Carrier 59MN7C error codes
Every checked code for the Carrier 59MN7C range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| 10.1 | Line voltage polarity reversed | Call a pro |
| 10.2 | Refrigerant leak detected, dissipation active | Call a pro |
| 13.1 | Limit circuit lockout, a limit or rollout switch stayed open | Safe checks first, then a pro |
| 14.1 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 14.2 | Flame lost 3 times after 70 seconds of heating | Safe checks first, then a pro |
| 14.3 | Lockout after 7 flame losses in one heat request | Safe checks first, then a pro |
| 14.4 | Lockout after repeated pressure switch openings | Safe checks first, then a pro |
| 15.1 | Blower lockout, no blower speed signal | Call a pro |
| 15.2 | Blower lockout, blower never reached 500 rpm | Call a pro |
| 17.1 | Lost communication with the Bluetooth module | Call a pro |
| 21.1 | 24 volts sensed at the gas valve when there should be none | Safe checks first, then a pro |
| 22.1 | Flame proved while the gas valve is off | Safe checks first, then a pro |
| 23.4 | Low pressure switch stuck closed | Call a pro |
| 23.5 | High pressure switch stuck closed | Call a pro |
| 23.6 | Medium pressure switch stuck closed | Call a pro |
| 24.1 | Fuse fault, short in the 24-volt wiring | Call a pro |
| 25.1 | Control has no program loaded | Call a pro |
| 25.2 | Control program file is corrupted | Call a pro |
| 25.4 | Main program invalid, running on the backup program | Call a pro |
| 25.5 | Installer settings are corrupted | Call a pro |
| 25.6 | Wrong program loaded for this control | Call a pro |
| 27.1 | Program in super plug is missing or corrupted | Call a pro |
| 27.2 | Program in super plug is missing or corrupted | Call a pro |
| 27.3 | Program in super plug is missing or corrupted | Call a pro |
| 31.1 | Flue or venting fault (depends on model) | Depends on your model |
| 31.2 | Flue or venting fault (depends on model) | Depends on your model |
| 31.6 | High pressure switch open | Safe checks first, then a pro |
| 32.2 | Low pressure switch open | Safe checks first, then a pro |
| 33.1 | Limit circuit switch open, blower running to cool the furnace | Safe checks first, then a pro |
| 34.1 | Ignition fault, burners did not light in 4 trials | Safe checks first, then a pro |
| 34.5 | Low heat flame lost before the blower started | Safe checks first, then a pro |
| 34.6 | Low heat flame lost after the blower started | Safe checks first, then a pro |
| 34.7 | High heat flame lost before the blower started | Safe checks first, then a pro |
| 34.8 | High heat flame lost after the blower started | Safe checks first, then a pro |
| 35.1 | Modulating gas valve not communicating | Call a pro |
| 41.1 | No blower speed at start-up | Call a pro |
| 41.2 | Blower speed lost while running | Call a pro |
| 41.3 | Blower not reaching 500 rpm | Call a pro |
| 42.1 | No inducer speed at start-up | Call a pro |
| 42.2 | Inducer speed lost while running | Call a pro |
| 42.3 | Inducer over its speed limit | Call a pro |
| 43.1 | High switch closed before the low switch | Call a pro |
| 45.1 | Internal control fault | Call a pro |
| 45.2 | Gas valve relay will not close | Call a pro |
| 45.3 | Control memory (EEPROM) fault | Call a pro |
| 45.4 | Microprocessor communication lost | Call a pro |
| 51.1 | Outdoor air sensor open | Call a pro |
| 51.2 | Outdoor air sensor shorted | Call a pro |
| 52.1 | Supply air sensor open | Call a pro |
| 52.2 | Supply air sensor shorted | Call a pro |
| 53.1 | Return air sensor open | Call a pro |
| 53.2 | Return air sensor shorted | Call a pro |
| btL | Firmware failed to load | Call a pro |