Goodman gas furnace 10 red flashes: Power supply problem or gas valve fault
Gas furnace, Canada and United States
This code means one of two things, depending on your model. Find your model family below, then read the section for it. The model number is on the rating label on the side of the unit.
Find your model family
| If you have | It means |
|---|---|
| GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96 | Control fuse open or no 24 V power to the control board |
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | Gas valve current with no call for heat |
Control fuse open or no 24 V power to the control board
On GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96.
A fuse is open and the control board has no 24 V power, so the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
What causes it
-
A high-voltage surge has blown the fuse. A technician replaces it with the power turned off.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
75 models in 3 ranges
| Range | Models |
|---|---|
| GMES80 / GCES80 / AMES80 / ACES80 | GMES800403AN, GMES800403AX, GMES800603AN, GMES800603AX, GMES800603BN, GMES800603BX, GMES800604BN, GMES800604BX, GMES800803BN, GMES800803BX, GMES800804BN, GMES800804BX, GMES800804CN, GMES800804CX, GMES800805CN, GMES800805CX, GMES801005CN, GMES801005CX, GMES801205DN, AMES800403AX, AMES800603AX, AMES800603BN, AMES800604BX, AMES800803BX, AMES800804BX, AMES800804CX, AMES800805CX, AMES801005CX, AMES801205DX, GCES800403AN, GCES800403AX, GCES800603AN, GCES800603AX, GCES800804BN, GCES800804BX, GCES801005CN, GCES801005CX, ACES800403AN, ACES800403AX, ACES800603AN, ACES800603AX, ACES800804BX, ACES801005CX |
| GMES92 | GMES920403AN, GMES920603BN, GMES920803BN, GMES920804CN, GMES920805CN, GMES921004CN, GMES921005CN, GMES921205DN |
| GMES96 / GCES96 / AMES96 / ACES96 | GMES960403AN, GMES960603BN, GMES960803BN, GMES960804CN, GMES960805CN, GMES961005CN, GMES961205DN, AMES960403AN, AMES960603BN, AMES960803BN, AMES960804CN, AMES960805CN, AMES961005CN, AMES961205DN, GCES960403BN, GCES960603BN, GCES960804CN, GCES961005CN, GCES961205DN, ACES960403BN, ACES960603BN, ACES960804CN, ACES961005CN, ACES961205DN |
Where this comes from
- GMES80 gas furnace installation instructions (IOG-2021H) , page 31
- GMES92/GMES96 gas furnace installation instructions (IOG-2020J) , page 42
Checked against the manufacturer's manual on 9 October 2026.
Gas valve current with no call for heat
On GMEC96 / GCEC96 / AMEC96 / ACEC96.
The control detected current to the gas valve when there is no call for heat, so gas may be flowing. The furnace does not run.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
An electrical short is feeding voltage to the gas valve.
Shut off the gas to the furnace, then the powerYou can do this
- Close the manual gas shut-off valve on the gas pipe outside the furnace first. If you smell gas, do not touch any electrical switch, do not use a phone in the building and do not try to light anything. Leave and call your gas supplier from a neighbour's phone.
- Only then turn off the electrical power to the furnace. Goodman says to shut the gas first whenever the furnace overheats or the gas does not shut off.
- Leave the furnace off and book a qualified servicer.
- Close the manual gas shut-off valve on the gas pipe outside the furnace first.
-
If the gas valve wiring is correct, the control board is faulty and needs replacing.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| b6 | Blower motor shut down for voltage or overheating | Call a pro |
| E5 | Open fuse on the control board | Call a pro |
| Eb6 | Blower motor shut down for voltage or overheating | Call a pro |
| ECF | Gas valve stepper motor communication error | Call a pro |
| EE | No power to the control board, or an internal control fault | You can often fix it |
| EE5 | Open fuse on the control board | Call a pro |
| EEb | Gas valve not powered when it should be | Call a pro |
| EEC | Gas valve powered when it should be off | Safe checks first, then a pro |
| light off | No power to the control board | Safe checks first, then a pro |
| 1 red flash | Ignition failure or gas valve fault (depends on model) | Safe checks first, then a pro |
| 9 red flashes | Configuration error or electrical fault (depends on model) | Call a pro |
| 11 red flashes | Ignition failure or overheat (depends on model) | Call a pro |
See all power supply problem codes on gas furnaces across brands.
See all gas valve fault codes on gas furnaces across brands.