Goodman gas furnace 9 red flashes: Configuration error or electrical fault
Gas furnace, Canada and United States
This code means one of two things, depending on your model. Find your model family below, then read the section for it. The model number is on the rating label on the side of the unit.
Find your model family
| If you have | It means |
|---|---|
| GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96, GMSS92 / GCSS92 / AMSS92, GMSS96 / GCSS96 / AMSS96 / ACSS96 | Twinning fault |
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | Improper grounding or reversed polarity |
Twinning fault
On GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96, GMSS92 / GCSS92 / AMSS92, GMSS96 / GCSS96 / AMSS96 / ACSS96.
On furnaces installed as a twinned pair, the circulating blowers are not running together, or neither blower runs.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
Only some models show this code. Check the list below.
What causes it
-
The twin terminals of the two furnaces are not connected together by field wiring, or that wiring is broken.
-
The isolating relay is not used or is installed wrongly.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
123 models in 5 ranges
| Range | Models |
|---|---|
| GMES80 / GCES80 / AMES80 / ACES80 | GMES800403AN, GMES800403AX, GMES800603AN, GMES800603AX, GMES800603BN, GMES800603BX, GMES800604BN, GMES800604BX, GMES800803BN, GMES800803BX, GMES800804BN, GMES800804BX, GMES800804CN, GMES800804CX, GMES800805CN, GMES800805CX, GMES801005CN, GMES801005CX, GMES801205DN, AMES800403AX, AMES800603AX, AMES800603BN, AMES800604BX, AMES800803BX, AMES800804BX, AMES800804CX, AMES800805CX, AMES801005CX, AMES801205DX, GCES800403AN, GCES800403AX, GCES800603AN, GCES800603AX, GCES800804BN, GCES800804BX, GCES801005CN, GCES801005CX, ACES800403AN, ACES800403AX, ACES800603AN, ACES800603AX, ACES800804BX, ACES801005CX |
| GMES92 | GMES920403AN, GMES920603BN, GMES920803BN, GMES920804CN, GMES920805CN, GMES921004CN, GMES921005CN, GMES921205DN |
| GMES96 / GCES96 / AMES96 / ACES96 | GMES960403AN, GMES960603BN, GMES960803BN, GMES960804CN, GMES960805CN, GMES961005CN, GMES961205DN, AMES960403AN, AMES960603BN, AMES960803BN, AMES960804CN, AMES960805CN, AMES961005CN, AMES961205DN, GCES960403BN, GCES960603BN, GCES960804CN, GCES961005CN, GCES961205DN, ACES960403BN, ACES960603BN, ACES960804CN, ACES961005CN, ACES961205DN |
| GMSS92 / GCSS92 / AMSS92 | GMSS920402BN, GMSS920403AN, GMSS920603BN, GMSS920803BN, GMSS920804CN, GMSS920805CN, GMSS921004CN, GMSS921005CN, GMSS921205DN, AMSS920402BN, AMSS920403AN, AMSS920603BN, AMSS920803BN, AMSS920804CN, AMSS920805CN, AMSS921004CN, AMSS921005CN, AMSS921205DN, GCSS920402BN, GCSS920603BN, GCSS920804CN, GCSS921005CN |
| GMSS96 / GCSS96 / AMSS96 / ACSS96 | GMSS960402BN, GMSS960403AN, GMSS960603BN, GMSS960803BN, GMSS960804CN, GMSS960805CN, GMSS961005CN, GMSS961205DN, AMSS960402BN, AMSS960403AN, AMSS960603BN, AMSS960803BN, AMSS960804CN, AMSS960805CN, AMSS961005CN, AMSS961205DN, GCSS960402BN, GCSS960603BN, GCSS960804CN, GCSS961005CN, GCSS961205DN, ACSS960402BN, ACSS960603BN, ACSS960804CN, ACSS961005CN, ACSS961205DN |
Where this comes from
- GMES80 gas furnace installation instructions (IOG-2021H) , page 31
- GMES92/GMES96 gas furnace installation instructions (IOG-2020J) , page 42
- GMSS92/GMSS96 gas furnace installation instructions (IOG-2009Q) , page 43
Checked against the manufacturer's manual on 9 October 2026.
Improper grounding or reversed polarity
On GMEC96 / GCEC96 / AMEC96 / ACEC96.
The control found the furnace's 115 V supply wired with reversed polarity or improperly grounded, and the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
What causes it
-
The 115 V hot and neutral supply wires to the furnace are reversed.
-
The furnace is not properly grounded. A technician checks the hot wire reads 115 V to both ground and neutral, and the neutral 0 V to ground.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
Checked against the manufacturer's manual on 15 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| d4 | Invalid memory card data | Call a pro |
| E10 | Grounding fault or poor neutral connection | Call a pro |
| EA | Reversed polarity or poor ground | Call a pro |
| Eb2 | Blower motor size does not match the shared data | Call a pro |
| Ed0 | No shared data loaded on the control board | Call a pro |
| Ed1 | Invalid shared data | Call a pro |
| Ed8 | Invalid call, outdoor unit setting does not match | Call a pro |
| EEA | Reversed polarity or poor ground | Call a pro |
| EEH | Twinning error | Call a pro |
| 3 amber flashes | Second-stage heat call without first stage | Safe checks first, then a pro |
| 4 amber flashes | Cooling call without a fan signal | Safe checks first, then a pro |
| red light flashing rapidly | Electrical fault or configuration error (depends on model) | Call a pro |
See all configuration error codes on gas furnaces across brands.
See all electrical fault codes on gas furnaces across brands.