Goodman gas furnace code EE: No power to the control board, or an internal control fault

Gas furnace, Canada and United States

The furnace display stays blank and a ComfortNet thermostat shows EE (internal fault). The control board has no 115 V or 24 V power, a fuse has blown or a breaker has tripped, or the board has an internal fault. The furnace does not run.

You can often clear this yourself. Work through the causes below in order, most likely first.

What causes it

  1. The power to the furnace is switched off, a circuit breaker has tripped or a house fuse has blown.

    Check the thermostat and the power to the furnaceYou can do this

    1. Check the thermostat is working and set to HEAT above the room temperature, or to COOL below it if the problem is with cooling.
    2. If the blower runs all the time, look at the thermostat's fan switch. ON runs the blower constantly; AUTO runs it only while heating or cooling.
    3. Check that the power switch for the furnace, often a switch on or near it, is turned on.
    4. Check the electrical panel for a tripped circuit breaker or a failed fuse for the furnace. Reset the breaker or replace the fuse.
      If the breaker trips again, leave it off and call a qualified servicer.
    5. Make sure both furnace doors are in place. A switch stops the furnace from running while the blower door is off.
  2. The blower door is off or not seated, so the door switch has cut the power.

    Same check as above: Check the thermostat and the power to the furnace

    Book a licensed gas technician

  3. The 24 V wires are loose or connected wrongly, or a short in the 115 V or 24 V wiring has blown the 3 A fuse on the control board.

    Book a licensed gas technician

  4. The integrated control board has an internal fault and needs replacing.

    Book a licensed gas technician

How to read this code on your unit

The code shows on the two-character display on the furnace control board, which you can see through the sight glass on the blower compartment. On means normal operation. A blank display means the board has no power or has failed. A ComfortNet thermostat, if fitted, shows the same codes with a short message and uses EE for an internal fault.

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

52 models in 2 ranges
RangeModels
GMVC8 / GCVC8 / AMVC8 / ACVC8GMVC80603BN, GMVC80603BX, GMVC80604BN, GMVC80604BX, GMVC80803BN, GMVC80803BX, GMVC80804CN, GMVC80804CX, GMVC80805CN, GMVC80805CX, GMVC80805DN, GMVC80805DX, GMVC81005CN, GMVC81005CX, AMVC80603BN, AMVC80603BX, AMVC80604BN, AMVC80604BX, AMVC80803BN, AMVC80803BX, AMVC80804CN, AMVC80804CX, AMVC80805CN, AMVC80805CX, AMVC80805DN, AMVC80805DX, AMVC81005CN, AMVC81005CX
GMVC96 / GCVC96 / AMVC96 / ACVC96GMVC960403BN, GMVC960603BN, GMVC960803BN, GMVC960804CN, GMVC961005CN, GMVC961005DN, GMVC961205DN, GCVC960403BN, GCVC960603BN, GCVC960804CN, GCVC961005CN, GCVC961205DN, AMVC960403BN, AMVC960603BN, AMVC960803BN, AMVC960804CN, AMVC961005CN, AMVC961005DN, AMVC961205DN, ACVC960403BN, ACVC960603BN, ACVC960804CN, ACVC961005CN, ACVC961205DN

Where this comes from

Checked against the manufacturer's manual on 27 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
b6 Blower motor shut down for voltage or overheating Call a pro
E5 Open fuse on the control board Call a pro
Eb6 Blower motor shut down for voltage or overheating Call a pro
Ed0 No shared data loaded on the control board Call a pro
Ed1 Invalid shared data Call a pro
Ed8 Invalid call, outdoor unit setting does not match Call a pro
EE0 Lockout after three failed ignition attempts Safe checks first, then a pro
EE1 Pressure switch closed at start of heating Call a pro
EE2 Pressure switch not closing Call a pro
EE5 Open fuse on the control board Call a pro
light off No power to the control board Safe checks first, then a pro
10 red flashes Power supply problem or gas valve fault (depends on model) Depends on your model

See all power supply problem codes on gas furnaces across brands.