- Home
- Navien
- tankless water heaters
- Code E003
Navien tankless water heater code E003: Ignition failure
Tankless water heater, Canada and United States
The heater tried to light the burner and it did not light.
This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.
This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.
What causes it
Canadian and US models
-
The main gas supply valve to the heater is closed, or the gas supply is off.
Check the gas supply is onYou can do this
- Check whether your other gas appliances, such as the cooktop, are working.
- Check the gas isolation valve to the unit is open. On most quarter-turn valves the handle sits in line with the pipe when open.
- On bottled LPG, check the cylinder is not empty and the cylinder valve is open. If you smell gas, do not use switches or flames. Leave the area and call your gas emergency line.
-
A fault in the gas or ignition system that needs a technician. Suspect this when the code comes back with the gas supply on.
US models
-
The main gas supply valve to the heater is closed, or the gas supply is off.
Same check as above: Check the gas supply is on
Same check as above: Clear a Navien error code
-
The heater's gas manifold or its gas type DIP switch setting does not match the type of gas supplied.
-
A fault in the gas or ignition system that needs a technician. Suspect this when the code comes back with the gas supply on.
How to read this code on your unit
Booking a licensed gas technician
Book a licensed gas technicianlicensed gas technician
- Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
- Note the code, how often it appears, and the model and serial numbers from the rating label.
- Book a licensed gas technician and give them those details.
Models that show this code
21 models in 6 ranges
| Range | Models |
|---|---|
| NPE-A (first generation) | NPE-180A, NPE-210A, NPE-240A |
| NPE-S (first generation) | NPE-150S, NPE-180S, NPE-210S, NPE-240S |
| NPE-A2 | NPE-180A2, NPE-210A2, NPE-240A2 |
| NPE-S2 | NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2 |
| NPN-E | NPN-120E, NPN-160E, NPN-180E, NPN-199E |
| NPN-U | NPN-160U, NPN-180U, NPN-199U |
Where this comes from
- User's Information Manual, NPE-A/S condensing tankless water heaters (20026535G) , page 16
- User's Information Manual, NPE-A2/S2 condensing tankless water heaters (20049624A) , page 17
- User's Information Manual, NPN non-condensing tankless water heaters (20045995B) , page 22
Checked against the manufacturer's manual on 9 October 2026.
Other Navien tankless water heater codes
| Code | Meaning | What you can do |
|---|---|---|
| E004 | False flame detected | Safe checks first, then a pro |
| E012 | Flame lost | Safe checks first, then a pro |
| E016 | Heat exchanger overheated | Safe checks first, then a pro |
| E030 | Exhaust too hot | Safe checks first, then a pro |
| E031 | Burner overheated | Call a pro |
| E046 | Limit control fault | Call a pro |
| E047 | Exhaust temperature sensor fault | Call a pro |
| E056 | Modulating gas valve fault | Call a pro |
| E060 | Dual venturi fault | Call a pro |
| E109 | Fan motor fault | Safe checks first, then a pro |
| E110 | Abnormal air pressure (blocked vent or intake filter) | Safe checks first, then a pro |
| E127 | Air volume sensor fault | Call a pro |
See all ignition failure codes on tankless water heaters across brands.