Error codes
| Code | Meaning | What you can do |
|---|---|---|
| b0 | Circulator blower motor not running | Call a pro |
| b1 | Lost communication with the circulator blower motor | Call a pro |
| b2 | Blower motor size does not match the shared data | Call a pro |
| b3 | Blower motor limiting its power, temperature or speed | You can often fix it |
| b4 | Blower motor tripped (lost rotor control or high current) | Safe checks first, then a pro |
| b5 | Blower motor fails to start (locked rotor) | Call a pro |
| b6 | Blower motor shut down for voltage or overheating | Call a pro |
| b7 | Blower motor lacks the data it needs to run | Call a pro |
| b9 | Low indoor airflow | You can often fix it |
| d0 | No shared data loaded on the control board | Call a pro |
| d4 | Invalid memory card data | Call a pro |
| E0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| E1 | Low-stage pressure switch closed at start of heating | Call a pro |
| E2 | Low-stage pressure switch not closing | Safe checks first, then a pro |
| E3 | Overheat (depends on model) | Safe checks first, then a pro |
| E4 | Flame sensed with no call for heat | Safe checks first, then a pro |
| E5 | Open fuse on the control board | Call a pro |
| E6 | Weak flame signal | Call a pro |
| E7 | Igniter circuit problem or poor ground | Call a pro |
| E8 | High-stage pressure switch closed at start of heating | Call a pro |
| E9 | High-stage pressure switch not closing | Safe checks first, then a pro |
| EA | Reversed polarity or poor ground | Call a pro |
| EC | Inducer motor overcurrent | Call a pro |
| Ed | Manual-reset rollout switch open | Call a pro |
| EF | Condensate blockage (depends on model) | Call a pro |
| IF | Internal control board fault | Call a pro |
| On | Normal operation | You can often fix it |
Models in this range
- GMVM960603BX
- GMVM960805CX
- GMVM961005DX
- GMVM961155DX