- Home
- Carrier
- gas furnaces
- Code 22.1
Carrier gas furnace code 22.1: Flame proved while the gas valve is off
Gas furnace, Canada and United States
The control proved a flame while the gas valve was de-energized. The inducer keeps running until the fault clears. Shut the gas off first, then book a technician.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
A gas valve that is stuck open or leaking.
Shut off the gas to the furnace, then the powerYou can do this
- Set the thermostat to its lowest setting and its mode to OFF. If you smell gas, stop. Do not light any appliance, touch any electrical switch or use a phone in the building. Leave and call your gas supplier from a neighbor's phone.
- Close the manual gas valve in the gas pipe to the furnace.
- Only then turn off the electrical supply to the furnace. Carrier says to shut off the gas first whenever the gas does not shut off or the furnace overheats.
- Leave the furnace off with its doors on and call your dealer for service.
- Set the thermostat to its lowest setting and its mode to OFF.
How to read this code on your unit
The three-digit display sits on the furnace control behind the blower door. Through the sight glass in the door you see only the status light, which flashes the first two digits of the code. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is a 33.x code. Write down what you see before you open the door or switch the furnace off. The full code with its third digit shows on the control display only with the door removed and the door switch closed, which is a job for a technician. A technician can also look back at the last 7 faults in the FLt menu. Stored codes are erased by themselves after 72 hours of powered operation after the last fault, and the display shows non when no fault is stored.
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
164 models in 16 ranges
| Range | Models |
|---|---|
| 58SB0B/58SB1B | 58SB0B045M14-12, 58SB0B045M17-14, 58SB0B070M14-12, 58SB0B070M17-12, 58SB0B070M17-16, 58SB0B070M21-16, 58SB0B090M17-14, 58SB0B090M21-16, 58SB0B090M21-20, 58SB0B090M24-20, 58SB0B110M21-20, 58SB0B110M24-20, 58SB0B135M24-20, 58SB0B155M24-20, 58SB1B045M14-12, 58SB1B045M17-14, 58SB1B070M14-12, 58SB1B070M17-12, 58SB1B070M17-16, 58SB1B070M21-16, 58SB1B090M17-14, 58SB1B090M21-16, 58SB1B090M21-20, 58SB1B090M24-20, 58SB1B110M21-20, 58SB1B110M24-20, 58SB1B135M24-20, 58SB1B155M24-20 |
| 58SC0B/58SC1B | 58SC0B045M14-12, 58SC0B045M17-14, 58SC0B070M14-12, 58SC0B070M17-12, 58SC0B070M17-16, 58SC0B070M21-16, 58SC0B090M17-14, 58SC0B090M21-16, 58SC0B090M21-20, 58SC0B110M21-20, 58SC0B110M24-20, 58SC0B135M24-20, 58SC1B045M14-12, 58SC1B045M17-14, 58SC1B070M14-12, 58SC1B070M17-12, 58SC1B070M17-16, 58SC1B070M21-16, 58SC1B090M17-14, 58SC1B090M21-16, 58SC1B090M21-20, 58SC1B110M21-20, 58SC1B110M24-20, 58SC1B135M24-20 |
| 58SP0B/58SP1B | 58SP0B045V14-12, 58SP0B070V14-12, 58SP0B070V17-16, 58SP0B090V17-16, 58SP0B090V21-20, 58SP0B110V21-22, 58SP0B135V24-22, 58SP1B045V14-12, 58SP1B070V14-12, 58SP1B070V17-16, 58SP1B090V17-16, 58SP1B090V21-20, 58SP1B110V21-22, 58SP1B135V24-22 |
| 58TN0B/58TN1B | 58TN0B045C17-12, 58TN0B070C14-12, 58TN0B070C17-16, 58TN0B070C21-20, 58TN0B090C17-16, 58TN0B090C21-20, 58TN0B110C21-20, 58TN0B135C24-22, 58TN1B045C17-12, 58TN1B070C14-12, 58TN1B070C17-16, 58TN1B070C21-20, 58TN1B090C17-16, 58TN1B090C21-20, 58TN1B110C21-20, 58TN1B135C24-22 |
| 58TP0B/58TP1B | 58TP0B045V14-12, 58TP0B070V14-12, 58TP0B070V17-16, 58TP0B090V17-16, 58TP0B090V21-20, 58TP0B110V21-22, 58TP0B135V24-22, 58TP1B045V14-12, 58TP1B070V14-12, 58TP1B070V17-16, 58TP1B090V17-16, 58TP1B090V21-20, 58TP1B110V21-22, 58TP1B135V24-22 |
| 59SC2E | 59SC2E040M14-12, 59SC2E040M17-12, 59SC2E060M14-12, 59SC2E060M17-14, 59SC2E080M17-16, 59SC2E080M21-20, 59SC2E100M21-20, 59SC2E100M21-22, 59SC2E120M24-20 |
| 59SC6A | 59SC6A026M14-10, 59SC6A040M14-10, 59SC6A040M17-12, 59SC6A060M14-12, 59SC6A060M17-16, 59SC6A080M17-16, 59SC6A080M21-20, 59SC6A100M21-20, 59SC6A100M21-22, 59SC6A120M24-22, 59SC6A140M24-22 |
| 59TN6C | 59TN6C040C14-10, 59TN6C060C17-14, 59TN6C080C17-14, 59TN6C080C21-20, 59TN6C100C21-22, 59TN6C120C24-22 |
| 59TN7A | 59TN7A060C17-16, 59TN7A080C17-16, 59TN7A080C21-20, 59TN7A100C21-22, 59TN7A120C24-22 |
| 59TP6C | 59TP6C040V14-10, 59TP6C040V17-12, 59TP6C060V14-12, 59TP6C060V17-16, 59TP6C080V17-16, 59TP6C080V21-20, 59TP6C100V21-20, 59TP6C100V21-22, 59TP6C120V24-22 |
| 59TP7A | 59TP7A060V17-16, 59TP7A080V17-16, 59TP7A080V21-20, 59TP7A100V21-20, 59TP7A100V21-22, 59TP7A120V24-22 |
| 58CU0B | 58CU0B040C17-12, 58CU0B060C17-16, 58CU0B080C21-20, 58CU0B100C21-20 |
| 58SU0B | 58SU0B040M17-12, 58SU0B060M17-16, 58SU0B080M21-20, 58SU0B100M21-20 |
| 59CU5B | 59CU5B060C17-16, 59CU5B080C21-20, 59CU5B100C21-22 |
| 59SU5B | 59SU5B040M17-12, 59SU5B060M17-16, 59SU5B080M21-20, 59SU5B100M21-20, 59SU5B100M21-22 |
| 59MN7C | 59MN7C060C17-14, 59MN7C060C21-20, 59MN7C080C17-14, 59MN7C080C21-20, 59MN7C100C21-22, 59MN7C120C24-22 |
Where this comes from
- 58SB0B gas furnace, installation, start-up, operating and service instructions (58SB0B-01SI) , page 31
- 59TP6C gas furnace, installation, start-up, operating and service instructions (59TP6C-03SI) , page 56, 76
- 59TN6C gas furnace, installation, start-up, operating and service instructions (59TN6C-04SI) , page 76
- 58SU0B gas furnace, installation, start-up, operating and service instructions (58SU0B-03SI) , page 24, 39
- 59SU5B gas furnace, installation, start-up, operating and service instructions (59SU5B-03SI) , page 48, 63
- 58CU0B gas furnace, installation, start-up, operating and service instructions (58CU0B-03SI) , page 28, 43
- 59CU5B gas furnace, installation, start-up, operating and service instructions (59CU5B-05SI) , page 49, 66
- 59MN7C gas furnace, installation, start-up, operating and service instructions (59MN7C-04SI) , page 53, 74
Checked against the manufacturer's manual on 11 October 2026.
Other Carrier gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| 21 | Gas heating lockout, fault in the gas valve circuit | Safe checks first, then a pro |
| 22 | Flame sensed while the gas valve is off | Safe checks first, then a pro |
| 35 | Modulating gas valve not communicating | Call a pro |
| 15.2 | Blower lockout, blower never reached 500 rpm | Call a pro |
| 17.1 | Lost communication with the Bluetooth module | Call a pro |
| 19.1 | Lost InteliSense communication with the thermostat | Call a pro |
| 21.1 | 24 volts sensed at the gas valve when there should be none | Safe checks first, then a pro |
| 23.1 | Flue or venting fault (depends on model) | Call a pro |
| 23.2 | Secondary pressure switch stuck closed | Call a pro |
| 23.3 | Pressure transducer senses over-pressure | Call a pro |
| 23.4 | Low pressure switch stuck closed | Call a pro |
| 35.1 | Modulating gas valve not communicating | Call a pro |
See all gas valve fault codes on gas furnaces across brands.