Goodman gas furnace 4 amber flashes: Cooling call without a fan signal
Gas furnace, Canada and United States
The thermostat is sending a cooling signal (Y or Ylo) without the fan signal (G), and the furnace does not run.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
What causes it
-
The thermostat wires are connected wrongly or the thermostat wiring is faulty.
-
A faulty thermostat.
Check the thermostat and the power to the furnaceYou can do this
- Check the thermostat is working and set to HEAT above the room temperature, or to COOL below it if the problem is with cooling.
- If the blower runs all the time, look at the thermostat's fan switch. ON runs the blower constantly; AUTO runs it only while heating or cooling.
- Check that the power switch for the furnace, often a switch on or near it, is turned on.
- Check the electrical panel for a tripped circuit breaker or a failed fuse for the furnace. Reset the breaker or replace the fuse. If the breaker trips again, leave it off and call a qualified servicer.
- Make sure both furnace doors are in place. A switch stops the furnace from running while the blower door is off.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
Checked against the manufacturer's manual on 9 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| b2 | Blower motor size does not match the shared data | Call a pro |
| d0 | No shared data loaded on the control board | Call a pro |
| d4 | Invalid memory card data | Call a pro |
| Eb2 | Blower motor size does not match the shared data | Call a pro |
| Ed0 | No shared data loaded on the control board | Call a pro |
| Ed1 | Invalid shared data | Call a pro |
| Ed8 | Invalid call, outdoor unit setting does not match | Call a pro |
| EEH | Twinning error | Call a pro |
| 3 amber flashes | Second-stage heat call without first stage | Safe checks first, then a pro |
| amber light flashing rapidly | Weak flame signal | Call a pro |
| 9 red flashes | Configuration error or electrical fault (depends on model) | Call a pro |
| red light flashing rapidly | Electrical fault or configuration error (depends on model) | Call a pro |
See all configuration error codes on gas furnaces across brands.