- Home
- Carrier
- gas furnaces
- 58SC0A/58SC1A
Carrier 58SC0A/58SC1A error codes
Every checked code for the Carrier 58SC0A/58SC1A range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| 11 | No previous fault stored | You can often fix it |
| 13 | Limit circuit lockout (depends on model) | Safe checks first, then a pro |
| 14 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 21 | Gas heating lockout, fault in the gas valve circuit | Safe checks first, then a pro |
| 22 | Flame sensed while the gas valve is off | Safe checks first, then a pro |
| 23 | Flue or venting fault (depends on model) | Call a pro |
| 24 | 24-volt fuse on the control has blown | Call a pro |
| 31 | Flue or venting fault (depends on model) | Safe checks first, then a pro |
| 33 | Limit circuit fault, a limit or rollout switch is open | Safe checks first, then a pro |
| 34 | Flame not proved during ignition | Safe checks first, then a pro |
| 45 | Control circuitry lockout | Call a pro |
| amber light off | No power to the furnace control | You can often fix it |
| amber light flashing rapidly | Line voltage polarity reversed or the furnace is not grounded | Call a pro |
| steady amber light | Normal, the control has power and no fault to show | You can often fix it |
Models in this range
- 58SC0A045E14-12
- 58SC0A045E17-12
- 58SC0A070E14-12
- 58SC0A070E17-12
- 58SC0A070E17-16
- 58SC0A070E21-16
- 58SC0A090E17-14
- 58SC0A090E21-16
- 58SC0A090E21-20
- 58SC0A090E24-20
- 58SC0A110E21-20
- 58SC0A110E24-20
- 58SC0A135E24-20
- 58SC1A045E14-12
- 58SC1A045E17-12
- 58SC1A070E14-12
- 58SC1A070E17-12
- 58SC1A070E17-16
- 58SC1A070E21-16
- 58SC1A090E17-14
- 58SC1A090E21-16
- 58SC1A090E21-20
- 58SC1A090E24-20
- 58SC1A110E21-20
- 58SC1A110E24-20
- 58SC1A135E24-20