1. Home
  2. Carrier
  3. gas furnaces
  4. 59SC5B

Carrier 59SC5B error codes

Every checked code for the Carrier 59SC5B range, with what it means and whether you can fix it yourself.

Error codes

Code Meaning What you can do
11 No previous fault stored You can often fix it
13 Limit circuit lockout (depends on model) Safe checks first, then a pro
14 Ignition lockout after repeated failed lighting attempts Safe checks first, then a pro
21 Gas heating lockout, fault in the gas valve circuit Safe checks first, then a pro
22 Flame sensed while the gas valve is off Safe checks first, then a pro
23 Flue or venting fault (depends on model) Call a pro
24 24-volt fuse on the control has blown Call a pro
31 Flue or venting fault (depends on model) Safe checks first, then a pro
32 Low or low-heat pressure switch did not close, or opened again Safe checks first, then a pro
33 Limit circuit fault, a limit or rollout switch is open Safe checks first, then a pro
34 Flame not proved during ignition Safe checks first, then a pro
45 Control circuitry lockout Call a pro
amber light off No power to the furnace control You can often fix it
amber light flashing rapidly Line voltage polarity reversed or the furnace is not grounded Call a pro
steady amber light Normal, the control has power and no fault to show You can often fix it

Models in this range