Rinnai tankless water heater code 02: Burner did not light during freeze protection

Tankless water heater, United States

The heater tried to fire the burner to protect itself from freezing, but the burner did not light.

This needs a licensed gas or HVAC technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.

This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.

Only some models show this code. Check the list below.

What causes it

  1. A gas valve is closed, air was not purged from the gas line, or inlet gas pressure is too low.

    Check the gas supply is onYou can do this

    1. Check whether your other gas appliances, such as the cooktop, are working.
    2. Check the gas isolation valve to the unit is open. On most quarter-turn valves the handle sits in line with the pipe when open.
    3. On bottled LPG, check the cylinder is not empty and the cylinder valve is open.
      If you smell gas, do not use switches or flames. Leave the area and call your gas emergency line.

    Book a licensed gas or HVAC technician

  2. The igniter is not sparking, or the electrode or flame rod is loose, dirty or wired to the wrong rod.

    Book a licensed gas or HVAC technician

  3. Blocked burner orifices, debris or insects in the burner chamber, or build-up between the heat exchanger fins.

    Book a licensed gas or HVAC technician

How to read this code on your unit

Booking a licensed gas or HVAC technician

Book a licensed gas or HVAC technicianlicensed gas or HVAC technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas or HVAC technician and give them those details.

Models that show this code

32 models in 7 ranges
RangeModels
Commercial (KB)C199i (REU-KBD3237FFUDC-US), C199e (REU-KB3237WDC-US)
KBRU80i (REU-KB2530FFUD-US), RU80e (REU-KB2530WD-US), RU90e (REU-KBD2934WD-US), RU98i (REU-KB3237FFUD-US), RU98e (REU-KB3237WD-US)
KBDRUC80i (REU-KBD2530FFUD-US), RUC90i (REU-KBD2934FFUD-US), RUC98i (REU-KBD3237FFUD-US)
KBPRUR98i (REU-KBP3237FFUD-US), RUR98e (REU-KBP3237WD-US)
KCMRUCS65i (REU-KCM2025FFU-US), RUCS75i (REU-KCM2528FFU-US), RUS65e (REU-KCM2025W-US), RUS75e (REU-KCM2528W-US)
Luxury (VC)RL75i (REU-VC2528FFUD-US), RL75i(A) (REU-VC2528FFUD-US(A)), RL75e (REU-VC2528WD-US), RL75e(A) (REU-VC2528WD-US(A)), RL94i (REU-VC2837FFUD-US), RLX94i (REU-VC2737FFUD-US), RL94e (REU-VC2837WD-US)
Value (VC)V53e (REU-VAM1620W-US), V53De (REU-AM1620WD-US), V65i (REU-VC2025FFU-US), V65e (REU-VC2025W-US), V75i (REU-VC2528FFU-US), V75e (REU-VC2528W-US), V94i (REU-VC2837FFU-US), V94Xi (REU-VC2737FFU-US), V94e (REU-VC2837W-US)

Where this comes from

Checked against the manufacturer's manual on 9 October 2026.

Report a mistake on this page

Other Rinnai tankless water heater codes

Code Meaning What you can do
03 Power cut during bath fill You can often fix it
05 Bypass flow control failure Safe checks first, then a pro
10 Air intake, flue or condensate blockage Safe checks first, then a pro
11 No ignition Safe checks first, then a pro
12 Flame failure or low gas flow Safe checks first, then a pro
13 Combustion fault Safe checks first, then a pro
14 Overheat safety device tripped Call a pro
15 Venturi control failure Safe checks first, then a pro
16 Over-temperature shutdown Safe checks first, then a pro
17 Venturi blockage Safe checks first, then a pro
18 Gas valve adjustment limit Call a pro
19 Electrical earth fault Call a pro

See all ignition failure codes on tankless water heaters across brands.