Goodman gas furnace 2 green flashes: High-stage or single-stage cooling call
Gas furnace, Canada and United States
Two repeating green flashes mean normal operation with the thermostat calling for high-stage or single-stage cooling (Y and G). The same pattern shows when the fault recall button is pressed and no faults are stored.
You can often clear this yourself. Work through the causes below in order, most likely first.
What causes it
-
This is normal. If cooling seems weak, check the air filter first; dirty filters are the most common cause of poor heating or cooling.
Check and replace the furnace air filterYou can do this
- Turn off the electrical power to the furnace before you take the filter out. Never run the furnace without a filter in place.
- Find the filter. It sits outside the furnace cabinet, in a return air grille, a filter rack on the side of the furnace, or the duct next to it. If you cannot find or reach it, ask your installer.
- Replace a dirty disposable filter with one of the same size that meets UL900 or CAN/ULC-S111. Wash and dry a permanent filter the way its maker describes.
- Fit the filter so the air flows through it in the same direction as before, then turn the power back on.
- Check the filter at least once a month and clean or replace it when it is dirty. A dirty filter is the most common cause of a furnace not working properly.
- Turn off the electrical power to the furnace before you take the filter out.
How to read this code on your unit
Models that show this code
30 models in 1 range
| Range | Models |
|---|---|
| GMEC96 / GCEC96 / AMEC96 / ACEC96 | GMEC960302BN, GMEC960303AN, GMEC960402BN, GMEC960403AN, GMEC960603AN, GMEC960603BN, GMEC960803BN, GMEC960804CN, GMEC961004CN, GMEC961005CN, GMEC961205DN, AMEC960302BN, AMEC960303AN, AMEC960402BN, AMEC960403AN, AMEC960603AN, AMEC960603BN, AMEC960803BN, AMEC960804CN, AMEC961004CN, AMEC961005CN, AMEC961205DN, GCEC960403BN, GCEC960603BN, GCEC960803BN, GCEC961005CN, ACEC960403BN, ACEC960603BN, ACEC960803BN, ACEC961005CN |
Where this comes from
- GMEC96 two-stage gas furnace installation instructions (IOG-2011U) , page 50, 54, 56
- Gas furnace user's information manual (HI-130) , page 7
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| IdL | Idle, normal operation | You can often fix it |
| 1 amber flash | Low-stage heat call | You can often fix it |
| 2 amber flashes | High-stage or single-stage heat call | You can often fix it |
| 3 amber flashes | Second-stage heat call without first stage | Safe checks first, then a pro |
| 4 amber flashes | Cooling call without a fan signal | Safe checks first, then a pro |
| amber light flashing rapidly | Weak flame signal | Call a pro |
| 1 green flash | Low-stage cooling call | You can often fix it |
| green light flashing rapidly | Fan-only call | You can often fix it |
| steady green light | Standby, waiting for a call | You can often fix it |
| light off | No power to the control board | Safe checks first, then a pro |
| steady red light | Normal operation or control board internal fault (depends on model) | Depends on your model |
| On | Normal operation | You can often fix it |
See all normal operation codes on gas furnaces across brands.