- Home
- Goodman
- gas furnaces
- 8 red flashes
Goodman gas furnace 8 red flashes: Ignition failure or flame loss
Gas furnace, Canada and United States
This code means one of two things, depending on your model. Find your model family below, then read the section for it. The model number is on the rating label on the side of the unit.
Find your model family
| If you have | It means |
|---|---|
| GDH8, GDS8, GMH8 / AMH8, GMH95 / GCH95 / AMH95, GMS8 / AMS8, GMSS92 / GCSS92 / AMSS92, GMSS96 / GCSS96 / AMSS96 / ACSS96, GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96 | Igniter circuit or grounding problem |
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | Lockout, flame lost after lighting |
Igniter circuit or grounding problem
On GDH8, GDS8, GMH8 / AMH8, GMH95 / GCH95 / AMH95, GMS8 / AMS8, GMSS92 / GCSS92 / AMSS92, GMSS96 / GCSS96 / AMSS96 / ACSS96, GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96.
The control found a problem with the igniter circuit or the furnace's ground, and the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
Only some models show this code. Check the list below.
What causes it
GMS8, GMH8, GMSS9, GMH95 and GKS9 boards
-
The igniter is connected wrongly or the wiring from the control board to it is faulty.
-
The igniter has failed. A technician compares its resistance with the specification.
-
A poor unit ground or burner ground.
-
A faulty integrated control board.
GMES80, GMES92 and GMES96 boards
-
The igniter is connected wrongly or the wiring from the control board to it is faulty.
-
The igniter has failed.
-
A poor unit ground or burner ground.
-
A faulty integrated control board.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
214 models in 10 ranges
| Range | Models |
|---|---|
| GDH8 | GDH80403AN, GDH80403AX, GDH80603AN, GDH80603AX, GDH80804BN, GDH80804BX, GDH81005CN, GDH81005CX |
| GDS8 | GDS80403AN, GDS80403AX, GDS80603AN, GDS80603AX, GDS80804BN, GDS80804BX, GDS81005CN, GDS81005CX |
| GMH8 / AMH8 | GMH80403AN, GMH80403AX, GMH80603AN, GMH80603AX, GMH80604BN, GMH80604BX, GMH80803BN, GMH80803BX, GMH80804BN, GMH80804BX, GMH80805CN, GMH80805CX, GMH81005CN, GMH81005CX, GMH81205DN, GMH81205DX, GMH81405DN, AMH80403AN, AMH80403AX, AMH80603AN, AMH80603AX, AMH80604BN, AMH80604BX, AMH80803BN, AMH80803BX, AMH80804BN, AMH80804BX, AMH80805CN, AMH80805CX, AMH81005CN, AMH81005CX, AMH81205DN, AMH81205DX, AMH81405DX |
| GMH95 / GCH95 / AMH95 | GMH950453BX, GMH950703BX, GMH950704CX, GMH950904CX, GMH950905CX, GMH950905DX, GMH951155DX, AMH950453BX, AMH950703BX, AMH950704CX, AMH950904CX, AMH950905CX, AMH950905DX, AMH951155DX, GCH950453BX, GCH950703BX, GCH950704CX, GCH950905DX |
| GMS8 / AMS8 | GMS80403AN, GMS80403AX, GMS80603AN, GMS80603AX, GMS80604BN, GMS80604BX, GMS80804BN, GMS80804BX, GMS80805CN, GMS80805CX, GMS81005CN, GMS81005CX, GMS81205DN, GMS81205DX, GMS81405DN, AMS80403AX, AMS80603AX, AMS80604BX, AMS80804BX, AMS80805CX, AMS81005CX, AMS81205DX, AMS81405DN |
| GMSS92 / GCSS92 / AMSS92 | GMSS920402BN, GMSS920403AN, GMSS920603BN, GMSS920803BN, GMSS920804CN, GMSS920805CN, GMSS921004CN, GMSS921005CN, GMSS921205DN, AMSS920402BN, AMSS920403AN, AMSS920603BN, AMSS920803BN, AMSS920804CN, AMSS920805CN, AMSS921004CN, AMSS921005CN, AMSS921205DN, GCSS920402BN, GCSS920603BN, GCSS920804CN, GCSS921005CN |
| GMSS96 / GCSS96 / AMSS96 / ACSS96 | GMSS960402BN, GMSS960403AN, GMSS960603BN, GMSS960803BN, GMSS960804CN, GMSS960805CN, GMSS961005CN, GMSS961205DN, AMSS960402BN, AMSS960403AN, AMSS960603BN, AMSS960803BN, AMSS960804CN, AMSS960805CN, AMSS961005CN, AMSS961205DN, GCSS960402BN, GCSS960603BN, GCSS960804CN, GCSS961005CN, GCSS961205DN, ACSS960402BN, ACSS960603BN, ACSS960804CN, ACSS961005CN, ACSS961205DN |
| GMES80 / GCES80 / AMES80 / ACES80 | GMES800403AN, GMES800403AX, GMES800603AN, GMES800603AX, GMES800603BN, GMES800603BX, GMES800604BN, GMES800604BX, GMES800803BN, GMES800803BX, GMES800804BN, GMES800804BX, GMES800804CN, GMES800804CX, GMES800805CN, GMES800805CX, GMES801005CN, GMES801005CX, GMES801205DN, AMES800403AX, AMES800603AX, AMES800603BN, AMES800604BX, AMES800803BX, AMES800804BX, AMES800804CX, AMES800805CX, AMES801005CX, AMES801205DX, GCES800403AN, GCES800403AX, GCES800603AN, GCES800603AX, GCES800804BN, GCES800804BX, GCES801005CN, GCES801005CX, ACES800403AN, ACES800403AX, ACES800603AN, ACES800603AX, ACES800804BX, ACES801005CX |
| GMES92 | GMES920403AN, GMES920603BN, GMES920803BN, GMES920804CN, GMES920805CN, GMES921004CN, GMES921005CN, GMES921205DN |
| GMES96 / GCES96 / AMES96 / ACES96 | GMES960403AN, GMES960603BN, GMES960803BN, GMES960804CN, GMES960805CN, GMES961005CN, GMES961205DN, AMES960403AN, AMES960603BN, AMES960803BN, AMES960804CN, AMES960805CN, AMES961005CN, AMES961205DN, GCES960403BN, GCES960603BN, GCES960804CN, GCES961005CN, GCES961205DN, ACES960403BN, ACES960603BN, ACES960804CN, ACES961005CN, ACES961205DN |
Where this comes from
- GMS8/GMH8 gas furnace installation instructions (IO-446F) , page 38, 46
- GMSS92/GMSS96 gas furnace installation instructions (IOG-2009Q) , page 43
- GMH95 gas furnace installation instructions (IO-299R) , page 43
- GMES80 gas furnace installation instructions (IOG-2021H) , page 30
- GMES92/GMES96 gas furnace installation instructions (IOG-2020J) , page 41
Checked against the manufacturer's manual on 9 October 2026.
Lockout, flame lost after lighting
On GMEC96 / GCEC96 / AMEC96 / ACEC96.
The flame was proven and then lost too many times, so the furnace has locked out. The control shuts down for one hour before trying again.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
A gas supply or gas pressure problem, for example the manual gas valve outside the furnace is off.
Check the gas valve to the furnace and turn the gas back on safelyYou can do this
- Check whether the manual gas shut-off valve on the pipe outside the furnace is open. On most quarter-turn valves the handle sits in line with the pipe when open.
- If it was closed, do not just open it. Turn the gas back on using the start-up steps in your manual or on the label inside the furnace door: they set the thermostat low, turn off the power and the gas valve switch, then wait five minutes before checking for a gas smell. If you smell gas at any point, stop. Do not touch any electrical switch; leave and call your gas supplier from a neighbour's phone.
- If you are not comfortable doing the start-up steps, book a qualified servicer instead.
Reset a Goodman furnace lockout onceYou can do this
- Look through the sight glass on the blower compartment, note the colour of the status light and count the flashes. Write them down first, because cutting the power clears the code.
- Turn off the electrical power to the furnace, leave it off for more than 20 seconds, then turn it back on. Or turn the thermostat down until it stops calling for heat, wait a few seconds (no more than 20), then set it back.
- Left alone, the control also tries again by itself after one hour.
- Reset it once only. If the furnace locks out again, or locks out often, leave it off and book a qualified technician. A repeat lockout means the fault is still there. Do not keep resetting it.
-
A faulty gas valve.
-
A problem with the front cover pressure switch.
-
A dirty or faulty flame rod.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
- GMEC96 two-stage gas furnace installation instructions (IOG-2011U) , page 50, 55, 56
- Gas furnace user's information manual (HI-130) , page 6, 8
Checked against the manufacturer's manual on 27 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| E6 | Weak flame signal | Call a pro |
| E7 | Igniter circuit problem or poor ground | Call a pro |
| EE0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| EE6 | Weak flame signal | Call a pro |
| EE7 | Igniter circuit problem | Call a pro |
| EEL | Igniter circuit problem | Call a pro |
| EEn | Igniter open | Call a pro |
| amber light flashing rapidly | Weak flame signal | Call a pro |
| 1 red flash | Ignition failure or gas valve fault (depends on model) | Safe checks first, then a pro |
| 7 red flashes | Flame loss or ignition failure (depends on model) | Depends on your model |
| 11 red flashes | Ignition failure or overheat (depends on model) | Call a pro |
| 12 red flashes | Flue or venting fault / ignition failure (depends on model) | Call a pro |
See all ignition failure codes on gas furnaces across brands.
See all flame loss codes on gas furnaces across brands.