Carrier gas furnace code 45.3: Control memory (EEPROM) fault

Gas furnace, Canada and United States

The control found an EEPROM memory fault. The 58SB0B, 58SC0B, 59SC2E and 59SC6A labels call it an EEPROM memory issue, while the 58SP0B, 59TP6C, 59TP7A, 58TP0B, 59TN6C, 58TN0B and 59TN7A labels call it a micro EEPROM error. The 59TN6C, 58TN0B and 59TN7A labels mark it 1hr. To clear it, cycle the power; if it comes back, the control must be replaced.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

What causes it

  1. An EEPROM memory fault on the furnace control. A technician cycles the power, and replaces the control if the code repeats.

    Book a licensed gas technician

How to read this code on your unit

The three-digit display sits on the furnace control behind the blower door. Through the sight glass in the door you see only the status light, which flashes the first two digits of the code. Count the short flashes for the first digit, then the long flashes for the second, so 3 short flashes followed by 3 long flashes is a 33.x code. Write down what you see before you open the door or switch the furnace off. The full code with its third digit shows on the control display only with the door removed and the door switch closed, which is a job for a technician. A technician can also look back at the last 7 faults in the FLt menu. Stored codes are erased by themselves after 72 hours of powered operation after the last fault, and the display shows non when no fault is stored.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

164 models in 16 ranges
RangeModels
58SB0B/58SB1B58SB0B045M14-12, 58SB0B045M17-14, 58SB0B070M14-12, 58SB0B070M17-12, 58SB0B070M17-16, 58SB0B070M21-16, 58SB0B090M17-14, 58SB0B090M21-16, 58SB0B090M21-20, 58SB0B090M24-20, 58SB0B110M21-20, 58SB0B110M24-20, 58SB0B135M24-20, 58SB0B155M24-20, 58SB1B045M14-12, 58SB1B045M17-14, 58SB1B070M14-12, 58SB1B070M17-12, 58SB1B070M17-16, 58SB1B070M21-16, 58SB1B090M17-14, 58SB1B090M21-16, 58SB1B090M21-20, 58SB1B090M24-20, 58SB1B110M21-20, 58SB1B110M24-20, 58SB1B135M24-20, 58SB1B155M24-20
58SC0B/58SC1B58SC0B045M14-12, 58SC0B045M17-14, 58SC0B070M14-12, 58SC0B070M17-12, 58SC0B070M17-16, 58SC0B070M21-16, 58SC0B090M17-14, 58SC0B090M21-16, 58SC0B090M21-20, 58SC0B110M21-20, 58SC0B110M24-20, 58SC0B135M24-20, 58SC1B045M14-12, 58SC1B045M17-14, 58SC1B070M14-12, 58SC1B070M17-12, 58SC1B070M17-16, 58SC1B070M21-16, 58SC1B090M17-14, 58SC1B090M21-16, 58SC1B090M21-20, 58SC1B110M21-20, 58SC1B110M24-20, 58SC1B135M24-20
58SP0B/58SP1B58SP0B045V14-12, 58SP0B070V14-12, 58SP0B070V17-16, 58SP0B090V17-16, 58SP0B090V21-20, 58SP0B110V21-22, 58SP0B135V24-22, 58SP1B045V14-12, 58SP1B070V14-12, 58SP1B070V17-16, 58SP1B090V17-16, 58SP1B090V21-20, 58SP1B110V21-22, 58SP1B135V24-22
58TN0B/58TN1B58TN0B045C17-12, 58TN0B070C14-12, 58TN0B070C17-16, 58TN0B070C21-20, 58TN0B090C17-16, 58TN0B090C21-20, 58TN0B110C21-20, 58TN0B135C24-22, 58TN1B045C17-12, 58TN1B070C14-12, 58TN1B070C17-16, 58TN1B070C21-20, 58TN1B090C17-16, 58TN1B090C21-20, 58TN1B110C21-20, 58TN1B135C24-22
58TP0B/58TP1B58TP0B045V14-12, 58TP0B070V14-12, 58TP0B070V17-16, 58TP0B090V17-16, 58TP0B090V21-20, 58TP0B110V21-22, 58TP0B135V24-22, 58TP1B045V14-12, 58TP1B070V14-12, 58TP1B070V17-16, 58TP1B090V17-16, 58TP1B090V21-20, 58TP1B110V21-22, 58TP1B135V24-22
59SC2E59SC2E040M14-12, 59SC2E040M17-12, 59SC2E060M14-12, 59SC2E060M17-14, 59SC2E080M17-16, 59SC2E080M21-20, 59SC2E100M21-20, 59SC2E100M21-22, 59SC2E120M24-20
59SC6A59SC6A026M14-10, 59SC6A040M14-10, 59SC6A040M17-12, 59SC6A060M14-12, 59SC6A060M17-16, 59SC6A080M17-16, 59SC6A080M21-20, 59SC6A100M21-20, 59SC6A100M21-22, 59SC6A120M24-22, 59SC6A140M24-22
59TN6C59TN6C040C14-10, 59TN6C060C17-14, 59TN6C080C17-14, 59TN6C080C21-20, 59TN6C100C21-22, 59TN6C120C24-22
59TN7A59TN7A060C17-16, 59TN7A080C17-16, 59TN7A080C21-20, 59TN7A100C21-22, 59TN7A120C24-22
59TP6C59TP6C040V14-10, 59TP6C040V17-12, 59TP6C060V14-12, 59TP6C060V17-16, 59TP6C080V17-16, 59TP6C080V21-20, 59TP6C100V21-20, 59TP6C100V21-22, 59TP6C120V24-22
59TP7A59TP7A060V17-16, 59TP7A080V17-16, 59TP7A080V21-20, 59TP7A100V21-20, 59TP7A100V21-22, 59TP7A120V24-22
58CU0B58CU0B040C17-12, 58CU0B060C17-16, 58CU0B080C21-20, 58CU0B100C21-20
58SU0B58SU0B040M17-12, 58SU0B060M17-16, 58SU0B080M21-20, 58SU0B100M21-20
59CU5B59CU5B060C17-16, 59CU5B080C21-20, 59CU5B100C21-22
59SU5B59SU5B040M17-12, 59SU5B060M17-16, 59SU5B080M21-20, 59SU5B100M21-20, 59SU5B100M21-22
59MN7C59MN7C060C17-14, 59MN7C060C21-20, 59MN7C080C17-14, 59MN7C080C21-20, 59MN7C100C21-22, 59MN7C120C24-22

Where this comes from

Checked against the manufacturer's manual on 11 October 2026.

Report a mistake on this page

Other Carrier gas furnace codes

Code Meaning What you can do
45 Control circuitry lockout Call a pro
42.1 No inducer speed at start-up Call a pro
42.2 Inducer speed lost while running Call a pro
42.3 Inducer over its speed limit Call a pro
43.1 High switch closed before the low switch Call a pro
45.1 Internal control fault Call a pro
45.2 Gas valve relay will not close Call a pro
45.4 Microprocessor communication lost Call a pro
46.1 Momentary loss of power Call a pro
51.1 Outdoor air sensor open Call a pro
51.2 Outdoor air sensor shorted Call a pro
52.1 Supply air sensor open Call a pro

See all control board fault codes on gas furnaces across brands.