090-16, 58CVX110-20, 58CVX135-22, 58CVX155-22 |
| 58DLA/DLX | 58DLA045-08, 58DLA045-12, 58DLA070-08, 58DLA070-12, 58DLA070-16, 58DLA090-14, 58DLA090-16, 58DLA090-20, 58DLA110-12, 58DLA110-16, 58DLA110-22, 58DLA135-16, 58DLA135-22, 58DLA155-20, 58DLX045-08, 58DLX045-12, 58DLX070-08, 58DLX070-12, 58DLX070-16, 58DLX090-14, 58DLX090-16, 58DLX090-20, 58DLX110-12, 58DLX110-16, 58DLX110-22, 58DLX135-16, 58DLX135-22, 58DLX155-20 |
| 58SB0A/58SB1A | 58SB0A045E14-12, 58SB0A045E17-12, 58SB0A070E14-12, 58SB0A070E17-12, 58SB0A070E17-16, 58SB0A070E21-16, 58SB0A090E17-14, 58SB0A090E21-16, 58SB0A090E21-20, 58SB0A090E24-20, 58SB0A110E21-20, 58SB0A110E24-20, 58SB0A135E24-20, 58SB0A155E24-20, 58SB1A045E14-12, 58SB1A045E17-12, 58SB1A070E14-12, 58SB1A070E17-12, 58SB1A070E17-16, 58SB1A070E21-16, 58SB1A090E17-14, 58SB1A090E21-16, 58SB1A090E21-20, 58SB1A090E24-20, 58SB1A110E21-20, 58SB1A110E24-20, 58SB1A135E24-20, 58SB1A155E24-20 |
| 58SC0A/58SC1A | 58SC0A045E14-12, 58SC0A045E17-12, 58SC0A070E14-12, 58SC0A070E17-12, 58SC0A070E17-16, 58SC0A070E21-16, 58SC0A090E17-14, 58SC0A090E21-16, 58SC0A090E21-20, 58SC0A090E24-20, 58SC0A110E21-20, 58SC0A110E24-20, 58SC0A135E24-20, 58SC1A045E14-12, 58SC1A045E17-12, 58SC1A070E14-12, 58SC1A070E17-12, 58SC1A070E17-16, 58SC1A070E21-16, 58SC1A090E17-14, 58SC1A090E21-16, 58SC1A090E21-20, 58SC1A090E24-20, 58SC1A110E21-20, 58SC1A110E24-20, 58SC1A135E24-20 |
| 58SP0A/58SP1A | 58SP0A045V14-12, 58SP0A045V17-16, 58SP0A070V17-16, 58SP0A070V21-20, 58SP0A090V21-20, 58SP0A090V24-20, 58SP0A110V24-22, 58SP1A045V14-12, 58SP1A045V17-16, 58SP1A070V17-16, 58SP1A070V21-20, 58SP1A090V21-20, 58SP1A090V24-20, 58SP1A110V24-22 |
| 58STA/STX | 58STA045-08, 58STA045-12, 58STA070-08, 58STA070-12, 58STA070-16, 58STA090-14, 58STA090-16, 58STA090-20, 58STA110-12, 58STA110-16, 58STA110-22, 58STA135-16, 58STA135-22, 58STA155-20, 58STX045-08, 58STX045-12, 58STX070-08, 58STX070-12, 58STX070-16, 58STX090-14, 58STX090-16, 58STX090-20, 58STX110-12, 58STX110-16, 58STX110-22, 58STX135-16, 58STX135-22, 58STX155-20 |
| 58TN0A/58TN1A | 58TN0A045C17-12, 58TN0A070C14-12, 58TN0A070C17-16, 58TN0A070C21-20, 58TN0A090C17-16, 58TN0A090C21-20, 58TN0A110C21-20, 58TN0A135C24-22, 58TN1A045C17-12, 58TN1A070C14-12, 58TN1A070C17-16, 58TN1A070C21-20, 58TN1A090C17-16, 58TN1A090C21-20, 58TN1A110C21-20, 58TN1A135C24-22 |
| 58TP0A/58TP1A | 58TP0A045V14-12, 58TP0A070V14-12, 58TP0A070V17-16, 58TP0A090V17-16, 58TP0A090V21-20, 58TP0A110V21-22, 58TP0A135V24-22, 58TP1A045V14-12, 58TP1A070V14-12, 58TP1A070V17-16, 58TP1A090V17-16, 58TP1A090V21-20, 58TP1A110V21-22, 58TP1A135V24-22 |
| 59MN7A | 59MN7A060V17-14, 59MN7A080V17-14, 59MN7A060V21-20, 59MN7A080V21-20, 59MN7A100V21-22, 59MN7A120V24-22 |
| 59MN7B | 59MN7B060C17-14, 59MN7B060C21-20, 59MN7B080C17-14, 59MN7B080C21-20, 59MN7B100C21-22, 59MN7B120C24-22 |
| 59SC2A, 59SC2B and 59SC2C | 59SC2A040E14-10, 59SC2A060E14-10, 59SC2A060E17-14, 59SC2A080E17-16, 59SC2A080E21-20, 59SC2A100E21-14, 59SC2A100E21-20, 59SC2A120E24-20, 59SC2B040E14-10, 59SC2B060E14-12, 59SC2B040E17-12, 59SC2B060E17-16, 59SC2B080E17-16, 59SC2B080E21-20, 59SC2B100E21-16, 59SC2B100E21-22, 59SC2B120E24-22, 59SC2C040E14-10, 59SC2C060E14-12, 59SC2C040E17-12, 59SC2C060E17-16, 59SC2C080E17-16, 59SC2C080E21-20, 59SC2C100E21-16, 59SC2C100E21-20, 59SC2C120E24-20 |
| 59SC2D | 59SC2D040E14-10, 59SC2D040E17-12, 59SC2D060E14-12, 59SC2D060E17-14, 59SC2D080E17-16, 59SC2D080E21-20, 59SC2D100E21-20, 59SC2D100E21-22, 59SC2D120E24-20 |
| 59SC5A | 59SC5A026E14-08, 59SC5A040E14-10, 59SC5A060E14-10, 59SC5A040E17-12, 59SC5A060E17-14, 59SC5A080E17-16, 59SC5A080E21-20, 59SC5A100E21-14, 59SC5A100E21-20, 59SC5A120E24-20, 59SC5A140E24-20 |
| 59SC5B | 59SC5B026E14-10, 59SC5B040E14-10, 59SC5B040E17-12, 59SC5B060E14-12, 59SC5B060E17-16, 59SC5B080E17-16, 59SC5B080E21-20, 59SC5B100E21-20, 59SC5B100E21-22, 59SC5B120E24-22, 59SC5B140E24-22 |
| 59SP5A | 59SP5A026E14-10, 59SP5A040E14-10, 59SP5A060E14-12, 59SP5A040E17-12, 59SP5A060E17-14, 59SP5A080E17-16, 59SP5A080E21-20, 59SP5A100E21-20, 59SP5A120E24-22 |
| 59SP6A | 59SP6A040V14-10, 59SP6A040V17-12, 59SP6A060V14-12, 59SP6A060V17-14, 59SP6A080V17-16, 59SP6A080V21-20, 59SP6A100V21-20, 59SP6A120V24-22 |
| 59TN6A | 59TN6A060V17-14, 59TN6A080V17-14, 59TN6A080V21-20, 59TN6A100V21-22, 59TN6A120V24-22 |
| 59TN6B | 59TN6B060C17-14, 59TN6B080C17-14, 59TN6B080C21-20, 59TN6B100C21-22, 59TN6B120C24-22 |
| 59TP5A | 59TP5A040E14-10, 59TP5A060E14-12, 59TP5A040E17-12, 59TP5A060E17-14, 59TP5A080E17-16, 59TP5A080E21-20, 59TP5A100E21-20, 59TP5A120E24-22 |
| 59TP6A | 59TP6A040V14-10, 59TP6A040V14-12, 59TP6A060V17-12, 59TP6A060V17-14, 59TP6A080V17-16, 59TP6A080V21-20, 59TP6A100V21-20, 59TP6A120V24-22 |
| 59TP6B | 59TP6B040V14-10, 59TP6B040V17-12, 59TP6B060V14-12, 59TP6B060V17-14, 59TP6B080V17-16, 59TP6B080V21-20, 59TP6B100V21-20, 59TP6B120V24-22 |
| 58CU0A | 58CU0A040C17-12, 58CU0A060C17-16, 58CU0A080C21-20, 58CU0A100C21-20 |
| 58SU0A | 58SU0A040E17-12, 58SU0A060E17-16, 58SU0A080E21-20, 58SU0A100E21-20 |
| 59CU5A | 59CU5A060C17-16, 59CU5A080C21-20, 59CU5A100C21-22 |
| 59SU5A | 59SU5A040E17-12, 59SU5A060E17-16, 59SU5A080E21-20, 59SU5A100E21-20, 59SU5A100E21-22 |
Where this comes from
- 59SC5A single-stage condensing gas furnace, installation, start-up, operating and service instructions (59SC5A-13SI) , page 67, 83
- 59TP6A two-stage variable-speed condensing gas furnace, installation, start-up, operating and service instructions (59TP6A-10SI) , page 73, 89
- 58SU0A 80% single-stage ultra-low NOx gas furnace, installation, start-up, operating and service instructions (58SU0A-06SI) , page 33
- 59SU5A single-stage ultra-low NOx condensing gas furnace, installation, start-up, operating and service instructions (59SU5A-05SI) , page 51
- 59CU5A single-stage communicating ultra-low NOx condensing gas furnace, installation, start-up, operating and service instructions (59CU5A-01SI) , page 65
Checked against the manufacturer's manual on 9 October 2026.
Other Carrier gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| 11 | No previous fault stored | You can often fix it |
| 13 | Limit circuit lockout (depends on model) | Safe checks first, then a pro |
| 15 | Blower motor lockout | Call a pro |
| 21 | Gas heating lockout, fault in the gas valve circuit | Safe checks first, then a pro |
| 22 | Flame sensed while the gas valve is off | Safe checks first, then a pro |
| 23 | Flue or venting fault (depends on model) | Call a pro |
| 34 | Flame not proved during ignition | Safe checks first, then a pro |
| 14.1 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 14.2 | Flame lost 3 times after 70 seconds of heating | Safe checks first, then a pro |
| 14.3 | Lockout after 7 flame losses in one heat request | Safe checks first, then a pro |
| 14.4 | Lockout after repeated pressure switch openings | Safe checks first, then a pro |
| 34.1 | Ignition fault, burners did not light in 4 trials | Safe checks first, then a pro |
See all ignition failure codes on gas furnaces across brands.