Goodman gas furnace 11 red flashes: Ignition failure or overheat
Gas furnace, Canada and United States
This code means one of two things, depending on your model. Find your model family below, then read the section for it. The model number is on the rating label on the side of the unit.
Find your model family
| If you have | It means |
|---|---|
| GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96 | Igniter open circuit |
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | Limit open more than 5 minutes (blower failure suspected) |
Igniter open circuit
On GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96.
The control found the igniter circuit open, and the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
The igniter is connected wrongly or the wiring from the control board to it is faulty.
-
The igniter has failed.
-
A poor unit ground or burner ground.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
75 models in 3 ranges
| Range | Models |
|---|---|
| GMES80 / GCES80 / AMES80 / ACES80 | GMES800403AN, GMES800403AX, GMES800603AN, GMES800603AX, GMES800603BN, GMES800603BX, GMES800604BN, GMES800604BX, GMES800803BN, GMES800803BX, GMES800804BN, GMES800804BX, GMES800804CN, GMES800804CX, GMES800805CN, GMES800805CX, GMES801005CN, GMES801005CX, GMES801205DN, AMES800403AX, AMES800603AX, AMES800603BN, AMES800604BX, AMES800803BX, AMES800804BX, AMES800804CX, AMES800805CX, AMES801005CX, AMES801205DX, GCES800403AN, GCES800403AX, GCES800603AN, GCES800603AX, GCES800804BN, GCES800804BX, GCES801005CN, GCES801005CX, ACES800403AN, ACES800403AX, ACES800603AN, ACES800603AX, ACES800804BX, ACES801005CX |
| GMES92 | GMES920403AN, GMES920603BN, GMES920803BN, GMES920804CN, GMES920805CN, GMES921004CN, GMES921005CN, GMES921205DN |
| GMES96 / GCES96 / AMES96 / ACES96 | GMES960403AN, GMES960603BN, GMES960803BN, GMES960804CN, GMES960805CN, GMES961005CN, GMES961205DN, AMES960403AN, AMES960603BN, AMES960803BN, AMES960804CN, AMES960805CN, AMES961005CN, AMES961205DN, GCES960403BN, GCES960603BN, GCES960804CN, GCES961005CN, GCES961205DN, ACES960403BN, ACES960603BN, ACES960804CN, ACES961005CN, ACES961205DN |
Where this comes from
- GMES80 gas furnace installation instructions (IOG-2021H) , page 31
- GMES92/GMES96 gas furnace installation instructions (IOG-2020J) , page 42
Checked against the manufacturer's manual on 9 October 2026.
Limit open more than 5 minutes (blower failure suspected)
On GMEC96 / GCEC96 / AMEC96 / ACEC96.
The limit circuit has been open for more than five minutes, so the control assumes the indoor blower has failed. The inducer keeps running and the furnace does not heat.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
The indoor blower is not running. A technician resets the main power and checks the blower.
-
A manual-reset rollout switch or limit has opened. A technician finds out why and resets it.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
- GMEC96 two-stage gas furnace installation instructions (IOG-2011U) , page 50, 55, 56
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| EE3 | Primary limit switch open | Safe checks first, then a pro |
| EE7 | Igniter circuit problem | Call a pro |
| EEd | Auxiliary limit switch open (blower compartment) | Safe checks first, then a pro |
| EEL | Igniter circuit problem | Call a pro |
| EEn | Igniter open | Call a pro |
| 1 red flash | Ignition failure or gas valve fault (depends on model) | Safe checks first, then a pro |
| 4 red flashes | Overheat (depends on model) | Safe checks first, then a pro |
| 5 red flashes | Sensor fault or overheat (depends on model) | Safe checks first, then a pro |
| 6 red flashes | Overheat / flue or venting fault (depends on model) | Depends on your model |
| 7 red flashes | Flame loss or ignition failure (depends on model) | Depends on your model |
| 8 red flashes | Ignition failure or flame loss (depends on model) | Depends on your model |
| 12 red flashes | Flue or venting fault / ignition failure (depends on model) | Call a pro |
See all ignition failure codes on gas furnaces across brands.
See all overheat codes on gas furnaces across brands.