- Home
- Goodman
- gas furnaces
- GM9C80 / GC9C80 / AM9C80
Goodman GM9C80 / GC9C80 / AM9C80 error codes
Every checked code for the Goodman GM9C80 / GC9C80 / AM9C80 range, with what it means and whether you can fix it yourself.
Error codes
| Code | Meaning | What you can do |
|---|---|---|
| E10 | Grounding fault or poor neutral connection | Call a pro |
| E11 | Rollout switch open | Call a pro |
| EbL | Blower motor drawing too little current (hard lockout) | Call a pro |
| EbU | Blower motor drawing current during pre-purge (hard lockout) | Call a pro |
| EE0 | Lockout after three failed ignition attempts | Safe checks first, then a pro |
| EE1 | Pressure switch closed at start of heating | Call a pro |
| EE2 | Pressure switch not closing | Call a pro |
| EE3 | Primary limit switch open | Safe checks first, then a pro |
| EE4 | Flame sensed with no call for heat | Safe checks first, then a pro |
| EE5 | Open fuse on the control board | Call a pro |
| EE6 | Weak flame signal | Call a pro |
| EE8 | High-stage pressure switch closed at start of heating | Call a pro |
| EE9 | High-stage pressure switch not closing | Call a pro |
| EEA | Reversed polarity or poor ground | Call a pro |
| EEb | Gas valve not powered when it should be | Call a pro |
| EEC | Gas valve powered when it should be off | Safe checks first, then a pro |
| EEE | Internal control board fault | Call a pro |
| EEH | Twinning error | Call a pro |
| EEJ | Inducer relay error | Call a pro |
| EEL | Igniter circuit problem | Call a pro |
| EEn | Igniter open | Call a pro |
| IdL | Idle, normal operation | You can often fix it |
Models in this range
- GM9C800403AN
- GM9C800403AX
- GM9C800603AN
- GM9C800603AX
- GM9C800603BN
- GM9C800603BX
- GM9C800803BN
- GM9C800803BX
- GM9C800804BN
- GM9C800804BX
- GM9C800804CN
- GM9C800804CX
- GM9C800805CN
- GM9C800805CX
- GM9C800805DX
- GM9C801004CN
- GM9C801005CN
- GM9C801005CX
- GM9C801205DN