- Home
- Goodman
- gas furnaces
- GMVC80 / GCVC80 / AMVC80 / ACVC80
Goodman GMVC80 / GCVC80 / AMVC80 / ACVC80 error codes
Every checked code for the Goodman GMVC80 / GCVC80 / AMVC80 / ACVC80 range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| E1A | Onboard return air sensor shorted | Call a pro |
| E10 | Grounding fault or poor neutral connection | Call a pro |
| E11 | Rollout switch open | Call a pro |
| E15 | External return air sensor circuit open | Call a pro |
| E16 | External return air sensor circuit shorted | Call a pro |
| E17 | Supply air sensor circuit open | Call a pro |
| E18 | Supply air sensor circuit shorted | Call a pro |
| E19 | Onboard return air sensor unplugged | Call a pro |
| Eb0 | Circulator blower motor not running | Call a pro |
| Eb1 | Lost communication with the circulator blower motor | Call a pro |
| Eb2 | Blower motor size does not match the shared data | Call a pro |
| Eb3 | Blower motor limiting its power, temperature or speed | You can often fix it |
| Eb4 | Blower motor tripped (lost rotor control or high current) | Safe checks first, then a pro |
| Eb5 | Blower motor fails to start (locked rotor) | Call a pro |
| Eb6 | Blower motor shut down for voltage or overheating | Call a pro |
| Eb7 | Blower motor lacks the data it needs to run | Call a pro |
| Eb9 | Low indoor airflow | You can often fix it |
| Ed0 | No shared data loaded on the control board | Call a pro |
| Ed1 | Invalid shared data | Call a pro |
| EE0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| EE1 | Pressure switch closed at start of heating | Call a pro |
| EE2 | Pressure switch not closing | Call a pro |
| EE3 | Primary limit switch open | Safe checks first, then a pro |
| EE4 | Flame sensed with no call for heat | Safe checks first, then a pro |
| EE5 | Open fuse on the control board | Call a pro |
| EE6 | Weak flame signal | Call a pro |
| EE7 | Igniter circuit problem | Call a pro |
| EE8 | High-stage pressure switch closed at start of heating | Call a pro |
| EE9 | High-stage pressure switch not closing | Call a pro |
| EEA | Reversed polarity or poor ground | Call a pro |
| EEb | Gas valve not powered when it should be | Call a pro |
| EEC | Gas valve powered when it should be off | Safe checks first, then a pro |
| IdL | Idle, normal operation | You can often fix it |
Models in this range
- GMVC800603BN
- GMVC800603BX
- GMVC800604BN
- GMVC800604BX
- GMVC800803BN
- GMVC800804CN
- GMVC800804CX
- GMVC800805CN
- GMVC800805CX
- GMVC800805DN
- GMVC800805DX
- GMVC801005CN
- GMVC801005CX
- AMVC800603BN
- AMVC800603BX
- AMVC800604BN
- AMVC800604BX
- AMVC800803BN
- AMVC800804CN
- AMVC800804CX
- AMVC800805CN
- AMVC800805CX
- AMVC800805DN
- AMVC801005CN
- AMVC801005CX