Goodman gas furnace code b6: Blower motor shut down for voltage or overheating

Gas furnace, Canada and United States

The circulator blower motor shut down because the supply voltage was too high or too low, or because its power module overheated. The furnace does not operate.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

What causes it

  1. The AC line voltage to the furnace is too high or too low for the range on the rating plate.

    Book a licensed gas technician

  2. High temperatures around the furnace.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation. A blank display means the board has no power or has failed. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

66 models in 4 ranges
RangeModels
GMVC8 / GCVC8 / AMVC8 / ACVC8GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX
GMVC96 / GCVC96 / AMVC96 / ACVC96GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN
GMVM96 / GCVM96 / AMVM96 / ACVM96GMVM960603BX, GMVM960805CX, GMVM961005DX, GMVM961155DX
GMVM97 / GCVM97 / AMVM97 / ACVM97GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
b3 Blower motor limiting its power, temperature or speed You can often fix it
b4 Blower motor tripped (lost rotor control or high current) Safe checks first, then a pro
b5 Blower motor fails to start (locked rotor) Call a pro
b7 Blower motor lacks the data it needs to run Call a pro
b9 Low indoor airflow You can often fix it
d0 No shared data loaded on the control board Call a pro
E5 Open fuse on the control board Call a pro
Eb6 Blower motor shut down for voltage or overheating Call a pro
EE No power to the control board, or an internal control fault You can often fix it
EE5 Open fuse on the control board Call a pro
light off No power to the control board Safe checks first, then a pro
10 red flashes Power supply problem or gas valve fault (depends on model) Depends on your model

See all power supply problem codes on gas furnaces across brands.