Goodman gas furnace code EA1: R-32 refrigerant sensor fault

Gas furnace, Canada and United States

The R-32 sensor has detected a fault in itself and the furnace is in mitigation mode. It stops heating and only the blower runs.

This needs an HVAC technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.

This involves the refrigerant circuit, which only a licensed technician may open.

Only some models show this code. Check the list below.

What causes it

  1. The R-32 sensor is faulty. A technician checks it and replaces it if needed.

    Leave the furnace running while it clears a possible R-32 leakYou can do this

    1. Leave the furnace powered. In this mode it has stopped the gas heat on purpose and runs its blower at full airflow to dilute any leaked refrigerant. It also switches on a ventilation fan or alarm if one is connected.
    2. Once the sensor stops detecting refrigerant, the blower keeps running for five more minutes and then the furnace goes back to normal by itself, if there is no other fault.
    3. Book a licensed HVAC technician to look for a leak at the indoor coil and to check the R-32 sensor and its wiring.

    Book a licensed air conditioning technician

How to read this code on your unit

The code shows on the three-character display on the furnace control board, which you can see through the sight glass on the blower compartment. IdL means the furnace is idle and normal. A blank display means the board has no power or has failed.

Booking an HVAC technician

Book a licensed air conditioning technicianHVAC technician

  1. Do not open any panels. Refrigerant circuits must only be opened by a licensed technician.
  2. Note the code, which unit shows it (indoor or outdoor), and the model numbers of both units.
  3. Book a licensed air conditioning technician and give them those details.

Models that show this code

29 models in 3 ranges
RangeModels
GRVM97 / GDVM97GRVM970603BN, GRVM970803BN, GRVM970804CN, GRVM971005CN, GRVM971205DN
GRVT80 / GDVT80GRVT800603BN, GRVT800603BX, GRVT800604BN, GRVT800604BX, GRVT800803BN, GRVT800804CN, GRVT800804CX, GRVT800805CN, GRVT800805CX, GRVT800805DN, GRVT800805DX, GRVT801005CN, GRVT801005CX, GDVT800603BX, GDVT800803BX, GDVT800805CX, GDVT801005CX
GRVT96 / GDVT96GRVT960403BN, GRVT960603BN, GRVT960803BN, GRVT960804CN, GRVT961005CN, GRVT961005DN, GRVT961205DN

Where this comes from

Checked against the manufacturer's manual on 15 October 2026.

Report a mistake on this page

Other Goodman gas furnace codes

Code Meaning What you can do
E16 External return air sensor circuit shorted Call a pro
E17 Supply air sensor circuit open Call a pro
E18 Supply air sensor circuit shorted Call a pro
E19 Onboard return air sensor unplugged Call a pro
EA Reversed polarity or poor ground Call a pro
EA0 R-32 refrigerant leak detected Safe checks first, then a pro
EA2 A2L relay fault on the control board Safe checks first, then a pro
EAF Lost communication with the R-32 refrigerant sensor Safe checks first, then a pro
EAL R-32 refrigerant leak detected Safe checks first, then a pro
EAr A2L relay fault on the control board Safe checks first, then a pro
EAS R-32 refrigerant sensor fault Safe checks first, then a pro
Eb0 Circulator blower motor not running Call a pro

See all refrigerant fault codes on gas furnaces across brands.