1. Home
  2. Carrier
  3. gas furnaces
  4. 59TP7A

Carrier 59TP7A error codes

Every checked code for the Carrier 59TP7A range, with what it means and whether you can fix it yourself.

Error codes

Code Meaning What you can do
10.1 Line voltage polarity reversed Call a pro
13.1 Limit circuit lockout, a limit or rollout switch stayed open Safe checks first, then a pro
14.1 Ignition lockout after repeated failed lighting attempts Safe checks first, then a pro
14.2 Flame lost 3 times after 70 seconds of heating Safe checks first, then a pro
14.3 Lockout after 7 flame losses in one heat request Safe checks first, then a pro
14.4 Lockout after repeated pressure switch openings Safe checks first, then a pro
15.1 Blower lockout, no blower speed signal Call a pro
19.1 Lost InteliSense communication with the thermostat Call a pro
21.1 24 volts sensed at the gas valve when there should be none Safe checks first, then a pro
22.1 Flame proved while the gas valve is off Safe checks first, then a pro
23.4 Low pressure switch stuck closed Call a pro
23.5 High pressure switch stuck closed Call a pro
24.1 Fuse fault, short in the 24-volt wiring Call a pro
25.1 Control has no program loaded Call a pro
25.2 Control program file is corrupted Call a pro
25.3 Twinned furnaces are not identical Call a pro
25.4 Main program invalid, running on the backup program Call a pro
25.5 Installer settings are corrupted Call a pro
25.6 Wrong program loaded for this control Call a pro
27.1 Program in super plug is missing or corrupted Call a pro
27.2 Program in super plug is missing or corrupted Call a pro
27.3 Program in super plug is missing or corrupted Call a pro
31.6 High pressure switch open Safe checks first, then a pro
31.7 High heat only, high switch failed to close in time Safe checks first, then a pro
32.2 Low pressure switch open Safe checks first, then a pro
33.1 Limit circuit switch open, blower running to cool the furnace Safe checks first, then a pro
33.2 High heat only for the current cycle Safe checks first, then a pro
34.1 Ignition fault, burners did not light in 4 trials Safe checks first, then a pro
34.5 Low heat flame lost before the blower started Safe checks first, then a pro
34.6 Low heat flame lost after the blower started Safe checks first, then a pro
34.7 High heat flame lost before the blower started Safe checks first, then a pro
34.8 High heat flame lost after the blower started Safe checks first, then a pro
41.1 No blower speed at start-up Call a pro
41.2 Blower speed lost while running Call a pro
43.1 High switch closed before the low switch Call a pro
45.1 Internal control fault Call a pro
45.2 Gas valve relay will not close Call a pro
45.3 Control memory (EEPROM) fault Call a pro
45.4 Microprocessor communication lost Call a pro
46.1 Momentary loss of power Call a pro
52.1 Supply air sensor open Call a pro
52.2 Supply air sensor shorted Call a pro
53.1 Return air sensor open Call a pro
53.2 Return air sensor shorted Call a pro

Models in this range