Goodman gas furnace code Ed: Manual-reset rollout switch open

Gas furnace, Canada and United States

The manual-reset rollout switch is open, and the furnace does not run.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

This involves the flue or exhaust. A blocked or leaking flue can let carbon monoxide into the home.

What causes it

  1. The orifice plate is out of position.

    Book a licensed gas technician

  2. The heat exchanger is blocked.

    Book a licensed gas technician

  3. The burners are out of alignment.

    Book a licensed gas technician

  4. The heat exchanger is defective.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation and a blank display means the board has no power. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

14 models in 2 ranges
RangeModels
GMVM96 / GCVM96 / AMVM96 / ACVM96GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
E3 Overheat (depends on model) Safe checks first, then a pro
E11 Rollout switch open Call a pro
EC Inducer motor overcurrent Call a pro
ECF Gas valve stepper motor communication error Call a pro
Ed0 No shared data loaded on the control board Call a pro
Ed1 Invalid shared data Call a pro
EE3 Primary limit switch open Safe checks first, then a pro
EEd Auxiliary limit switch open (blower compartment) Safe checks first, then a pro
4 red flashes Overheat (depends on model) Safe checks first, then a pro
5 red flashes Sensor fault or overheat (depends on model) Safe checks first, then a pro
6 red flashes Overheat / flue or venting fault (depends on model) Depends on your model
11 red flashes Ignition failure or overheat (depends on model) Call a pro

See all overheat codes on gas furnaces across brands.