Carrier gas furnace code 26.1: Burner thermal switch open, permanent lockout

Gas furnace, Canada and United States

The burner thermal switch (BTS) is open. If it opens during a call for heat the control locks out permanently, and only switching the power off and on clears it.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.

Only some models show this code. Check the list below.

What causes it

  1. A blocked burner inlet or burner mesh.

    Book a licensed gas technician

  2. A power loss during heating that opened the switch.

    Book a licensed gas technician

  3. The manifold pressure or gas firing rate set wrongly.

    Book a licensed gas technician

How to read this code on your unit

The three-digit display sits on the furnace control behind the blower door. Through the sight glass in the door you see only the status light, which flashes the first two digits of the code. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 4 long flashes is a 34.x code. Write down what you see before you open the door or switch the furnace off. The full code with its third digit shows on the control display only with the door removed and the door switch closed, which is a job for a technician. A technician can also look back at the last 7 faults in the FLt menu. Stored codes are erased by themselves after 72 hours, and the display shows non when no fault is stored.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

13 models in 3 ranges
RangeModels
58CU0B58CU0B040C17-12, 58CU0B060C17-16, 58CU0B080C21-20, 58CU0B100C21-20
58SU0B58SU0B040M17-12, 58SU0B060M17-16, 58SU0B080M21-20, 58SU0B100M21-20
59SU5B59SU5B040M17-12, 59SU5B060M17-16, 59SU5B080M21-20, 59SU5B100M21-20, 59SU5B100M21-22

Where this comes from

Checked against the manufacturer's manual on 11 October 2026.

Report a mistake on this page

Other Carrier gas furnace codes

Code Meaning What you can do
13 Limit circuit lockout (depends on model) Safe checks first, then a pro
26 Burner thermal switch open Call a pro
33 Limit circuit fault, a limit or rollout switch is open Safe checks first, then a pro
13.1 Limit circuit lockout, a limit or rollout switch stayed open Safe checks first, then a pro
25.5 Installer settings are corrupted Call a pro
25.6 Wrong program loaded for this control Call a pro
25.7 Non-condensing program in a condensing furnace Call a pro
26.2 Burner thermal switch open, permanent lockout Call a pro
27.1 Program in super plug is missing or corrupted Call a pro
27.2 Program in super plug is missing or corrupted Call a pro
33.1 Limit circuit switch open, blower running to cool the furnace Safe checks first, then a pro
33.2 High heat only for the current cycle Safe checks first, then a pro

See all overheat codes on gas furnaces across brands.