Goodman gas furnace code E7: Igniter circuit problem or poor ground

Gas furnace, Canada and United States

The control found a problem with the igniter circuit or the furnace's ground, and the furnace does not run.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.

What causes it

  1. The igniter is connected wrongly or the wiring from the control board to it is faulty.

    Book a licensed gas technician

  2. The igniter is shorted.

    Book a licensed gas technician

  3. A poor unit ground.

    Book a licensed gas technician

  4. The igniter relay on the control board is faulty.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation. A blank display means the board has no power or has failed. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

66 models in 4 ranges
RangeModels
GMVC8 / GCVC8 / AMVC8 / ACVC8GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX
GMVC96 / GCVC96 / AMVC96 / ACVC96GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN
GMVM96 / GCVM96 / AMVM96 / ACVM96GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
E0 Lockout after three failed ignition attempts Safe checks first, then a pro
E6 Weak flame signal Call a pro
E8 High-stage pressure switch closed at start of heating Call a pro
EE0 Lockout after three failed ignition attempts Safe checks first, then a pro
EE7 Igniter circuit problem Call a pro
EEL Igniter circuit problem Call a pro
EEn Igniter open Call a pro
1 red flash Ignition failure or gas valve fault (depends on model) Safe checks first, then a pro
7 red flashes Flame loss or ignition failure (depends on model) Depends on your model
8 red flashes Ignition failure or flame loss (depends on model) Depends on your model
11 red flashes Ignition failure or overheat (depends on model) Call a pro
12 red flashes Flue or venting fault / ignition failure (depends on model) Call a pro

See all ignition failure codes on gas furnaces across brands.