- Home
- Carrier
- gas furnaces
- 58SU0B
Carrier 58SU0B error codes
Every checked code for the Carrier 58SU0B range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| 10.1 | Line voltage polarity reversed | Call a pro |
| 13.1 | Limit circuit lockout, a limit or rollout switch stayed open | Safe checks first, then a pro |
| 14.1 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 14.2 | Flame lost 3 times after 70 seconds of heating | Safe checks first, then a pro |
| 14.3 | Lockout after 7 flame losses in one heat request | Safe checks first, then a pro |
| 14.4 | Lockout after repeated pressure switch openings | Safe checks first, then a pro |
| 21.1 | 24 volts sensed at the gas valve when there should be none | Safe checks first, then a pro |
| 22.1 | Flame proved while the gas valve is off | Safe checks first, then a pro |
| 23.3 | Pressure transducer senses over-pressure | Call a pro |
| 24.1 | Fuse fault, short in the 24-volt wiring | Call a pro |
| 25.1 | Control has no program loaded | Call a pro |
| 25.2 | Control program file is corrupted | Call a pro |
| 25.3 | Twinned furnaces are not identical | Call a pro |
| 25.4 | Main program invalid, running on the backup program | Call a pro |
| 25.5 | Installer settings are corrupted | Call a pro |
| 25.6 | Wrong program loaded for this control | Call a pro |
| 26.1 | Burner thermal switch open, permanent lockout | Call a pro |
| 27.1 | Program in super plug is missing or corrupted | Call a pro |
| 27.2 | Program in super plug is missing or corrupted | Call a pro |
| 27.3 | Program in super plug is missing or corrupted | Call a pro |
| 31.4 | Loss of pressure before the blower started | Safe checks first, then a pro |
| 31.5 | Loss of pressure after the blower started | Safe checks first, then a pro |
| 34.1 | Ignition fault, burners did not light in 4 trials | Safe checks first, then a pro |
| 34.2 | Flame lost before the heating blower started | Safe checks first, then a pro |
| 34.3 | Flame lost after the heating blower started | Safe checks first, then a pro |
| 34.4 | Flame lost at reduced inducer pressure or in Self Healing mode | Safe checks first, then a pro |
| 42.1 | No inducer speed at start-up | Call a pro |
| 42.2 | Inducer speed lost while running | Call a pro |
| 42.3 | Inducer over its speed limit | Call a pro |
| 45.1 | Internal control fault | Call a pro |
| 45.2 | Gas valve relay will not close | Call a pro |
| 45.3 | Control memory (EEPROM) fault | Call a pro |
| 46.1 | Momentary loss of power | Call a pro |
Models in this range
- 58SU0B040M17-12
- 58SU0B060M17-16
- 58SU0B080M21-20
- 58SU0B100M21-20