Goodman gas furnace code Eb4: Blower motor tripped (lost rotor control or high current)

Gas furnace, Canada and United States

The circulator blower motor has lost control of its rotor or sensed high current, and the furnace does not operate.

This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.

What causes it

  1. Abnormal loading on the motor, such as a sudden blockage of the furnace air inlet or outlet. A technician checks the filters, grilles, registers and ducts for blockages.

    Check and replace the furnace air filterYou can do this

    1. Turn off the electrical power to the furnace before you take the filter out.
      Never run the furnace without a filter in place.
    2. Find the filter. It sits outside the furnace cabinet, in a return air grille, a filter rack on the side of the furnace, or the duct next to it. If you cannot find or reach it, ask your installer.
    3. Replace a dirty disposable filter with one of the same size that meets UL900 or CAN/ULC-S111. Wash and dry a permanent filter the way its maker describes.
    4. Fit the filter so the air flows through it in the same direction as before, then turn the power back on.
    5. Check the filter at least once a month and clean or replace it when it is dirty. A dirty filter is the most common cause of a furnace not working properly.

    Clear blocked supply and return grillesYou can do this

    1. Go round the house and look at every supply register and return air grille.
    2. Move furniture, curtains, clothes, rugs or anything else that covers or blocks them.

    Book a licensed gas technician

  2. A sudden change in motor speed or torque.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the three-character display on the furnace control board, which you can see through the sight glass on the blower compartment. IdL means the furnace is idle and normal. A blank display means the board has no power or has failed.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

116 models in 7 ranges
RangeModels
GMVC8 / GCVC8 / AMVC8 / ACVC8GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX
GMVC80 / GCVC80 / AMVC80 / ACVC80GMVC800603BN, GMVC800603BX, GMVC800604BN, GMVC800604BX, GMVC800803BN, GMVC800804CN, GMVC800804CX, GMVC800805CN, GMVC800805CX, GMVC800805DN, GMVC800805DX, GMVC801005CN, GMVC801005CX, AMVC800603BN, AMVC800603BX, AMVC800604BN, AMVC800604BX, AMVC800803BN, AMVC800804CN, AMVC800804CX, AMVC800805CN, AMVC800805CX, AMVC800805DN, AMVC801005CN, AMVC801005CX
GMVC96 / GCVC96 / AMVC96 / ACVC96GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN
GRVM97 / GDVM97GRVM970603BN, GRVM970803BN, GRVM970804CN, GRVM971005CN, GRVM971205DN
GRVT80 / GDVT80GRVT800603BN, GRVT800603BX, GRVT800604BN, GRVT800604BX, GRVT800803BN, GRVT800804CN, GRVT800804CX, GRVT800805CN, GRVT800805CX, GRVT800805DN, GRVT800805DX, GRVT801005CN, GRVT801005CX, GDVT800603BX, GDVT800803BX, GDVT800805CX, GDVT801005CX
GRVT96 / GDVT96GRVT960403BN, GRVT960603BN, GRVT960803BN, GRVT960804CN, GRVT961005CN, GRVT961005DN, GRVT961205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
b0 Circulator blower motor not running Call a pro
b4 Blower motor tripped (lost rotor control or high current) Safe checks first, then a pro
b5 Blower motor fails to start (locked rotor) Call a pro
b7 Blower motor lacks the data it needs to run Call a pro
Eb0 Circulator blower motor not running Call a pro
Eb2 Blower motor size does not match the shared data Call a pro
Eb3 Blower motor limiting its power, temperature or speed You can often fix it
Eb5 Blower motor fails to start (locked rotor) Call a pro
Eb7 Blower motor lacks the data it needs to run Call a pro
EbL Blower motor drawing too little current (hard lockout) Call a pro
EbU Blower motor drawing current during pre-purge (hard lockout) Call a pro
EC Inducer motor overcurrent Call a pro

See all fan or blower fault codes on gas furnaces across brands.