Goodman gas furnace 1 red flash: Ignition failure or gas valve fault
Gas furnace, Canada and United States
This code means one of two things, depending on your model. Find your model family below, then read the section for it. The model number is on the rating label on the side of the unit.
Find your model family
| If you have | It means |
|---|---|
| GDH8, GDS8, GKS9, GMH8 / AMH8, GMH95 / GCH95 / AMH95, GMS8 / AMS8, GMSS92 / GCSS92 / AMSS92, GMSS96 / GCSS96 / AMSS96 / ACSS96, GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96 | Lockout after three failed ignition attempts |
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | Flame sensed when there should be none |
Lockout after three failed ignition attempts
On GDH8, GDS8, GKS9, GMH8 / AMH8, GMH95 / GCH95 / AMH95, GMS8 / AMS8, GMSS92 / GCSS92 / AMSS92, GMSS96 / GCSS96 / AMSS96 / ACSS96, GMES80 / GCES80 / AMES80 / ACES80, GMES92, GMES96 / GCES96 / AMES96 / ACES96.
The furnace could not light, or kept losing its flame, and has locked out after three tries. The control tries again by itself after one hour. On GMS8, GMH8, GDS8 and GDH8 furnaces this code also shows when the auxiliary limit has opened.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
GMS8, GMH8, GMSS9, GMH95 and GKS9 boards
-
No gas is reaching the burners, for example the manual gas valve outside the furnace is off or the gas supply was interrupted.
Check the gas valve to the furnace and turn the gas back on safelyYou can do this
- Check whether the manual gas shut-off valve on the pipe outside the furnace is open. On most quarter-turn valves the handle sits in line with the pipe when open.
- If it was closed, do not just open it. Turn the gas back on using the start-up steps in your manual or on the label inside the furnace door: they set the thermostat low, turn off the power and the gas valve switch, then wait five minutes before checking for a gas smell. If you smell gas at any point, stop. Do not touch any electrical switch; leave and call your gas supplier from a neighbour's phone.
- If you are not comfortable doing the start-up steps, book a qualified servicer instead.
Reset a Goodman furnace lockout onceYou can do this
- Look through the sight glass on the blower compartment, note the colour of the status light and count the flashes. Write them down first, because cutting the power clears the code.
- Turn off the electrical power to the furnace, leave it off for more than 20 seconds, then turn it back on. Or turn the thermostat down until it stops calling for heat, wait a few seconds (no more than 20), then set it back.
- Left alone, the control also tries again by itself after one hour.
- Reset it once only. If the furnace locks out again, or locks out often, leave it off and book a qualified technician. A repeat lockout means the fault is still there. Do not keep resetting it.
-
The igniter has failed or is out of position.
-
The flame sensor is coated, oxidised or badly connected, so the control cannot prove the flame. Cleaning the sensor is a job for a qualified servicer.
-
The flame lights and then goes out because of lazy burner flames from a restricted flue or combustion air pipe, or an inducer that is not performing properly.
-
Gas pressure or burner orifices are wrong for the furnace.
-
On GMSS9, GMH95 and GKS9 furnaces, the front cover pressure switch is stuck open or opens during the cycle. A technician checks its hose, wiring and contacts.
-
On GMS8, GMH8, GDS8 and GDH8 furnaces, the auxiliary limit has opened, from too little air across the heat exchanger (blocked filters, restrictive ducts, wrong blower speed or a failed blower) or a power cut during a heating cycle.
Check and replace the furnace air filterYou can do this
- Turn off the electrical power to the furnace before you take the filter out. Never run the furnace without a filter in place.
- Find the filter. It sits outside the furnace cabinet, in a return air grille, a filter rack on the side of the furnace, or the duct next to it. If you cannot find or reach it, ask your installer.
- Replace a dirty disposable filter with one of the same size that meets UL900 or CAN/ULC-S111. Wash and dry a permanent filter the way its maker describes.
- Fit the filter so the air flows through it in the same direction as before, then turn the power back on.
- Check the filter at least once a month and clean or replace it when it is dirty. A dirty filter is the most common cause of a furnace not working properly.
Clear blocked supply and return grillesYou can do this
- Go round the house and look at every supply register and return air grille.
- Move furniture, curtains, clothes, rugs or anything else that covers or blocks them.
- Turn off the electrical power to the furnace before you take the filter out.
GMES80, GMES92 and GMES96 boards
-
No gas is reaching the burners, for example the manual gas valve outside the furnace is off or the gas supply was interrupted.
Same check as above: Check the gas valve to the furnace and turn the gas back on safely
Same check as above: Reset a Goodman furnace lockout once
-
The igniter has failed or is out of position.
-
Burner orifices or gas pressure are wrong for the furnace.
-
The flame sensor is coated, oxidised or badly connected, so the control cannot prove the flame. Cleaning the sensor is a job for a qualified servicer.
-
The flame lights and then goes out because of lazy burner flames from a restricted flue, or an inducer that is not performing properly.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
220 models in 11 ranges
| Range | Models |
|---|---|
| GDH8 | GDH80403AN, GDH80403AX, GDH80603AN, GDH80603AX, GDH80804BN, GDH80804BX, GDH81005CN, GDH81005CX |
| GDS8 | GDS80403AN, GDS80403AX, GDS80603AN, GDS80603AX, GDS80804BN, GDS80804BX, GDS81005CN, GDS81005CX |
| GKS9 | GKS90453BX, GKS90703BX, GKS90704CX, GKS90904CX, GKS90905DX, GKS91155DX |
| GMH8 / AMH8 | GMH80403AN, GMH80403AX, GMH80603AN, GMH80603AX, GMH80604BN, GMH80604BX, GMH80803BN, GMH80803BX, GMH80804BN, GMH80804BX, GMH80805CN, GMH80805CX, GMH81005CN, GMH81005CX, GMH81205DN, GMH81205DX, GMH81405DN, AMH80403AN, AMH80403AX, AMH80603AN, AMH80603AX, AMH80604BN, AMH80604BX, AMH80803BN, AMH80803BX, AMH80804BN, AMH80804BX, AMH80805CN, AMH80805CX, AMH81005CN, AMH81005CX, AMH81205DN, AMH81205DX, AMH81405DX |
| GMH95 / GCH95 / AMH95 | GMH950453BX, GMH950703BX, GMH950704CX, GMH950904CX, GMH950905CX, GMH950905DX, GMH951155DX, AMH950453BX, AMH950703BX, AMH950704CX, AMH950904CX, AMH950905CX, AMH950905DX, AMH951155DX, GCH950453BX, GCH950703BX, GCH950704CX, GCH950905DX |
| GMS8 / AMS8 | GMS80403AN, GMS80403AX, GMS80603AN, GMS80603AX, GMS80604BN, GMS80604BX, GMS80804BN, GMS80804BX, GMS80805CN, GMS80805CX, GMS81005CN, GMS81005CX, GMS81205DN, GMS81205DX, GMS81405DN, AMS80403AX, AMS80603AX, AMS80604BX, AMS80804BX, AMS80805CX, AMS81005CX, AMS81205DX, AMS81405DN |
| GMSS92 / GCSS92 / AMSS92 | GMSS920402BN, GMSS920403AN, GMSS920603BN, GMSS920803BN, GMSS920804CN, GMSS920805CN, GMSS921004CN, GMSS921005CN, GMSS921205DN, AMSS920402BN, AMSS920403AN, AMSS920603BN, AMSS920803BN, AMSS920804CN, AMSS920805CN, AMSS921004CN, AMSS921005CN, AMSS921205DN, GCSS920402BN, GCSS920603BN, GCSS920804CN, GCSS921005CN |
| GMSS96 / GCSS96 / AMSS96 / ACSS96 | GMSS960402BN, GMSS960403AN, GMSS960603BN, GMSS960803BN, GMSS960804CN, GMSS960805CN, GMSS961005CN, GMSS961205DN, AMSS960402BN, AMSS960403AN, AMSS960603BN, AMSS960803BN, AMSS960804CN, AMSS960805CN, AMSS961005CN, AMSS961205DN, GCSS960402BN, GCSS960603BN, GCSS960804CN, GCSS961005CN, GCSS961205DN, ACSS960402BN, ACSS960603BN, ACSS960804CN, ACSS961005CN, ACSS961205DN |
| GMES80 / GCES80 / AMES80 / ACES80 | GMES800403AN, GMES800403AX, GMES800603AN, GMES800603AX, GMES800603BN, GMES800603BX, GMES800604BN, GMES800604BX, GMES800803BN, GMES800803BX, GMES800804BN, GMES800804BX, GMES800804CN, GMES800804CX, GMES800805CN, GMES800805CX, GMES801005CN, GMES801005CX, GMES801205DN, AMES800403AX, AMES800603AX, AMES800603BN, AMES800604BX, AMES800803BX, AMES800804BX, AMES800804CX, AMES800805CX, AMES801005CX, AMES801205DX, GCES800403AN, GCES800403AX, GCES800603AN, GCES800603AX, GCES800804BN, GCES800804BX, GCES801005CN, GCES801005CX, ACES800403AN, ACES800403AX, ACES800603AN, ACES800603AX, ACES800804BX, ACES801005CX |
| GMES92 | GMES920403AN, GMES920603BN, GMES920803BN, GMES920804CN, GMES920805CN, GMES921004CN, GMES921005CN, GMES921205DN |
| GMES96 / GCES96 / AMES96 / ACES96 | GMES960403AN, GMES960603BN, GMES960803BN, GMES960804CN, GMES960805CN, GMES961005CN, GMES961205DN, AMES960403AN, AMES960603BN, AMES960803BN, AMES960804CN, AMES960805CN, AMES961005CN, AMES961205DN, GCES960403BN, GCES960603BN, GCES960804CN, GCES961005CN, GCES961205DN, ACES960403BN, ACES960603BN, ACES960804CN, ACES961005CN, ACES961205DN |
Where this comes from
- GMS8/GMH8 gas furnace installation instructions (IO-446F) , page 36
- GMSS92/GMSS96 gas furnace installation instructions (IOG-2009Q) , page 41, 42
- GMH95 gas furnace installation instructions (IO-299R) , page 42
- GKS9 gas furnace installation instructions (IO-300O) , page 35
- Gas furnace user's information manual (HI-130) , page 6, 8
- GMES80 gas furnace installation instructions (IOG-2021H) , page 26, 29
- GMES92/GMES96 gas furnace installation instructions (IOG-2020J) , page 40
Checked against the manufacturer's manual on 15 October 2026.
Flame sensed when there should be none
On GMEC96 / GCEC96 / AMEC96 / ACEC96.
The control sees a flame when no flame should be present, and the furnace does not run. The gas valve may be stuck open.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
-
The gas valve is stuck open.
Shut off the gas to the furnace, then the powerYou can do this
- Close the manual gas shut-off valve on the gas pipe outside the furnace first. If you smell gas, do not touch any electrical switch, do not use a phone in the building and do not try to light anything. Leave and call your gas supplier from a neighbour's phone.
- Only then turn off the electrical power to the furnace. Goodman says to shut the gas first whenever the furnace overheats or the gas does not shut off.
- Leave the furnace off and book a qualified servicer.
- Close the manual gas shut-off valve on the gas pipe outside the furnace first.
-
The wiring to the gas valve is wrong.
-
The flame rod or its wire is shorted.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| ECF | Gas valve stepper motor communication error | Call a pro |
| EE0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| EE7 | Igniter circuit problem | Call a pro |
| EEb | Gas valve not powered when it should be | Call a pro |
| EEC | Gas valve powered when it should be off | Safe checks first, then a pro |
| EEL | Igniter circuit problem | Call a pro |
| EEn | Igniter open | Call a pro |
| 7 red flashes | Flame loss or ignition failure (depends on model) | Depends on your model |
| 8 red flashes | Ignition failure or flame loss (depends on model) | Depends on your model |
| 10 red flashes | Power supply problem or gas valve fault (depends on model) | Depends on your model |
| 11 red flashes | Ignition failure or overheat (depends on model) | Call a pro |
| 12 red flashes | Flue or venting fault / ignition failure (depends on model) | Call a pro |
See all ignition failure codes on gas furnaces across brands.
See all gas valve fault codes on gas furnaces across brands.