Goodman gas furnace code EbF: Inducer communication error
Gas furnace, Canada and United States
The control board cannot communicate with the inducer, and the furnace does not run.
This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.
Only some models show this code. Check the list below.
What causes it
-
The inducer connector or its line and neutral connections are not fully inserted, or the control board is not properly grounded.
How to read this code on your unit
The code shows on the three-character display on the furnace control board, which you can see through the sight glass on the blower compartment. IdL means the furnace is idle and normal. A blank display means the board has no power or has failed.
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
15 models in 2 ranges
| Range | Models |
|---|---|
| GMVM97 / GCVM97 / AMVM97 / ACVM97 | GMVM970603BN, GMVM970803BN, GMVM970804CN, GMVM971005CN, GMVM971205DN, AMVM970603BN, AMVM970803BN, AMVM970804CN, AMVM971005CN, AMVM971205DN |
| GRVM97 / GDVM97 | GRVM970603BN, GRVM970803BN, GRVM970804CN, GRVM971005CN, GRVM971205DN |
Where this comes from
- GMVM97/GCVM97 (revision B) modulating gas furnace installation instructions (IOG-2017H) , page 47
- GRVM97/GDVM97 modulating gas furnace installation instructions (IOG-2045A) , page 52
Checked against the manufacturer's manual on 13 October 2026.
Other Goodman gas furnace codes
| Code | Meaning | What you can do |
|---|---|---|
| b1 | Lost communication with the circulator blower motor | Call a pro |
| Eb1 | Lost communication with the circulator blower motor | Call a pro |
| Eb4 | Blower motor tripped (lost rotor control or high current) | Safe checks first, then a pro |
| Eb5 | Blower motor fails to start (locked rotor) | Call a pro |
| Eb6 | Blower motor shut down for voltage or overheating | Call a pro |
| Eb7 | Blower motor lacks the data it needs to run | Call a pro |
| Eb9 | Low indoor airflow | You can often fix it |
| EbL | Blower motor drawing too little current (hard lockout) | Call a pro |
| EbU | Blower motor drawing current during pre-purge (hard lockout) | Call a pro |
| EC | Inducer motor overcurrent | Call a pro |
| ECF | Gas valve stepper motor communication error | Call a pro |
| Ed | Manual-reset rollout switch open | Call a pro |