Goodman gas furnace code E7: Igniter circuit problem or poor ground
Gas furnace, Canada and United States
The control found a problem with the igniter circuit or the furnace's ground, and the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
The igniter is connected wrongly or the wiring from the control board to it is faulty.
-
The igniter is shorted.
-
A poor unit ground.
-
The igniter relay on the control board is faulty.
How to read this code on your unit
The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation. A blank display means the board has no power or has failed. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
66 models in 4 ranges
| Range | Models |
|---|---|
| GMVC8 / GCVC8 / AMVC8 / ACVC8 | GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX |
| GMVC96 / GCVC96 / AMVC96 / ACVC96 | GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN |
| GMVM96 / GCVM96 / AMVM96 / ACVM96 | GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX |
| GMVM97 / GCVM97 / AMVM97 / ACVM97 | GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN |
Where this comes from
- GMVC96/GCVC96 (revision AA) ComfortNet gas furnace installation instructions (IOG-2008H) , page 51, 54
- GMVC8/GCVC8 ComfortNet gas furnace installation instructions (IOG-2012C) , page 43
- GMVM97/GCVM97 (revision AA) modulating gas furnace installation instructions (IOG-2007H) , page 54
- GMVM96/GCVM96 modulating gas furnace installation instructions (IO-406E) , page 57
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| E0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| E6 | Weak flame signal | Call a pro |
| E8 | High-stage pressure switch closed at start of heating | Call a pro |
| EE0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| EE7 | Igniter circuit problem | Call a pro |
| EEL | Igniter circuit problem | Call a pro |
| EEn | Igniter open | Call a pro |
| 1 red flash | Ignition failure or gas valve fault (depends on model) | Safe checks first, then a pro |
| 7 red flashes | Flame loss or ignition failure (depends on model) | Depends on your model |
| 8 red flashes | Ignition failure or flame loss (depends on model) | Depends on your model |
| 11 red flashes | Ignition failure or overheat (depends on model) | Call a pro |
| 12 red flashes | Flue or venting fault / ignition failure (depends on model) | Call a pro |
See all ignition failure codes on gas furnaces across brands.