Goodman gas furnace code EF: Condensate blockage

Gas furnace, Canada and United States

This code means one of two things, depending on your model. Find your model family below, then read the section for it. The model number is on the rating label on the side of the unit.

Find your model family

If you haveIt means
GMVC8 / GCVC8 / AMVC8 / ACVC8, GMVC96 / GCVC96 / AMVC96 / ACVC96 Auxiliary switch open (high water in the coil drain pan)
GMVM96 / GCVM96 / AMVM96 / ACVM96, GMVM97 / GCVM97 / AMVM97 / ACVM97 Auxiliary input open (float switch or missing jumper)

Auxiliary switch open (high water in the coil drain pan)

On GMVC8 / GCVC8 / AMVC8 / ACVC8, GMVC96 / GCVC96 / AMVC96 / ACVC96.

The auxiliary switch input is open because the water level in the evaporator coil drain pan is high.

This needs an HVAC technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

Water may be leaking. Turn off the water supply to the unit if you see a leak.

What causes it

  1. High water in the evaporator coil drain pan. A technician checks the overflow pan and services the drain.

    Book a licensed air conditioning technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation. A blank display means the board has no power or has failed. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking an HVAC technician

Book a licensed air conditioning technicianHVAC technician

  1. Do not open any panels. Refrigerant circuits must only be opened by a licensed technician.
  2. Note the code, which unit shows it (indoor or outdoor), and the model numbers of both units.
  3. Book a licensed air conditioning technician and give them those details.

Models that show this code

52 models in 2 ranges
RangeModels
GMVC8 / GCVC8 / AMVC8 / ACVC8GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX
GMVC96 / GCVC96 / AMVC96 / ACVC96GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN

Where this comes from

Checked against the manufacturer's manual on 14 October 2026.

Auxiliary input open (float switch or missing jumper)

On GMVM96 / GCVM96 / AMVM96 / ACVM96, GMVM97 / GCVM97 / AMVM97 / ACVM97.

The auxiliary input on the control board is open, and the furnace does not run.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

Water may be leaking. Turn off the water supply to the unit if you see a leak.

What causes it

  1. An open circuit between the aux in and aux out terminals.

    Book a licensed gas technician

  2. The jumper across the auxiliary input is missing.

    Book a licensed gas technician

  3. A float switch on the auxiliary input has opened. A technician inspects it.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation and a blank display means the board has no power. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

14 models in 2 ranges
RangeModels
GMVM96 / GCVM96 / AMVM96 / ACVM96GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN

Where this comes from

Checked against the manufacturer's manual on 15 October 2026.

Other Goodman gas furnace codes

Code Meaning What you can do
EEE Internal control board fault Call a pro
EEF Auxiliary (condensate) switch open Call a pro
EEH Twinning error Call a pro
EEJ Inducer relay error Call a pro
EEL Igniter circuit problem Call a pro
EEn Igniter open Call a pro
IdL Idle, normal operation You can often fix it
IF Internal control board fault Call a pro
1 amber flash Low-stage heat call You can often fix it
2 amber flashes High-stage or single-stage heat call You can often fix it
3 amber flashes Second-stage heat call without first stage Safe checks first, then a pro
4 amber flashes Cooling call without a fan signal Safe checks first, then a pro