Goodman gas furnace code EA2: A2L relay fault on the control board

Gas furnace, Canada and United States

The control board has detected a problem with its internal A2L relay and is running mitigation mode. It stops heating and only the blower runs.

This needs an HVAC technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.

This involves the refrigerant circuit, which only a licensed technician may open.

Only some models show this code. Check the list below.

What causes it

  1. A fault in the wiring connected to the ALARM terminal on the control board.

    Leave the furnace running while it clears a possible R-32 leakYou can do this

    1. Leave the furnace powered. In this mode it has stopped the gas heat on purpose and runs its blower at full airflow to dilute any leaked refrigerant. It also switches on a ventilation fan or alarm if one is connected.
    2. Once the sensor stops detecting refrigerant, the blower keeps running for five more minutes and then the furnace goes back to normal by itself, if there is no other fault.
    3. Book a licensed HVAC technician to look for a leak at the indoor coil and to check the R-32 sensor and its wiring.

    Book a licensed air conditioning technician

  2. If the code stays after the alarm wiring is disconnected and the power is cycled, the control board is replaced.

    Book a licensed air conditioning technician

How to read this code on your unit

The code shows on the three-character display on the furnace control board, which you can see through the sight glass on the blower compartment. IdL means the furnace is idle and normal. A blank display means the board has no power or has failed.

Booking an HVAC technician

Book a licensed air conditioning technicianHVAC technician

  1. Do not open any panels. Refrigerant circuits must only be opened by a licensed technician.
  2. Note the code, which unit shows it (indoor or outdoor), and the model numbers of both units.
  3. Book a licensed air conditioning technician and give them those details.

Models that show this code

29 models in 3 ranges
RangeModels
GRVM97 / GDVM97GRVM970603BN, GRVM970803BN, GRVM970804CN, GRVM971005CN, GRVM971205DN
GRVT80 / GDVT80GRVT800603BN, GRVT800603BX, GRVT800604BN, GRVT800604BX, GRVT800803BN, GRVT800804CN, GRVT800804CX, GRVT800805CN, GRVT800805CX, GRVT800805DN, GRVT800805DX, GRVT801005CN, GRVT801005CX, GDVT800603BX, GDVT800803BX, GDVT800805CX, GDVT801005CX
GRVT96 / GDVT96GRVT960403BN, GRVT960603BN, GRVT960803BN, GRVT960804CN, GRVT961005CN, GRVT961005DN, GRVT961205DN

Where this comes from

Checked against the manufacturer's manual on 13 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
E17 Supply air sensor circuit open Call a pro
E18 Supply air sensor circuit shorted Call a pro
E19 Onboard return air sensor unplugged Call a pro
EA Reversed polarity or poor ground Call a pro
EA0 R-32 refrigerant leak detected Safe checks first, then a pro
EA1 R-32 refrigerant sensor fault Safe checks first, then a pro
EAF Lost communication with the R-32 refrigerant sensor Safe checks first, then a pro
EAL R-32 refrigerant leak detected Safe checks first, then a pro
EAr A2L relay fault on the control board Safe checks first, then a pro
EAS R-32 refrigerant sensor fault Safe checks first, then a pro
Eb0 Circulator blower motor not running Call a pro
Eb1 Lost communication with the circulator blower motor Call a pro

See all refrigerant fault codes on gas furnaces across brands.