1. Home
  2. Overheat: gas furnace codes by brand

Overheat: gas furnace codes by brand

A temperature limit inside the appliance was exceeded and it shut down to protect itself.

Brand Code Meaning What you can do
Carrier 13 Limit circuit lockout (depends on model) Safe checks first, then a pro
Carrier 26 Burner thermal switch open Call a pro
Carrier 33 Limit circuit fault, a limit or rollout switch is open Safe checks first, then a pro
Carrier 13.1 Limit circuit lockout, a limit or rollout switch stayed open Safe checks first, then a pro
Carrier 26.1 Burner thermal switch open, permanent lockout Call a pro
Carrier 26.2 Burner thermal switch open, permanent lockout Call a pro
Carrier 33.1 Limit circuit switch open, blower running to cool the furnace Safe checks first, then a pro
Carrier 33.2 High heat only for the current cycle Safe checks first, then a pro
Goodman E3 Overheat (depends on model) Safe checks first, then a pro
Goodman E11 Rollout switch open Call a pro
Goodman Ed Manual-reset rollout switch open Call a pro
Goodman EE3 Primary limit switch open Safe checks first, then a pro
Goodman EEd Auxiliary limit switch open (blower compartment) Safe checks first, then a pro
Goodman 4 red flashes Overheat (depends on model) Safe checks first, then a pro
Goodman 5 red flashes Sensor fault or overheat (depends on model) Safe checks first, then a pro
Goodman 6 red flashes Overheat / flue or venting fault (depends on model) Depends on your model
Goodman 11 red flashes Ignition failure or overheat (depends on model) Call a pro