Carrier gas furnace code 53.2: Return air sensor shorted

Gas furnace, Canada and United States

The return air temperature (RAT) sensor is shorted.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

Only some models show this code. Check the list below.

What causes it

InteliSense display furnaces

  1. A technician can check the return air sensor plug and connection at the control board.

    Book a licensed gas technician

  2. A damaged return air sensor.

    Book a licensed gas technician

InteliSense ultra-low NOx furnaces, InteliSense modulating furnaces

  1. The return air sensor is not firmly plugged into the control board.

    Book a licensed gas technician

  2. A damaged return air sensor.

    Book a licensed gas technician

How to read this code on your unit

The three-digit display sits on the furnace control behind the blower door. Through the sight glass in the door you see only the status light, which flashes the first two digits of the code. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is a 33.x code. Write down what you see before you open the door or switch the furnace off. The full code with its third digit shows on the control display only with the door removed and the door switch closed, which is a job for a technician. A technician can also look back at the last 7 faults in the FLt menu. Stored codes are erased by themselves after 72 hours of powered operation after the last fault, and the display shows non when no fault is stored.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

83 models in 10 ranges
RangeModels
58SP0B/58SP1B58SP0B045V14-12, 58SP0B070V14-12, 58SP0B070V17-16, 58SP0B090V17-16, 58SP0B090V21-20, 58SP0B110V21-22, 58SP0B135V24-22, 58SP1B045V14-12, 58SP1B070V14-12, 58SP1B070V17-16, 58SP1B090V17-16, 58SP1B090V21-20, 58SP1B110V21-22, 58SP1B135V24-22
58TN0B/58TN1B58TN0B045C17-12, 58TN0B070C14-12, 58TN0B070C17-16, 58TN0B070C21-20, 58TN0B090C17-16, 58TN0B090C21-20, 58TN0B110C21-20, 58TN0B135C24-22, 58TN1B045C17-12, 58TN1B070C14-12, 58TN1B070C17-16, 58TN1B070C21-20, 58TN1B090C17-16, 58TN1B090C21-20, 58TN1B110C21-20, 58TN1B135C24-22
58TP0B/58TP1B58TP0B045V14-12, 58TP0B070V14-12, 58TP0B070V17-16, 58TP0B090V17-16, 58TP0B090V21-20, 58TP0B110V21-22, 58TP0B135V24-22, 58TP1B045V14-12, 58TP1B070V14-12, 58TP1B070V17-16, 58TP1B090V17-16, 58TP1B090V21-20, 58TP1B110V21-22, 58TP1B135V24-22
59TN6C59TN6C040C14-10, 59TN6C060C17-14, 59TN6C080C17-14, 59TN6C080C21-20, 59TN6C100C21-22, 59TN6C120C24-22
59TN7A59TN7A060C17-16, 59TN7A080C17-16, 59TN7A080C21-20, 59TN7A100C21-22, 59TN7A120C24-22
59TP6C59TP6C040V14-10, 59TP6C040V17-12, 59TP6C060V14-12, 59TP6C060V17-16, 59TP6C080V17-16, 59TP6C080V21-20, 59TP6C100V21-20, 59TP6C100V21-22, 59TP6C120V24-22
59TP7A59TP7A060V17-16, 59TP7A080V17-16, 59TP7A080V21-20, 59TP7A100V21-20, 59TP7A100V21-22, 59TP7A120V24-22
58CU0B58CU0B040C17-12, 58CU0B060C17-16, 58CU0B080C21-20, 58CU0B100C21-20
59CU5B59CU5B060C17-16, 59CU5B080C21-20, 59CU5B100C21-22
59MN7C59MN7C060C17-14, 59MN7C060C21-20, 59MN7C080C17-14, 59MN7C080C21-20, 59MN7C100C21-22, 59MN7C120C24-22

Where this comes from

Checked against the manufacturer's manual on 11 October 2026.

Report a mistake on this page

Other Carrier gas furnace codes

Code Meaning What you can do
45.3 Control memory (EEPROM) fault Call a pro
45.4 Microprocessor communication lost Call a pro
46.1 Momentary loss of power Call a pro
51.1 Outdoor air sensor open Call a pro
51.2 Outdoor air sensor shorted Call a pro
52.1 Supply air sensor open Call a pro
52.2 Supply air sensor shorted Call a pro
53.1 Return air sensor open Call a pro
btL Firmware failed to load Call a pro
amber light off No power to the furnace control You can often fix it
amber light flashing rapidly Line voltage polarity reversed or the furnace is not grounded Call a pro
steady amber light Normal, the control has power and no fault to show You can often fix it

See all temperature sensor fault codes on gas furnaces across brands.