Error codes
| Code | Meaning | What you can do |
|---|---|---|
| b0 | Circulator blower motor not running | Call a pro |
| b1 | Lost communication with the circulator blower motor | Call a pro |
| b2 | Blower motor size does not match the shared data | Call a pro |
| b3 | Blower motor limiting its power, temperature or speed | You can often fix it |
| b4 | Blower motor tripped (lost rotor control or high current) | Safe checks first, then a pro |
| b5 | Blower motor fails to start (locked rotor) | Call a pro |
| b6 | Blower motor shut down for voltage or overheating | Call a pro |
| b7 | Blower motor lacks the data it needs to run | Call a pro |
| b9 | Low indoor airflow | You can often fix it |
| d0 | No shared data loaded on the control board | Call a pro |
| d4 | Invalid memory card data | Call a pro |
| E0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| E1 | Low-stage pressure switch closed at start of heating | Call a pro |
| E1A | Onboard return air sensor shorted | Call a pro |
| E2 | Low-stage pressure switch not closing | Safe checks first, then a pro |
| E3 | Overheat (depends on model) | Safe checks first, then a pro |
| E4 | Flame sensed with no call for heat | Safe checks first, then a pro |
| E5 | Open fuse on the control board | Call a pro |
| E6 | Weak flame signal | Call a pro |
| E7 | Igniter circuit problem or poor ground | Call a pro |
| E8 | High-stage pressure switch closed at start of heating | Call a pro |
| E9 | High-stage pressure switch not closing | Safe checks first, then a pro |
| E10 | Grounding fault or poor neutral connection | Call a pro |
| E11 | Rollout switch open | Call a pro |
| E15 | External return air sensor circuit open | Call a pro |
| E16 | External return air sensor circuit shorted | Call a pro |
| E17 | Supply air sensor circuit open | Call a pro |
| E18 | Supply air sensor circuit shorted | Call a pro |
| E19 | Onboard return air sensor unplugged | Call a pro |
| EA | Reversed polarity or poor ground | Call a pro |
| Eb0 | Circulator blower motor not running | Call a pro |
| Eb1 | Lost communication with the circulator blower motor | Call a pro |
| Eb2 | Blower motor size does not match the shared data | Call a pro |
| Eb3 | Blower motor limiting its power, temperature or speed | You can often fix it |
| Eb4 | Blower motor tripped (lost rotor control or high current) | Safe checks first, then a pro |
| Eb5 | Blower motor fails to start (locked rotor) | Call a pro |
| Eb6 | Blower motor shut down for voltage or overheating | Call a pro |
| Eb7 | Blower motor lacks the data it needs to run | Call a pro |
| Eb9 | Low indoor airflow | You can often fix it |
| Ed0 | No shared data loaded on the control board | Call a pro |
| Ed1 | Invalid shared data | Call a pro |
| EE | No power to the control board, or an internal control fault | You can often fix it |
| EE0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| EE1 | Pressure switch closed at start of heating | Call a pro |
| EE2 | Pressure switch not closing | Call a pro |
| EE3 | Primary limit switch open | Safe checks first, then a pro |
| EE4 | Flame sensed with no call for heat | Safe checks first, then a pro |
| EE5 | Open fuse on the control board | Call a pro |
| EE6 | Weak flame signal | Call a pro |
| EE7 | Igniter circuit problem | Call a pro |
| EE8 | High-stage pressure switch closed at start of heating | Call a pro |
| EE9 | High-stage pressure switch not closing | Call a pro |
| EEA | Reversed polarity or poor ground | Call a pro |
| EEb | Gas valve not powered when it should be | Call a pro |
| EEC | Gas valve powered when it should be off | Safe checks first, then a pro |
| EEd | Auxiliary limit switch open (blower compartment) | Safe checks first, then a pro |
| EEF | Auxiliary (condensate) switch open | Call a pro |
| EF | Condensate blockage (depends on model) | Call a pro |
| IdL | Idle, normal operation | You can often fix it |
| On | Normal operation | You can often fix it |
Models in this range
- GMVC960403BN
- GMVC960603BN
- GMVC960803BN
- GMVC960804CN
- GMVC961005CN
- GMVC961005DN
- GMVC961205DN
- GCVC960403BN
- GCVC960603BN
- GCVC960804CN
- GCVC961005CN
- GCVC961205DN
- AMVC960403BN
- AMVC960603BN
- AMVC960803BN
- AMVC960804CN
- AMVC961005CN
- AMVC961005DN
- AMVC961205DN
- ACVC960403BN
- ACVC960603BN
- ACVC960804CN
- ACVC961005CN
- ACVC961205DN