- Home
- Carrier
- gas furnaces
- 59SC6A
Carrier 59SC6A error codes
Every checked code for the Carrier 59SC6A range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| 10.1 | Line voltage polarity reversed | Call a pro |
| 13.1 | Limit circuit lockout, a limit or rollout switch stayed open | Safe checks first, then a pro |
| 14.1 | Ignition lockout after repeated failed lighting attempts | Safe checks first, then a pro |
| 14.2 | Flame lost 3 times after 70 seconds of heating | Safe checks first, then a pro |
| 14.3 | Lockout after 7 flame losses in one heat request | Safe checks first, then a pro |
| 21.1 | 24 volts sensed at the gas valve when there should be none | Safe checks first, then a pro |
| 22.1 | Flame proved while the gas valve is off | Safe checks first, then a pro |
| 23.1 | Flue or venting fault (depends on model) | Call a pro |
| 23.2 | Secondary pressure switch stuck closed | Call a pro |
| 24.1 | Fuse fault, short in the 24-volt wiring | Call a pro |
| 25.1 | Control has no program loaded | Call a pro |
| 25.2 | Control program file is corrupted | Call a pro |
| 25.3 | Twinned furnaces are not identical | Call a pro |
| 25.4 | Main program invalid, running on the backup program | Call a pro |
| 25.5 | Installer settings are corrupted | Call a pro |
| 25.6 | Wrong program loaded for this control | Call a pro |
| 25.7 | Non-condensing program in a condensing furnace | Call a pro |
| 27.1 | Program in super plug is missing or corrupted | Call a pro |
| 27.2 | Program in super plug is missing or corrupted | Call a pro |
| 27.3 | Program in super plug is missing or corrupted | Call a pro |
| 31.2 | Flue or venting fault (depends on model) | Depends on your model |
| 31.3 | Secondary pressure switch lockout after 3 failed trials | Safe checks first, then a pro |
| 32.1 | Main pressure switch (LPS) open | Safe checks first, then a pro |
| 33.1 | Limit circuit switch open, blower running to cool the furnace | Safe checks first, then a pro |
| 34.1 | Ignition fault, burners did not light in 4 trials | Safe checks first, then a pro |
| 34.2 | Flame lost before the heating blower started | Safe checks first, then a pro |
| 34.3 | Flame lost after the heating blower started | Safe checks first, then a pro |
| 45.1 | Internal control fault | Call a pro |
| 45.2 | Gas valve relay will not close | Call a pro |
| 45.3 | Control memory (EEPROM) fault | Call a pro |
| 46.1 | Momentary loss of power | Call a pro |
Models in this range
- 59SC6A026M14-10
- 59SC6A040M14-10
- 59SC6A040M17-12
- 59SC6A060M14-12
- 59SC6A060M17-16
- 59SC6A080M17-16
- 59SC6A080M21-20
- 59SC6A100M21-20
- 59SC6A100M21-22
- 59SC6A120M24-22
- 59SC6A140M24-22