Goodman gas furnace code EC: Inducer motor overcurrent

Gas furnace, Canada and United States

The control detected an overcurrent fault on the inducer motor, and the furnace does not run.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

What causes it

  1. The inducer motor is drawing too much current. A technician resets the power, checks the inducer runs properly and replaces the inducer or control board if needed.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation and a blank display means the board has no power. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

14 models in 2 ranges
RangeModels
GMVM96 / GCVM96 / AMVM96 / ACVM96GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
b0 Circulator blower motor not running Call a pro
b4 Blower motor tripped (lost rotor control or high current) Safe checks first, then a pro
b5 Blower motor fails to start (locked rotor) Call a pro
b7 Blower motor lacks the data it needs to run Call a pro
Eb0 Circulator blower motor not running Call a pro
Eb4 Blower motor tripped (lost rotor control or high current) Safe checks first, then a pro
Eb5 Blower motor fails to start (locked rotor) Call a pro
Eb7 Blower motor lacks the data it needs to run Call a pro
EbL Blower motor drawing too little current (hard lockout) Call a pro
EbU Blower motor drawing current during pre-purge (hard lockout) Call a pro
ECF Gas valve stepper motor communication error Call a pro
Ed Manual-reset rollout switch open Call a pro

See all fan or blower fault codes on gas furnaces across brands.