Goodman gas furnace code Ed: Manual-reset rollout switch open
Gas furnace, Canada and United States
The manual-reset rollout switch is open, and the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
This involves the flue or exhaust. A blocked or leaking flue can let carbon monoxide into the home.
What causes it
-
The orifice plate is out of position.
-
The heat exchanger is blocked.
-
The burners are out of alignment.
-
The heat exchanger is defective.
How to read this code on your unit
The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation and a blank display means the board has no power. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
14 models in 2 ranges
| Range | Models |
|---|---|
| GMVM96 / GCVM96 / AMVM96 / ACVM96 | GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX |
| GMVM97 / GCVM97 / AMVM97 / ACVM97 | GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN |
Where this comes from
- GMVM97/GCVM97 (revision AA) modulating gas furnace installation instructions (IOG-2007H) , page 54
- GMVM96/GCVM96 modulating gas furnace installation instructions (IO-406E) , page 53
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| E3 | Overheat (depends on model) | Safe checks first, then a pro |
| E11 | Rollout switch open | Call a pro |
| EC | Inducer motor overcurrent | Call a pro |
| ECF | Gas valve stepper motor communication error | Call a pro |
| Ed0 | No shared data loaded on the control board | Call a pro |
| Ed1 | Invalid shared data | Call a pro |
| EE3 | Primary limit switch open | Safe checks first, then a pro |
| EEd | Auxiliary limit switch open (blower compartment) | Safe checks first, then a pro |
| 4 red flashes | Overheat (depends on model) | Safe checks first, then a pro |
| 5 red flashes | Sensor fault or overheat (depends on model) | Safe checks first, then a pro |
| 6 red flashes | Overheat / flue or venting fault (depends on model) | Depends on your model |
| 11 red flashes | Ignition failure or overheat (depends on model) | Call a pro |
See all overheat codes on gas furnaces across brands.