- Home
- Carrier
- gas furnaces
- 58CTA/CTX
Carrier 58CTA/CTX error codes
Every checked code for the Carrier 58CTA/CTX range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| 11 | No previous fault stored | You can often fix it |
| 13 | Limit circuit lockout (depends on model) | Safe checks first, then a pro |
| 14 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 21 | Gas heating lockout, fault in the gas valve circuit | Safe checks first, then a pro |
| 22 | Flame sensed while the gas valve is off | Safe checks first, then a pro |
| 23 | Flue or venting fault (depends on model) | Call a pro |
| 24 | 24-volt fuse on the control has blown | Call a pro |
| 31 | Flue or venting fault (depends on model) | Safe checks first, then a pro |
| 32 | Low or low-heat pressure switch did not close, or opened again | Safe checks first, then a pro |
| 33 | Limit circuit fault, a limit or rollout switch is open | Safe checks first, then a pro |
| 34 | Flame not proved during ignition | Safe checks first, then a pro |
| 43 | Lower pressure switch open while a higher one is closed | Call a pro |
| 45 | Control circuitry lockout | Call a pro |
| amber light off | No power to the furnace control | You can often fix it |
| amber light flashing rapidly | Line voltage polarity reversed or the furnace is not grounded | Call a pro |
| steady amber light | Normal, the control has power and no fault to show | You can often fix it |
Models in this range
- 58CTA045-08
- 58CTA045-12
- 58CTA070-08
- 58CTA070-12
- 58CTA070-16
- 58CTA090-14
- 58CTA090-16
- 58CTA090-20
- 58CTA110-12
- 58CTA110-16
- 58CTA110-22
- 58CTA135-16
- 58CTA135-22
- 58CTA155-20
- 58CTX045-08
- 58CTX045-12
- 58CTX070-08
- 58CTX070-12
- 58CTX070-16
- 58CTX090-14
- 58CTX090-16
- 58CTX090-20
- 58CTX110-12
- 58CTX110-16
- 58CTX110-22
- 58CTX135-16
- 58CTX135-22
- 58CTX155-20