1. Home
  2. Goodman
  3. gas furnaces
  4. Code d4

Goodman gas furnace code d4: Invalid memory card data

Gas furnace, Canada and United States

The control board rejected the shared data on the memory card, so the furnace runs differently than expected or not at all.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

What causes it

  1. The shared data on the memory card is not right for the model. A technician reloads it from the correct memory card.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation. A blank display means the board has no power or has failed. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

66 models in 4 ranges
RangeModels
GMVC8 / GCVC8 / AMVC8 / ACVC8GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX
GMVC96 / GCVC96 / AMVC96 / ACVC96GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN
GMVM96 / GCVM96 / AMVM96 / ACVM96GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
b2 Blower motor size does not match the shared data Call a pro
d0 No shared data loaded on the control board Call a pro
E0 Lockout after three failed ignition attempts Safe checks first, then a pro
Eb2 Blower motor size does not match the shared data Call a pro
Ed0 No shared data loaded on the control board Call a pro
Ed1 Invalid shared data Call a pro
Ed8 Invalid call, outdoor unit setting does not match Call a pro
EEH Twinning error Call a pro
3 amber flashes Second-stage heat call without first stage Safe checks first, then a pro
4 amber flashes Cooling call without a fan signal Safe checks first, then a pro
9 red flashes Configuration error or electrical fault (depends on model) Call a pro
red light flashing rapidly Electrical fault or configuration error (depends on model) Call a pro

See all configuration error codes on gas furnaces across brands.