1. Home
  2. Goodman
  3. gas furnaces
  4. GR9T80 / GD9T80

Goodman GR9T80 / GD9T80 error codes

Every checked code for the Goodman GR9T80 / GD9T80 range, with what it means and whether you can fix it yourself.

Error codes

Code Meaning What you can do
E10 Grounding fault or poor neutral connection Call a pro
E11 Rollout switch open Call a pro
EAF Lost communication with the R-32 refrigerant sensor Safe checks first, then a pro
EAL R-32 refrigerant leak detected Safe checks first, then a pro
EAr A2L relay fault on the control board Safe checks first, then a pro
EAS R-32 refrigerant sensor fault Safe checks first, then a pro
EbL Blower motor drawing too little current (hard lockout) Call a pro
EbU Blower motor drawing current during pre-purge (hard lockout) Call a pro
Ed8 Invalid call, outdoor unit setting does not match Call a pro
EE0 Lockout after three failed ignition attempts Safe checks first, then a pro
EE1 Pressure switch closed at start of heating Call a pro
EE2 Pressure switch not closing Call a pro
EE3 Primary limit switch open Safe checks first, then a pro
EE4 Flame sensed with no call for heat Safe checks first, then a pro
EE5 Open fuse on the control board Call a pro
EE6 Weak flame signal Call a pro
EE7 Igniter circuit problem Call a pro
EE8 High-stage pressure switch closed at start of heating Call a pro
EE9 High-stage pressure switch not closing Call a pro
EEA Reversed polarity or poor ground Call a pro
EEb Gas valve not powered when it should be Call a pro
EEC Gas valve powered when it should be off Safe checks first, then a pro
EEE Internal control board fault Call a pro
EEH Twinning error Call a pro
EEJ Inducer relay error Call a pro
EEL Igniter circuit problem Call a pro
EEn Igniter open Call a pro
IdL Idle, normal operation You can often fix it

Models in this range